Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(3)
ATLANTIC
(6)
AUX
(0)
BOSCH
(12)
BRYANT
(0)
Buderus
(4)
CARRIER
(10)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(1)
DAIKIN
(79)
EQUATION
(0)
FUJI ELECTRIC
(36)
FUJITSU
(68)
Fujitsu Atlantic
(40)
GENERAL
(61)
GREE
(11)
GSS
(1)
HAIER
(12)
HEC
(0)
HEIWA
(1)
HISENSE
(1)
HITACHI
(16)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(50)
MIDEA
(9)
MITSUBISHI ELECTRIC
(52)
Mitsubishi Heavy Industries
(29)
NORD
(1)
Nobu
(0)
PANASONIC
(55)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(29)
THERMOR
(3)
TOSHIBA
(38)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(1)
YORK
(0)
Mounting:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CU-TZ25CKE / CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.30 | 4.60 | 4.18 | -15° | 2.50 | 2.40 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
SRC20ZS-W/SRK20ZS-W
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WF
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFB
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
SRC20ZS-W/SRK20ZS-WFT
ZS-W
|
Mitsubishi Heavy Industries | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.58 | -10° | 2.00 | 2.60 | |
|
RAC-DJ25WHAE / RAK-DJ25RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 3.65 | -15° | 2.50 | 2.47 | |
|
AS07SHBHRA/1U07DEBFRA
S-MATT
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO SMART BLANC & UE MONO 2,1 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM BLANC & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM NOIR & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
S-MATT
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
AS07SHBHRA-GA-Q3/1U07DEBFRA-GA-Q3
Wall mounted - S
|
HAIER | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
CU-Z25UBEA / CS-Z25UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 4.05 | -15° | 2.50 | 2.70 | |
|
RXM25R9 / FDXM25F9
RXM
|
DAIKIN | Ducted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.40 | 2.60 | |
|
MUFZ-KW25VGHZ2/MFZ-KW25VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.10 | 4.09 | -25° | 2.50 | 3.50 | |
|
AR60F09C1AWN/AR60F09C1AWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
AR60F09CAAWN/AR60F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
MUZ-BT25VG/MSZ-BT25VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.60 | 4.20 | -15° | 2.50 | 1.90 | |
|
RAV-GM302ATP-E/RAV-HM301SDTY-E
DI
|
TOSHIBA | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.21 | 3.95 | -15° | 2.50 | 2.60 | |
|
MUZ-AY20VG/MSZ-AY20VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
MUZ-AY20VG2/MSZ-AY20VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
AR70H09CACWN/AR70H09CACWX
RAC
|
SAMSUNG | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.60 | 4.21 | -11° | 2.50 | 2.20 | |
|
ARXP20N / ATXP20N
ARXP
|
DAIKIN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.64 | 4.77 | -15° | 2.00 | 2.20 | |
|
ARXP20N9 / ATXP20N9
ARXP
|
DAIKIN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.64 | 4.77 | -15° | 2.00 | 2.20 | |
|
RAV-GM302ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.13 | 4.57 | 4.47 | -15° | 2.50 | 2.30 | |
|
AR09TXFYBWKN/AR09TXFYBWKX
RAC
|
SAMSUNG | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.74 | -11° | 2.50 | 2.30 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
MUZ-BT25VG2/MSZ-BT25VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.60 | 4.20 | -15° | 2.50 | 2.40 | |
|
AOEH09KMCG/ASEH09KMCG
ASE**K
|
FUJITSU | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYH09KMCG/ASYH09KMCG
ASY**K
|
FUJITSU | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCG
ASH**K
|
GENERAL | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
ROH09KMCG/RSH09KMCG
RS**K
|
FUJI ELECTRIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYH09KMCG/ASYH09KMCG-B
ASY**K
|
FUJITSU | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCG-B
ASH**K
|
GENERAL | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOEH09KMCG/ASEH09KMCG-B
ASE**K
|
FUJITSU | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
ROH09KMCG/RSH09KMCG-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCH-B
ASH**K
|
GENERAL | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCH
ASH**K
|
GENERAL | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYH09KMCG/ASYH09KMCG
ASY**K
|
Fujitsu Atlantic | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYH09KMCG/ASYH09KMCG-B
ASY**K
|
Fujitsu Atlantic | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
RAS-10J2AVSG-E1/RAS-B10J2FVG-E
Console
|
TOSHIBA | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.70 | 3.90 | -15° | 2.50 | 2.50 | |
|
RXP25N / FTXP25N
RXP
|
DAIKIN | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.61 | 4.36 | -15° | 2.50 | 2.40 | |
|
RXP25N9 / FTXP25N9
RXP
|
DAIKIN | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.61 | 4.36 | -15° | 2.50 | 2.40 | |
|
CU-Z25UBEA / CS-Z25UD3EAW
2017
|
PANASONIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
H09S1D NS1/H09S1D U12
U12A
|
LG | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.35 | -10° | 2.50 | 2.80 | |
|
H09S1DA NS1 / H09S1DA U12
U12A
|
LG | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.35 | -10° | 2.50 | 2.80 | |
|
AOEH07KMCG/ASEH07KMCG
ASE**K
|
FUJITSU | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOYH07KMCG/ASYH07KMCG
ASY**K
|
FUJITSU | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.00 | 2.30 | |
|
AOHH07KMCG/ASHH07KMCG
ASH**K
|
GENERAL | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.00 | 2.30 |