Filters
Manufacturer:
AIRCLASS
(4)
AIRWELL
(84)
ATLANTIC
(42)
AUX
(70)
BOSCH
(126)
BRYANT
(6)
Buderus
(38)
CARRIER
(149)
CIAT
(44)
COLIBRI
(6)
CONFORT AIR
(4)
Candy
(17)
DAIKIN
(882)
EQUATION
(5)
FUJI ELECTRIC
(169)
FUJITSU
(413)
Fujitsu Atlantic
(208)
GENERAL
(252)
GREE
(122)
GSS
(4)
HAIER
(579)
HEC
(5)
HEIWA
(8)
HISENSE
(343)
HITACHI
(171)
IVT
(10)
Inventor
(149)
KAYSUN
(70)
LG
(351)
MIDEA
(842)
MITSUBISHI ELECTRIC
(625)
Mitsubishi Heavy Industries
(419)
NORD
(56)
Nobu
(8)
PANASONIC
(317)
RIELLO
(47)
Rotenso
(8)
SAMSUNG
(208)
THERMOR
(58)
TOSHIBA
(315)
Viessmann
(24)
Vulcano
(16)
WESTPOINT
(22)
YORK
(39)
Mounting:
Refrigerant:
SCOP class:
SEER class:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER from:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-M250YDA/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.40 | 3.59 | 3.30 | -20° | 22.00 | 17.00 | |
|
RPIH-6.0UFE1NH/RAS-6.0UFESMH1
Primairy R32 series
|
HITACHI | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.94 | 3.70 | 3.47 | -10° | 14.19 | 12.40 | |
|
42QTD024D8S*/38QUS024D8S*
Cassette
|
CARRIER | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
42HK24VDS8C/38HU24VDS8C
Cassette
|
CIAT | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
KC270HIDS8/AIC270HIDS8
Cassette
|
RIELLO | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.05 | -10° | 7.04 | 6.00 | |
|
U-125PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
NB140CFAHRA/1N140TEAFRA-W
NORD - Cassette
|
NORD | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 2.95 | 13.00 | 9.60 | ||
|
CU-UZ35ZKE / CS-UZ35ZKE
2023
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.72 | -15° | 3.30 | 2.40 | |
|
FDC140VSX/FDU140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
MOX230-12HFN8-QRD0W(GA)/MFA2U-12HRFNX-QRD0W(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-1
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
U7RS-12/V7LI-12WiFiR
Console R32
|
Inventor | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
KUE-35 DVR13/KSD-35 DR14-2
ZEN Console
|
KAYSUN | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
XDMX-035N-09M25/YDAX-035H-09M25
XDMX
|
AIRWELL | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(GA)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MO-12N8-Q/MFAU-12NX-2
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX230-12HFN8-Q(H)/MFA2U-12HRFNX(GA)
Console R32
|
MIDEA | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
MOX630U-48HFN8-RRD0W(GA)/MCD1-48HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(GA)/MCD1-48HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MO-48N8-R-1/MCD-48NX
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-RRD0W/MCD1-48HRFNX
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(GA)/MCD2-48HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
KUE-140 DTR14/KCIS-140 DR14
Zen
|
KAYSUN | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-RRD0W(GA)/MCD1-48HRFNX-QRD0W(GA)-W
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
T140Xi R16/UO140Xo R15
Tenji
|
Rotenso | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
42QTD048D8S/38QUS048D8TX
Cassette
|
CARRIER | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(H)/MCD2-48HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
FM40AH.U34
MU
|
LG | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.30 | 12.10 | 8.60 | ||
|
FM41AH.U34
MU
|
LG | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.30 | 12.10 | 8.60 | ||
|
RXF60D9 / FTXF60D
RXF
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.06 | 3.93 | -10° | 6.00 | 4.80 | |
|
RXF60D9 / FTXF60F
RXF
|
DAIKIN | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.15 | 4.06 | 3.93 | -10° | 6.00 | 4.80 | |
|
U7iRT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
GWH24AGDXE-K6DNA1Z
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.95 | -10° | 6.20 | 4.70 | |
|
GWH24ALEXE-K6DNA2B
MONOSPLITS
|
GREE | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 6.20 | 4.70 | |
|
M3OA-18HFN8-Q/MSCB1BU-09HRFN8-QRD1GW+MSCB1BU-09HRFN8-QRD1GW
M3OA-18HFN8-Q
|
MIDEA | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.10 | -10° | 5.30 | 4.30 | |
|
AC125S2SK1FA/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK1FA(H)/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC125S2SK2FA(H)/1U125S2SN2FB
R32 Super Match Plus - Convertible
|
HAIER | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.26 | 12.40 | 8.00 | ||
|
AC 048 DB.UI/1U 048 DC.UE
R32 Super Match Plus - Convertible
|
ATLANTIC | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.86 | 3.98 | 3.21 | 12.40 | 8.00 | ||
|
NAGANO GAINABLE MP IG95MP-NG / E1U90LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.49 | -10° | 9.50 | 7.20 | |
|
MUZ-HJ50VA/MSZ-HJ50VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.20 | 3.65 | -10° | 5.00 | 3.80 | |
|
AM2-H18/4DR3C+AMWM-H09/4R3C(J*)x2
J-smart
|
AUX | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.78 | -10° | 5.30 | 4.50 | |
|
3N60WEAFRA-W/AS25SAT1-W+AS35SAT1-W
NORD - Multi
|
NORD | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.00 | -10° | 5.20 | 4.60 | |
|
FDC140VSX/FDT140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.99 | 3.81 | 14.00 | 15.50 | ||
|
AOYG14KATA/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
ROG14KATA/RCG14KVLA
RCG**K
|
FUJI ELECTRIC | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KATA/AUXG14KVLA
AUXG**K
|
GENERAL | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/AUXG14KVLA
AUXG**K
|
FUJITSU | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/AUXG14KVLA
AUXG**K
|
Fujitsu Atlantic | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.52 | -15° | 4.30 | 3.20 |