Filters · 3 active
Manufacturer:
ATLANTIC
COLIBRI
SAMSUNG
AIRCLASS
(4)
AIRWELL
(84)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR12TXHQASIN/AR12TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR12TXHQBWKN/AR12TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR40H12C1AMN/AR40H12C1AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40H12C1BMN/AR40H12C1BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0AMN/AR40F12C0AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0BMN/AR40F12C0BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AJ080TXJ4KH / AJ020TNAPKH / AJ068TNAPKH
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
AJ080TXJ4KG / AR60F07C1AW / AR70F24C1AW
FJM
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.28 | 3.80 | 3.61 | -10° | 7.45 | 5.20 | |
|
3U 024 NBB.UE/AS 012 JDB.UI+AS 012 JDB.UI
Super Match Multi
|
ATLANTIC | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 6.40 | 5.00 | |
|
AJ068TXJ3KG / AR60F07C1AW / AR70F18C1AW
FJM
|
SAMSUNG | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.85 | 3.92 | -10° | 6.50 | 5.09 | |
|
COLI12R8SHF/COLI12R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.38 | -10° | 3.68 | 2.70 | |
|
AR24BXHQASIN / AR24BXHQASIX
RAC
|
SAMSUNG | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -10° | 7.00 | 4.70 | |
|
UI 3,5KW MURAO ACCESS BLANC/UE MONO 3,5KW MURAO ACCESS BLANC
MURAO ACCESS
|
ATLANTIC | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 2.74 | -10° | 3.50 | 3.00 | |
|
4U 030 NBB.UE/AS 018 JDB.UI+AS 012 JDB.UI
Super Match Multi
|
ATLANTIC | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 7.50 | 6.50 | |
|
AB 048 DB.UI/1U 048 DC.UE
R32 Super Match Plus - Cassette
|
ATLANTIC | Cassette | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.68 | 3.93 | 2.86 | 12.30 | 8.30 | ||
|
COLI09R8SHF/COLI09R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.82 | -10° | 2.80 | 2.60 | |
|
AR09TXHQASIN/AR09TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR09TXHQBWKN/AR09TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR40H09C1AMN/AR40H09C1AMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40H09C1BMN/AR40H09C1BMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0AMN/AR40F09C0AMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0BMN/AR40F09C0BMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AC250KNHPKH / AC250KXAPNH
CAC
|
SAMSUNG | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.00 | 3.40 | 3.24 | -20° | 25.00 | 18.50 | |
|
UI 4,9KW MURAO ACCESS BLANC/UE MONO 4,9KW MURAO ACCESS BLANC
MURAO ACCESS
|
ATLANTIC | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 4.90 | 3.60 | |
|
5U 036 NBB.UE/AS 018 JDB.UI+AS 018 JDB.UI
Super Match Multi
|
ATLANTIC | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
AJ100TXJ5KH / AJ050TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.51 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
AJ100TXJ5KG / AR60F18C1AW / AR60F18C1AW
FJM
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.58 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
AB 024 DB.UI/1U 024 DC.UE
Cassettes
|
ATLANTIC | Cassette | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
UI 2,7KW MURAO ACCESS BLANC/UE MONO 2,7KW MURAO ACCESS BLANC
MURAO ACCESS
|
ATLANTIC | Wall mounted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AR40H24C1AMN/AR40H24C1AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0AMN/AR40F24C0AMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AR40F24C0BMN/AR40F24C0BMX
RAC
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.00 | -15° | 7.03 | 4.71 | |
|
AS 007 DBB.UI/ 1U 007 DBR.UE
Dojo
|
ATLANTIC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.71 | -10° | 2.05 | 1.90 | |
|
AC052RXADKG/AC052RNJDKG
CAC
|
SAMSUNG | Floor standing | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.01 | -20° | 5.00 | 2.40 | |
|
AJ068TXJ3KH / AJ025TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.02 | 4.00 | 3.82 | -10° | 6.80 | 5.09 | |
|
AS 018 DBB.UI/ 1U 018 DBRB.UE
Dojo
|
ATLANTIC | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.60 | |
|
AC200KNHPKH / AC200KXAPNH
CAC
|
SAMSUNG | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.50 | 3.45 | -20° | 20.00 | 17.50 | |
|
AC071RXADKG/AC071RNNDKG
CAC
|
SAMSUNG | Cassette | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 2.68 | -20° | 6.80 | 4.00 | |
|
COLI24R8SHF/COLI24R8SHC
Wall mounted
|
COLIBRI | Wall mounted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.00 | -10° | 7.04 | 4.80 | |
|
AB 018 DB.UI/1U 018 DC.UE
Cassettes
|
ATLANTIC | Cassette | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.42 | -10° | 5.00 | 4.00 | |
|
AS 009 DBB.UI/ 1U 009 DBRB.UE
Dojo
|
ATLANTIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.71 | -10° | 2.60 | 2.40 | |
|
AR50F12C1BHN/AR50F12C1BHX
RAC
|
SAMSUNG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.61 | -11° | 3.50 | 2.30 | |
|
AR50F09C1BHN/AR50F09C1BHX
RAC
|
SAMSUNG | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.64 | -11° | 2.50 | 2.10 | |
|
AB 036 DB.UI/1U 036 DC.UE
Cassettes
|
ATLANTIC | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -10° | 9.20 | 7.00 | |
|
AC 024 DB.UI/1U 024 DC.UE
Ceiling suspended
|
ATLANTIC | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 4.00 | 3.26 | -10° | 7.10 | 5.00 | |
|
AS 012 DBB.UI/ 1U 012 DBRB.UE
Dojo
|
ATLANTIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.71 | -10° | 3.60 | 3.20 | |
|
AC052RXADKG/AC052TNXDKG
CAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.90 | 3.43 | -20° | 5.00 | 2.40 | |
|
AR70F18C1DBN/AR70F18C1DBX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80F18CAAWN/AR80F18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 | |
|
AR80H18CAAWN/AR80H18CAAWX
RAC
|
SAMSUNG | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 3.80 | 3.53 | -11° | 5.00 | 3.80 |