4U85S2SR5FA/AS50PDAHRA+AS35PDAHRA

HAIER - Super Match Multi

SEER
A+
SCOP
A
Certificate: 00.01.079
Model Type: AC1/A/M/R
Manufacturer: Haier Overseas Electric Appliances Corp. Ltd
Mounting: Wall mounted

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
7.30 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
5.60
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
2.75
Pc?Rated cooling capacity at standard test conditions.
7.30 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
479 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
6.30 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
3.80
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
2.90
Ph?Rated heating capacity at standard test conditions.
8.00 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
2505 kWh

Estimated Annual Running Cost

/kWh
Cooling
479 kWh/yr
Heating
2505 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
280 kWh/yr
Total
3264 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP A

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
68 dB — Loud
Indoor 1
57 dB — Moderate
Indoor 2
56 dB — Moderate

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-10.0°C
Tbiv (Bivalent Point)
-7.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
6.30 kW
COP 2.40
Ph at Tbiv?Heating capacity at the bivalent temperature.
6.30 kW
COP 2.40
TOL -10°
Tbiv -7°
-25°C -10°C (design) +7°C (rated) +20°C
Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)16.0 W
Off mode (Poffc)0.0 W
Thermostat off (Ptoc)47.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)16.0 W
Off mode (Poffh)0.0 W
Thermostat off (Ptoh)16.0 W
Crankcase heat (Pckh)0.0 W

General Specifications

Refrigerant:
R32
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
2
IU Names:
Pipe Length:
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-10.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
2.65 kW
Peh (Electrical Input Heating):
2.76 kW
Refrigerant Line:
5 m
CEE Eligible:
false