Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(22)
ATLANTIC
(10)
AUX
(22)
BOSCH
(29)
BRYANT
(1)
Buderus
(10)
CARRIER
(31)
CIAT
(10)
COLIBRI
(1)
CONFORT AIR
(1)
Candy
(3)
DAIKIN
(120)
EQUATION
(2)
FUJI ELECTRIC
(14)
FUJITSU
(39)
Fujitsu Atlantic
(17)
GENERAL
(20)
GREE
(26)
GSS
(1)
HAIER
(108)
HEC
(1)
HEIWA
(2)
HISENSE
(68)
HITACHI
(34)
IVT
(3)
Inventor
(29)
KAYSUN
(9)
LG
(61)
MIDEA
(163)
MITSUBISHI ELECTRIC
(90)
Mitsubishi Heavy Industries
(27)
NORD
(14)
Nobu
(2)
PANASONIC
(54)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(33)
THERMOR
(10)
TOSHIBA
(59)
Viessmann
(5)
Vulcano
(4)
WESTPOINT
(5)
YORK
(7)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
Vitoclima 050-S IWAA050MFA052/Vitoclima 050-S OWAA050MFA052
Wall mounted
|
Viessmann | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.00 | 3.31 | -10° | 5.20 | 4.10 | |
|
RXF50D / FTXF50D
RXF
|
DAIKIN | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.06 | 3.71 | -15° | 5.00 | 4.60 | |
|
RAV-GM561ATP-E1/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.68 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
RXM50A9 / FNA50A9
RXM
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.77 | 4.09 | 3.33 | -10° | 5.00 | 4.00 | |
|
AIX250HIM8-2/WR525HJM8*
Wall mounted
|
RIELLO | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 3.67 | -10° | 5.35 | 4.40 | |
|
38HM18VS8C-2/42HC09JS8C*
Wall mounted
|
CIAT | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 3.67 | -10° | 5.35 | 4.40 | |
|
38QUS018D8S2*/42QHG009D8S*
Wall mounted
|
CARRIER | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 3.67 | -10° | 5.35 | 4.40 | |
|
AS 018 JDB.UI/ 1U 018 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MB3/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-BH/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MW3/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-WH/1U50S2SJ2FA-2
Super Match mono-Flair Plus
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SJ1FA-3/1U50S2SJ2FA-2
Super Match mono-Jade
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V2-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V2-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MW3/1U50KEFFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
AS50S2SF1FA-MB3/1U50KEFFRA-1
Flexis electric heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
Virtus-18K-IN/Virtus-18K-OUT
Wall mounted - Tundra Plus
|
EQUATION | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V3-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V3-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
GEH18AAXF-K6DNA1A
MONOSPLITS
|
GREE | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 3.45 | -10° | 5.20 | 4.80 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-PRE
Pearl Premium
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
AS50PDPHRA-PRE/1U50KEPFRA-H
Pearl Premium Electric Heater
|
HAIER | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
UI 5,3 kW MURAO SMART BLANC & UE MONO 5,3 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 3.80 | 4.00 | -10° | 5.30 | 4.60 | |
|
2MXM50A9 / FDXM25F9 / FDXM25F9
2MXM
|
DAIKIN | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.22 | 3.80 | 3.66 | -15° | 5.00 | 4.20 | |
|
AB50S2SC2FA-1/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
AB50S2SC2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
YDAM-050R-09M25/CDHM-050N-09M22
OASIS
|
AIRWELL | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
AB50S2SC2FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.42 | -10° | 5.00 | 4.00 | |
|
RAS-2HVRC3 / RCIM-2.0FSRE
UTOPIA PRIME
|
HITACHI | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.57 | 3.81 | 3.85 | -25° | 5.00 | 5.00 | |
|
42HU18VDS8C/38HU18VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
SC250HIDS8/AIC250HIDS8
Ceiling suspended
|
RIELLO | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
42QZL018D8S*/38QUS018D8S*
Ceiling suspended
|
CARRIER | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
Vitoclima100-SIFCAA100MFA052/Vitoclima100-SPROOFAA100MFP052
Ceiling suspended
|
Viessmann | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -10° | 5.30 | 4.00 | |
|
CU-BZ50XKE / CS-BZ50XKE
2022
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 4.70 | 4.00 | |
|
CU-UZ50WKE / CS-UZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-FZ50WKE / CS-FZ50WKE
2019
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
CU-UZ50ZKE / CS-UZ50ZKE
2023
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.42 | -15° | 5.00 | 4.00 | |
|
MXZ-3HA50VF2/MSZ-HR25VF/MSZ-HR25VF
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.02 | 3.85 | -15° | 5.00 | 3.80 | |
|
MXZ-3HA50VF3/MSZ-HR25VF2/MSZ-HR25VF2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.02 | 3.85 | -15° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.30 | 3.72 | -11° | 4.60 | 3.30 | |
|
PUZ-ZM50VKA2/PKA-M50LAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.30 | 3.72 | -11° | 4.60 | 3.30 | |
|
PUZ-ZM50VKA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.30 | 3.72 | -11° | 4.60 | 3.30 | |
|
PUZ-ZM50VKA3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.30 | 3.72 | -11° | 4.60 | 3.30 | |
|
PUZ-ZM50VKA2/SLZ-M50FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.40 | -11° | 5.00 | 3.80 | |
|
PUZ-ZM50VKA3/SLZ-M50FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.40 | -11° | 5.00 | 3.80 | |
|
AF50S2SD1FA(H)/1U50S2SJ2FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.24 | -10° | 5.00 | 3.40 | |
|
RAV-GM562ATP-E/RAV-HM561SDTY-E
DI
|
TOSHIBA | Ducted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.53 | -15° | 5.00 | 2.80 | |
|
AR40H18C1AMN/AR40H18C1AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 | |
|
AR40F18C0AMN/AR40F18C0AMX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.56 | -15° | 5.28 | 4.16 |