Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(61)
ATLANTIC
(18)
AUX
(62)
BOSCH
(56)
BRYANT
(6)
Buderus
(16)
CARRIER
(98)
CIAT
(36)
COLIBRI
(4)
CONFORT AIR
(2)
Candy
(12)
DAIKIN
(468)
EQUATION
(2)
FUJI ELECTRIC
(102)
FUJITSU
(261)
Fujitsu Atlantic
(129)
GENERAL
(134)
GREE
(58)
GSS
(4)
HAIER
(403)
HEC
(3)
HEIWA
(3)
HISENSE
(199)
HITACHI
(97)
IVT
(0)
Inventor
(109)
KAYSUN
(60)
LG
(230)
MIDEA
(611)
MITSUBISHI ELECTRIC
(310)
Mitsubishi Heavy Industries
(221)
NORD
(39)
Nobu
(8)
PANASONIC
(133)
RIELLO
(39)
Rotenso
(8)
SAMSUNG
(107)
THERMOR
(35)
TOSHIBA
(175)
Viessmann
(22)
Vulcano
(15)
WESTPOINT
(3)
YORK
(35)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
ACE-12HFN8 OUT/ACE-12HRFN8 IN
Forest
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
AF1-12HFN8(A) OUT/AF1-12HRFN8(A) IN
Forest
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
AF-12HFN8-O V1/AF-12HRFN8-I V1
Forest
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
MGPXV-12RD0-O/MGPXV-12RD0-I
Solunar
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.00 | -10° | 3.50 | 2.80 | |
|
MGPXVH-12RD0-O/MGPXV-12RD0-I
Solunar
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.00 | -10° | 3.50 | 2.80 | |
|
MOX1-12HFN8DG/MSAF-12HDN8DG
Forest
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
NBKU3VO-12/NBKU3VI-12WFI
Nobu
|
Nobu | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
GWH12ALCXB-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.90 | -10° | 3.10 | 2.70 | |
|
GWH12AGBXB-K6DNA1F
MONOSPLITS
|
GREE | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.20 | 2.70 | |
|
WIZO-12225.MH / WIZ-12225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.20 | 2.70 | |
|
GWH12AGBXB-K6DNA1I
MONOSPLITS
|
GREE | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.20 | 2.70 | |
|
HDLE-035N-09M25/YDAE-035R-09M25
Aura V2
|
AIRWELL | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.20 | 2.70 | |
|
5MWXM68A9 / FTXM50A / FTXM20A
5MWXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.74 | 3.87 | 3.21 | -15° | 6.80 | 4.50 | |
|
UU250W U80A0 / UB250 N80
UU
|
LG | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.83 | 3.79 | 23.00 | 17.60 | ||
|
5MWXM68A9 / FTXM35A / FTXM35A
5MWXM
|
DAIKIN | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.68 | 3.82 | 3.07 | -15° | 6.80 | 4.80 | |
|
AOYG12KATA/AUXG12KVLA
AUXG**K
|
FUJITSU | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
ROG12KATA/RCG12KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG12KATA/AUXG12KVLA
AUXG**K
|
GENERAL | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOEG12KATA/AUXG12KVLA
AUXG**K
|
FUJITSU | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG12KATA/AUXG12KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -15° | 3.50 | 2.80 | |
|
PUZ-M140YKA2/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 3.87 | 3.61 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA2/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 3.87 | 3.61 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA2/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 3.87 | 3.61 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA2/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 3.87 | 3.61 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA3/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 3.87 | 3.61 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA3/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 3.87 | 3.61 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA3/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 3.87 | 3.61 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA3/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.41 | 3.87 | 3.61 | -15° | 13.40 | 9.40 | |
|
RZASG140MY / FBA140A
RZASG
|
DAIKIN | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.85 | 13.40 | 7.80 | |||
|
RZASG140MV / FBA140A
RZASG
|
DAIKIN | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.82 | 3.85 | 13.40 | 7.80 | |||
|
M2OH-14HFN8-Q/MSAGAU-09HRFNX-QRD0GW+MSAGAU-09HRFNX-QRD0GW
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
M2OH-14HFN8-Q/AG2Lite-09NXD0-I+AG2Lite-09NXD0-I
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
M2OH-14HFN8-Q/MSEPBU-09HRFN8-QRD6GW+MSEPBU-09HRFN8-QRD6GW
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
M2O-14N8/MAG2-07N8+MAG2-07N8
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
M2OH-14HFN8-Q(B)/MSAGAU-09HRFNX+MSAGAU-09HRFNX
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
M2OH-14HFN8-Q/MSAGXAU-07HRDN8+MSAGXAU-07HRDN8
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
M2OH-14HFN8-Q/MSAGAU-07HRFNX-QRD0GW+MSAGAU-07HRFNX-QRD0GW
M2OH-14HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
AC-4,1 MS / AC166i.2-2,6 W + AC166i.2-2,6 W
Logacool
|
Buderus | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
UE-E3CM 41/2 / UI-L2CU M 26 + UI-L2CU M 26
Easy Cool M
|
Vulcano | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
ZDAA-2040-09M25/HDHC-025N-09M25x2
ZDAA
|
AIRWELL | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
AL-H12/4DR3HC1(U) / AUCA-H12/4DR3HB2
Y-Cassette
|
AUX | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
RXYL35M-T1B/FDCA35YB-B
Y-Cassette
|
AUX | Cassette | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.74 | -10° | 3.52 | 2.70 | |
|
MOX330U-18HFN8-QRD0W(GA)/MFA2U-17HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
MO-18N8-Q/MFAU-16NX-1
Console R32
|
MIDEA | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
U7RS-18/V7LI-18WiFiR
Console R32
|
Inventor | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
KUE-52 DVR13/KSD-52 DR14-2
ZEN Console
|
KAYSUN | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
CL5000L 53 E / CL5000iU CN 50 E
Climate 5000i L
|
BOSCH | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 | |
|
XDMX-050N-09M25/YDAX-050H-09M25
XDMX
|
AIRWELL | Console | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.50 | -10° | 5.00 | 4.00 |