Filters · 4 active
Manufacturer:
AIRWELL
Fujitsu Atlantic
Inventor
AIRCLASS
(0)
ATLANTIC
(6)
AUX
(18)
BOSCH
(11)
BRYANT
(0)
Buderus
(2)
CARRIER
(13)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(298)
EQUATION
(0)
FUJI ELECTRIC
(19)
FUJITSU
(49)
GENERAL
(25)
GREE
(12)
GSS
(0)
HAIER
(98)
HEC
(0)
HEIWA
(0)
HISENSE
(14)
HITACHI
(26)
IVT
(0)
KAYSUN
(10)
LG
(6)
MIDEA
(59)
MITSUBISHI ELECTRIC
(129)
Mitsubishi Heavy Industries
(37)
NORD
(4)
Nobu
(0)
PANASONIC
(16)
RIELLO
(7)
Rotenso
(0)
SAMSUNG
(27)
THERMOR
(5)
TOSHIBA
(81)
Viessmann
(6)
Vulcano
(2)
WESTPOINT
(0)
YORK
(5)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ZDAA-4090-09M25/HDLA-050N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
U5MRSL32(4)-36/LN2UVI-18WFI+LN2UVI-18WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
CDMX-070N-09M25/YDAX-070H-09M25
CDMX
|
AIRWELL | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
U7RS-24/V7CI-24WiFiR
Cassette R32
|
Inventor | Cassette | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 4.10 | -10° | 7.00 | 6.00 | |
|
AOYG30KATA/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
CDMX-100N-09M25/YDAX-100H-09T35
CDMX
|
AIRWELL | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
AOYG24KBTB/AUXG24KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.69 | -15° | 6.80 | 6.00 | |
|
YDAM-100R-09M22/CDHM-100N-09M22
OASIS
|
AIRWELL | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 9.50 | 7.20 | |
|
U5MRSL32(4)-36/AR5VI-18WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.20 | -10° | 10.50 | 8.30 | |
|
AOYG30KATA/AUXG30KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
U7iRS-24/V7CI-24WiFiR
Cassette R32
|
Inventor | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
CDMX-070N-09M25/YDAX-070H-09M25 2026
CDMX
|
AIRWELL | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.10 | 4.01 | -10° | 7.10 | 6.20 | |
|
YDAM-090R-09M22/DDHM-090N-09M22
OASIS
|
AIRWELL | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.00 | 7.00 | |
|
AOYG30KBTB/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
YDAM-100R-09M22/DDHM-100N-09M22
OASIS
|
AIRWELL | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 9.50 | 7.20 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
YDAM-100R-09M22/FDHM-100N-09M22
OASIS
|
AIRWELL | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.05 | 3.71 | -10° | 9.50 | 7.20 | |
|
AOYG24KLCA/ASYG24KLCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.00 | 3.60 | -15° | 7.10 | 7.10 | |
|
U7iRS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
U7RS-36/V7DI-36WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
AOYG24KBTB/ABYG24KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.81 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/ARXG24KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.80 | -15° | 6.80 | 6.00 | |
|
AOYG24KBTB/AUXG24KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.95 | -15° | 6.80 | 6.00 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYG30KBTB/ARXG30KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXG30KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AOYG24KBTB/ARXG24KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 4.06 | -15° | 6.80 | 6.00 | |
|
AOYG30KBTA4/ASYG07KMCC/ASYG22KMTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.10 | 3.89 | -15° | 8.00 | 6.50 | |
|
AOYG30KBTB/AUXG30KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.30 | 3.98 | -15° | 8.50 | 8.00 | |
|
DDMD-100N-09M25/YDAX-100H-09M25**
DDMD
|
AIRWELL | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
U7RS-36/V7iDI-36WiFiR
Ducted R32
|
Inventor | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
AOYH30KMTB/ASYH30KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.68 | 4.50 | 4.00 | -15° | 8.00 | 6.50 | |
|
AOYG24KMTA/ASYG24KMTE
ASY**K
|
Fujitsu Atlantic | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.19 | -15° | 7.10 | 7.10 | |
|
AOYG24KBTB/ARXH24KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.20 | 4.01 | -15° | 6.80 | 6.00 | |
|
DDMD-090N-09M25/YDAX-090H-09M25**
DDMD
|
AIRWELL | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
U7iRS-30/V7iDI-30WiFiR
Ducted R32
|
Inventor | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
AOYG36KBTA5/ASYG18KMTB/ASYG18KMTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 |