Filters · 4 active
Manufacturer:
BOSCH
HEIWA
SAMSUNG
AIRCLASS
(2)
AIRWELL
(26)
ATLANTIC
(16)
AUX
(6)
BRYANT
(4)
Buderus
(14)
CARRIER
(44)
CIAT
(9)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(7)
DAIKIN
(129)
EQUATION
(2)
FUJI ELECTRIC
(53)
FUJITSU
(101)
Fujitsu Atlantic
(61)
GENERAL
(89)
GREE
(38)
GSS
(2)
HAIER
(98)
HEC
(3)
HISENSE
(156)
HITACHI
(21)
IVT
(3)
Inventor
(53)
KAYSUN
(16)
LG
(115)
MIDEA
(304)
MITSUBISHI ELECTRIC
(94)
Mitsubishi Heavy Industries
(29)
NORD
(13)
Nobu
(4)
PANASONIC
(68)
RIELLO
(11)
Rotenso
(0)
THERMOR
(23)
TOSHIBA
(68)
Viessmann
(7)
Vulcano
(4)
WESTPOINT
(12)
YORK
(10)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR12TXHQASIN/AR12TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR12TXHQBWKN/AR12TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR40H12C1AMN/AR40H12C1AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40H12C1BMN/AR40H12C1BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0AMN/AR40F12C0AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0BMN/AR40F12C0BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2000 35 E / CL2000U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2001 35 E / CL2001U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
HMIS3-35-EUV1 / HMES2-35P-EUV1
ZEN3
|
HEIWA | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.70 | |
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
AR09TXHQASIN/AR09TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR09TXHQBWKN/AR09TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR40H09C1AMN/AR40H09C1AMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40H09C1BMN/AR40H09C1BMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0AMN/AR40F09C0AMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0BMN/AR40F09C0BMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AC052RXADKG/AC052RNJDKG
CAC
|
SAMSUNG | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.01 | -20° | 5.00 | 2.40 | |
|
AR50F12C1BHN/AR50F12C1BHX
RAC
|
SAMSUNG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.61 | -11° | 3.50 | 2.30 | |
|
AR50F09C1BHN/AR50F09C1BHX
RAC
|
SAMSUNG | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.64 | -11° | 2.50 | 2.10 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
AC052RXADKG/AC052TNXDKG
CAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.90 | 3.43 | -20° | 5.00 | 2.40 | |
|
HMIS3-25-EUV1 / HMES2-25P-EUV1
ZEN3
|
HEIWA | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.83 | -10° | 2.50 | 2.50 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
AC052RXADKG/AC052RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 3.90 | 3.13 | -20° | 5.00 | 2.40 | |
|
AC035RXADKG/AC035RNJDKG
CAC
|
SAMSUNG | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.07 | -20° | 3.50 | 2.00 | |
|
AR12TXFZBWKN/AR12TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.64 | -11° | 3.50 | 2.40 | |
|
AR09TXFZBWKN/AR09TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.95 | -11° | 2.50 | 2.30 | |
|
CL3000i 26 E / CL3000iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 26 E / CL3200iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
AC035RXADKG/AC035RN1DKG
CAC
|
SAMSUNG | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.12 | -20° | 3.50 | 2.00 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
CL3000i 35 E / CL3000iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3200iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
AR60F12C1KWN/AR60F12C1KWX
RAC
|
SAMSUNG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
AR70F12C1DBN/AR70F12C1DBX
RAC
|
SAMSUNG | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
AR70H12CACBN/AR70H12CACBX
RAC
|
SAMSUNG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
AC035RXADKG/AC035TNXDKG
CAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 3.31 | -20° | 3.50 | 2.10 | |
|
AR60F09C1KWN/AR60F09C1KWX
RAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AR70F09C1DBN/AR70F09C1DBX
RAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
AR70H09CACBN/AR70H09CACBX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AC026RXADKG/AC026TNXDKG
CAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.75 | -20° | 2.60 | 2.10 | |
|
AC035BXAPKG/AC035BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.13 | -25° | 3.50 | 2.00 | |
|
AR50F12C1AHN/AR50F12C1AHX
RAC
|
SAMSUNG | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.76 | -11° | 3.50 | 2.20 | |
|
AC026RXADKG/AC026RN1DKG
CAC
|
SAMSUNG | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.26 | -20° | 2.60 | 2.00 | |
|
AR50F09C1AHN/AR50F09C1AHX
RAC
|
SAMSUNG | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
CL5000L 35 E / CL5000iU 4CC 35 E
Climate 5000i L
|
BOSCH | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 |