Filters · 3 active
Manufacturer:
Rotenso
THERMOR
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(876)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
SAMSUNG
(208)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
IM26-NS + IM26-NS/E3U55LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 3.00 | -10° | 4.60 | 3.80 | |
|
IM35-NS + IM35-NS/E3U70LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.80 | 2.90 | -10° | 6.20 | 4.80 | |
|
IM26V2-NG + IM26V2-NG/E3U55LV2-NG-NS
MULTI -NAGANO MURALE PURE
|
THERMOR | Wall mounted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.10 | -10° | 4.80 | 4.00 | |
|
IM52-NS + IM35-NS/E4U85LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 2.90 | -10° | 7.30 | 6.30 | |
|
NAGANO CASSETTE IK26-F66-NG/E1U26LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
NAGANO CASSETTE IK35-F66-NG / E1U35LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 3.00 | |
|
IM35V2-NG + IM35V2-NG/E3U70LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 6.40 | 5.00 | |
|
NISEKO COMPACT IM20-NSC/E1U20L-NSC
NISEKO COMPACT
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.30 | -10° | 2.60 | 1.90 | |
|
IM52-NS + IM70-NS/E5U10LV2-NG-NS
MULTI-NISEKO MURALE
|
THERMOR | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.00 | -10° | 8.20 | 7.30 | |
|
NISEKO MURALE IM35-NS / E1U35L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.50 | 2.80 | |
|
NAGANO UI CASSETTE 600 x 600 5000W R32 / NAGANO U.E MONO 5200W R32
NAGANO CASSETTE
|
THERMOR | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.42 | -10° | 5.00 | 4.00 | |
|
NISEKO MURALE IM20-NS / E1U20L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
NISEKO MURALE IM26-NS / E1U26L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 2.40 | |
|
IM52V2-NG + IM35V2-NG/E4U85LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.00 | -10° | 7.50 | 6.50 | |
|
NAGANO U.I 2600W R32+NAGANO U.I 3500W R32/NAGANO U.E BI 4000W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
IM26V2-NG + IM35V2-NG/NAGANO U.E BI 4000W R32
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.10 | -10° | 4.00 | 3.30 | |
|
IM52V2-NG + IM70V2-NG/E5U10LV2-NG-NS
MULTI-NAGANO MURALE PURE
|
THERMOR | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
NISEKO MURALE IM42-NS / E1U42L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.60 | -10° | 4.80 | 3.60 | |
|
NISEKO MURALE IM52-NS / E1U52L-NS
NISEKO MURALE
|
THERMOR | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 5.00 | 4.60 | |
|
NAGANO GAINABLE MP IG71MP-NG / E1U70LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 7.10 | 5.00 | |
|
NAGANO CASSETTE IK70-F88-NG / E1U70LV2-NG
NAGANO CASSETTE
|
THERMOR | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.72 | -10° | 7.10 | 5.00 | |
|
NAGANO GAINABLE BP IG25BP-NG/E1U26LV2-NG
NAGANO GAINABLE BASSE PRESSION
|
THERMOR | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 2.50 | 2.80 | |
|
IM35V2-NG + IM35V2-NG/E2U50LV2-NG-NS
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -10° | 5.00 | 4.70 | |
|
NAGANO UI MURALE 4200W R32 / NAGANO U.E MONO 4200W R32
NAGANO MURALE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE IM42V2-NG / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE NOIRE IM42V2-NGN / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE IM42V3-NG / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO MURALE PURE NOIRE IM42V3-NGN / E1U42L-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.74 | -10° | 4.20 | 3.60 | |
|
NAGANO GAINABLE MP IG95MP-NG / E1U90LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.49 | -10° | 9.50 | 7.20 | |
|
T140Xi R16/UO140Xo R15
Tenji
|
Rotenso | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
T160Xi R16/UO160Xo R15
Tenji
|
Rotenso | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
NAGANO CONSOLE IC42V3-NG / E1U42L-NG
NAGANO CONSOLE
|
THERMOR | Console | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.00 | 3.11 | -10° | 4.20 | 3.20 | |
|
T120Xi R16/UO120Xo R14
Tenji
|
Rotenso | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
NAGANO MURALE PURE IM52V2-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V2-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM52V3-NG / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE NOIRE IM52V3-NGN / E1U52LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.20 | 4.00 | 4.00 | -10° | 5.20 | 4.60 | |
|
NAGANO MURALE PURE IM70V2-NG / E1U70LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 | |
|
NAGANO U.I 7000W R32 / E1U70LV2-NG
NAGANO MURALE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 | |
|
NAGANO MURALE PURE NOIRE IM70V2-NGN / E1U70LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 | |
|
NAGANO MURALE PURE IM70V3-NG / E1U70LV2-NG
NAGANO MURALE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 | |
|
NAGANO MURALE PURE NOIRE IM70V3-NGN / E1U70LV2-NG
NAGANO MURALE PURE
|
THERMOR | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.10 | 4.00 | 3.71 | -10° | 7.00 | 5.60 | |
|
J160Xi R14/UO160Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
J140Xi R14/UO140Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
NAGANO CONSOLE IC26V3-NG / E1U26LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.00 | 3.73 | -10° | 2.50 | 2.40 | |
|
NAGANO GAINABLE BP IG35BP-NG / E1U35LV2-NG
NAGANO GAINABLE BASSE PRESSION
|
THERMOR | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.73 | -10° | 3.50 | 3.00 | |
|
N140Xi R15/UO140Xo R15
Nevo
|
Rotenso | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
NAGANO CONSOLE IC35V3-NG / E1U35LV2-NG
NAGANO CONSOLE
|
THERMOR | Console | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.20 | 3.73 | -10° | 3.40 | 2.90 | |
|
N120Xi R15/UO120Xo R14
Nevo
|
Rotenso | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
N160Xi R15/UO160Xo R15
Nevo
|
Rotenso | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 |