Filters · 1 active
Manufacturer:
AIRCLASS
(1)
AIRWELL
(74)
ATLANTIC
(35)
AUX
(66)
BOSCH
(84)
BRYANT
(6)
Buderus
(28)
CARRIER
(124)
CIAT
(42)
COLIBRI
(5)
CONFORT AIR
(3)
Candy
(17)
DAIKIN
(677)
EQUATION
(5)
FUJI ELECTRIC
(145)
FUJITSU
(355)
Fujitsu Atlantic
(178)
GENERAL
(201)
GREE
(106)
GSS
(4)
HAIER
(533)
HEC
(5)
HEIWA
(6)
HISENSE
(273)
HITACHI
(139)
IVT
(4)
Inventor
(136)
KAYSUN
(67)
LG
(314)
MIDEA
(747)
MITSUBISHI ELECTRIC
(511)
Mitsubishi Heavy Industries
(354)
NORD
(50)
Nobu
(8)
PANASONIC
(221)
RIELLO
(45)
Rotenso
(8)
SAMSUNG
(158)
THERMOR
(58)
TOSHIBA
(238)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(15)
YORK
(38)
Mounting:
Refrigerant:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
M2OF-18HFN8-Q(H)/MFA2U-09HRFNX-QRD0W(GA)+MFA2U-09HRFNX-QRD0W(GA)
M2OF-18HFN8-Q
|
MIDEA | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
ZDAB-2050-09M25/XDMX-025N-09M25x2
ZDAB
|
AIRWELL | Console | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.60 | -10° | 5.20 | 4.50 | |
|
2AMXM50M9 / ATXM25R / ATXM25R
2AMXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
2AMXM50M9 / ATXM25A / ATXM25A
2AMXM
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.98 | -15° | 5.00 | 4.20 | |
|
FDC100VNX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDU100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDUM100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.29 | 4.13 | 4.26 | -20° | 10.00 | 11.20 | |
|
RAV-GP561ATW-E/RAV-HM561SDTY-E
SDI
|
TOSHIBA | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.23 | 3.56 | -27° | 5.00 | 3.80 | |
|
SRC50ZSX-W3/SRR50ZS-W
ZSX-W
|
Mitsubishi Heavy Industries | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.40 | 3.88 | -10° | 5.00 | 4.50 | |
|
RZAG125NV1 / FCAHG125H
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.02 | 4.53 | 12.10 | 9.52 | |||
|
AS71PEBHRA-PA/1U71WS3FRA
HAIER-PEARL PREMIUM
|
HAIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MB2/1U71WS3FRA
HAIER - FLEXIS S 24k
|
HAIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MW2/1U71WS3FRA
HAIER - FLEXIS S 24k
|
HAIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71REBHRA-RBS/1U71WS3FRA
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-MWV/1U71WEAFRA-SH
Wall mounted - S
|
HAIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
AS71SEBHRA-S/1U71WS3FRA
Wall mounted - S
|
HAIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.80 | -10° | 7.10 | 5.60 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
MUZ-AY50VG/MSZ-AY50VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
MUZ-AY50VG2/MSZ-AY50VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.70 | 3.74 | -20° | 5.00 | 4.20 | |
|
U-71PZ3E5A / S-6071PU3E
2021
|
PANASONIC | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.60 | 4.23 | -15° | 7.10 | 5.20 | |
|
PUZ-ZM71VHA2/PEAD-M71JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA2/PEAD-M71JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
PUZ-ZM71VHA3/PEAD-M71JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.30 | 4.20 | -20° | 7.10 | 4.90 | |
|
MUZ-AY35VG/MSZ-AY35VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.88 | -20° | 3.50 | 2.90 | |
|
MUZ-AY35VG2/MSZ-AY35VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.88 | -20° | 3.50 | 2.90 | |
|
UUB1 U20 / UV18FH N10
UU
|
LG | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.40 | 3.71 | -10° | 5.00 | 4.30 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
RZAG140NV1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 | |||
|
RZAG140NY1
RZAG
|
DAIKIN | Ducted | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 10.60 | 4.19 | 13.40 | 9.52 | |||
|
PUZ-ZM140VDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC100VNA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDE100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.31 | 4.41 | -20° | 10.00 | 8.50 | |
|
SRC35ZS-W2/FDTC35VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.60 | 3.70 | -10° | 3.50 | 2.90 | |
|
SUZ-M71VA/PLA-M71EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.50 | 3.61 | -10° | 7.10 | 5.80 | |
|
SUZ-M71VA2/PLA-M71EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.50 | 3.61 | -10° | 7.10 | 5.80 | |
|
5MWXM90A9 / FBA100A
5MWXM
|
DAIKIN | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.22 | 4.21 | -15° | 8.70 | 6.46 | |
|
SUZ-M35VA/MLZ-KP35VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/MLZ-KP35VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -10° | 3.50 | 2.60 | |
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
PUZ-ZM140VDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.16 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.16 | 3.90 | -20° | 13.40 | 10.60 | |
|
U-140PZH4E8 / S-1014PU3E
2023
|
PANASONIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.24 | 4.60 | 4.30 | -20° | 13.40 | 10.60 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.20 | 4.60 | 13.40 | 7.80 | |||
|
RAV-GP1101AT8-E/RAV-HM1101CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.23 | 4.46 | -20° | 10.00 | 11.60 |