Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(2)
BRYANT
(0)
Buderus
(2)
CARRIER
(2)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(8)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(8)
MIDEA
(3)
MITSUBISHI ELECTRIC
(8)
Mitsubishi Heavy Industries
(13)
NORD
(2)
Nobu
(0)
PANASONIC
(4)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(3)
THERMOR
(0)
TOSHIBA
(7)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC125VNX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.80 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 5.10 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VNX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.94 | 3.10 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDUM60VH/FDUM60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.52 | 4.60 | 2.90 | 12.50 | 14.00 | ||
|
FDC125VSX-W/FDT60VH/FDT60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.18 | 4.92 | 3.10 | 12.50 | 14.00 | ||
|
FDC125VNX-W/SRK60ZSX-W/SRK60ZSX-W
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.94 | 4.67 | 3.00 | 12.50 | 11.40 | ||
|
FDC125VSX-W/FDE60VH/FDE60VH
VNX-W/VSX-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.86 | 4.79 | 3.00 | 12.50 | 14.00 | ||
|
FDC140VNA-W/FDF71VH/FDF71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDF71VH/FDF71VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VNA-W/FDF71VH1/FDF71VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDF71VH1/FDF71VH1
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.23 | 4.98 | 3.46 | 13.60 | 10.50 | ||
|
PUZ-ZM140VDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.40 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.39 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PLA-ZM140EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PLA-ZM140EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.35 | 4.63 | 3.50 | -20° | 13.40 | 10.60 | |
|
U-50PZH3E5 / S-50PY3E
2022
|
PANASONIC | Cassette | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.37 | -20° | 4.70 | 4.50 | |
|
FDC200VSA/FDF100VD2 (x2)
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.88 | 4.51 | 3.49 | 19.00 | 12.50 | ||
|
RAS-22P2AVSG-E/RAS-B22P2KVSG-E
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.50 | -20° | 6.10 | 4.70 | |
|
RAS-22P2AVSG-E/RAS-B22P2KVSGB-E
SHORAI
|
TOSHIBA | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.60 | 3.50 | -20° | 6.10 | 4.70 | |
|
RAV-GM901ATP-E/RAV-HM901BTP-E
DI
|
TOSHIBA | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
AUC140UR4RKC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
AUC140UR4RKC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Cassette | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.50 | 3.44 | -10° | 13.50 | 9.00 | |
|
RAV-GM901ATP-E/RAV-HM901CTP-E
DI
|
TOSHIBA | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.60 | 3.40 | -15° | 8.00 | 6.30 | |
|
UUD1 U30 / UT60FH NA0
UU
|
LG | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.50 | 3.25 | 15.00 | 9.50 | ||
|
UUD3 U30 / UT60FH NA0
UU
|
LG | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.50 | 3.25 | 15.00 | 9.50 | ||
|
FDC200VSA/SRK100ZR-W/SRK100ZR-W
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.55 | 4.67 | 3.02 | 19.00 | 12.50 | ||
|
PUZ-M140VKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
PUZ-M140VKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.47 | 4.50 | 3.49 | -15° | 13.40 | 9.40 | |
|
AS35SBBHRA-MW/1U35DEBFRA-S
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MB/1U35DEBFRA-S
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MWV/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MW/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-MB/1U35DEBFRA-SH
S-MATT
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35PBBHRA-PA/1U35DEBFRA-S
HAIER-PEARL PREMIUM
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35RBBHRA-RBS/1U35DEBFRA-S
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SAT1-W/US35SAT1
NORD - S
|
NORD | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
AS35SBBHRA-S/1U35DEBFRA-S
Wall mounted - S
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.51 | 4.60 | 3.41 | -10° | 3.20 | 2.80 | |
|
RAS-18P2AVSG-E/RAS-B18J2FVG-E1
Console
|
TOSHIBA | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.00 | -20° | 5.00 | 4.00 | |
|
AR80F12CAAWN/AR80F12CAAWX
RAC
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.60 | 3.39 | -11° | 3.50 | 2.40 | |
|
AR80H12CAAWN/AR80H12CAAWX
RAC
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.60 | 3.39 | -11° | 3.50 | 2.40 | |
|
42QCE009D8SH*/38QCE009D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.30 | -10° | 3.50 | 2.60 | |
|
42QCE012D8SH*/38QCE012D8SH*
Wall mounted
|
CARRIER | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.30 | -10° | 3.52 | 2.60 | |
|
RAS-18J2AVSG-E1/RAS-B18J2FVG-E
Console
|
TOSHIBA | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 2.93 | -15° | 5.00 | 4.00 | |
|
AG-12RD6N7H-O/AG-12RD6N7-I
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX331-12HFN7-QRD6GW/MSAGBU-12HRFN7-QRD6GW(A)
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
MOX331-12HFN7-QRD6GW/MSAGBU-12HRFN7-QRD6GW(B)
Extreme save R290
|
MIDEA | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35 F
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 |