Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(6)
ATLANTIC
(6)
AUX
(0)
BOSCH
(6)
BRYANT
(1)
Buderus
(4)
CARRIER
(11)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(6)
DAIKIN
(25)
EQUATION
(1)
FUJI ELECTRIC
(33)
FUJITSU
(54)
Fujitsu Atlantic
(34)
GENERAL
(43)
GREE
(11)
GSS
(1)
HAIER
(13)
HEC
(2)
HEIWA
(1)
HISENSE
(61)
HITACHI
(2)
IVT
(0)
Inventor
(13)
KAYSUN
(3)
LG
(71)
MIDEA
(99)
MITSUBISHI ELECTRIC
(47)
Mitsubishi Heavy Industries
(5)
NORD
(3)
Nobu
(2)
PANASONIC
(19)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(36)
THERMOR
(4)
TOSHIBA
(11)
Viessmann
(3)
Vulcano
(2)
WESTPOINT
(1)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC035BXAPKG/AC035BNMPKG
CAC HEE
|
SAMSUNG | Ducted | 98 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.30 | 3.64 | -25° | 3.50 | 2.30 | |
|
AC035BXAPKG/AC035BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.30 | 3.81 | -25° | 3.50 | 2.30 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
AC035RXADKG/AC035RNNDKG
CAC
|
SAMSUNG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.33 | -20° | 3.50 | 2.10 | |
|
PUZ-ZM35VKA2/PLA-M35EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.50 | |
|
PUZ-ZM35VKA3/PEAD-M35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.20 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PEAD-M35JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.20 | 4.20 | -11° | 3.60 | 2.40 | |
|
MUZ-BT20VG/MSZ-BT20VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.10 | 4.30 | 4.55 | -15° | 2.00 | 1.50 | |
|
AC052RXADKG/AC052RNMDKG
CAC
|
SAMSUNG | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.66 | -20° | 5.00 | 2.40 | |
|
PUZ-ZM35VKA2/PEAD-M35JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PEAD-M35JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 4.50 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/SEZ-M35DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SEZ-M35DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.20 | 4.00 | -11° | 3.60 | 2.40 | |
|
MOX230-09HFN8-QRD1W(GA)/MTJ-09HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MOX230-09HFN8-Q(GA)/MTJ-09HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MO-09N8-Q/MTJU-09HNX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
KUE-26 DVR14/KPD-26 DR15
Duct R32
|
KAYSUN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
DDMD-025N-09M25/YDAX-025R-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
42QSV009D8S*/38QUS009D8SX*
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
AC052RXADKG/AC052RNNDKG
CAC
|
SAMSUNG | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.20 | 3.62 | -20° | 5.00 | 2.40 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
R32 Super Match Plus-Console
|
HAIER | Console | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
AC035RXADKG/AC035RNMDKG
CAC
|
SAMSUNG | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.48 | -20° | 3.50 | 2.00 | |
|
MUZ-AY20VG/MSZ-AY20VGK(P)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
MUZ-AY20VG2/MSZ-AY20VGK(P)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.20 | 4.17 | -20° | 2.00 | 2.30 | |
|
MOX230-09HFN8-QRD1W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
MOX230-09HFN8-Q(GA)/MFA2U-09HRFNX(GA)
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
MO-09N8-Q/MFAU-09NX-1
Console R32
|
MIDEA | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
U7RS-09/V7LI-09WiFiR
Console R32
|
Inventor | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
XDMX-025N-09M25/YDAX-025R-09M25**
XDMX
|
AIRWELL | Console | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.10 | 4.13 | -10° | 2.60 | 2.00 | |
|
MOX230-09HFN8-QRD0W(GA)/MFA2U-09HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
KUE-26 DVR14/KSD-26 DR14-2
Console R32
|
KAYSUN | Console | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 4.15 | -10° | 2.60 | 2.20 | |
|
SUZ-M25VA/MLZ-KP25VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
AOEH07KNCA/ASEH07KNCA
ASE**K
|
FUJITSU | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.40 | 4.31 | -15° | 2.00 | 2.30 | |
|
AOHH07KNCA/ASHH07KNCA
ASH**K
|
GENERAL | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.40 | 4.31 | -15° | 2.00 | 2.30 | |
|
AOYH07KNCA/ASYH07KNCA
ASY**K
|
FUJITSU | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.40 | 4.31 | -15° | 2.00 | 2.30 | |
|
ROH07KNCA/RSH07KNCA
RS**K
|
FUJI ELECTRIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.40 | 4.31 | -15° | 2.00 | 2.30 | |
|
AOHH07KNCA/ASHH07KNCH
ASH**K
|
GENERAL | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.40 | 4.31 | -15° | 2.00 | 2.30 | |
|
AOYH07KNCA/ASYH07KNCA
ASY**K
|
Fujitsu Atlantic | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.80 | 4.40 | 4.31 | -15° | 2.00 | 2.30 | |
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
MUZ-BT20VG2/MSZ-BT20VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.30 | 4.55 | -15° | 2.00 | 2.20 | |
|
MUZ-SF25VEH/MSZ-SF25VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.30 | 4.10 | -20° | 2.50 | 2.40 | |
|
SUZ-M25VA/SLZ-M25FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SLZ-M25FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
MUZ-SF25VE/MSZ-SF25VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.40 | 4.10 | -15° | 2.50 | 2.40 |