← Back to list

EZ-12RD6-O/EZ-12RD6-I

MIDEA - Solstice

SEER
A+++
SCOP
A++
Certificate: 17.04.002
Model Type: AC1/A/S/R
Manufacturer: GD MIDEA Air-Conditioning Equipment Co. Ltd
Mounting: Wall mounted

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
3.50 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
8.50
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
3.24
Pc?Rated cooling capacity at standard test conditions.
3.50 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
145 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
2.60 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.60
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
3.75
Ph?Rated heating capacity at standard test conditions.
3.81 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
791 kWh

Estimated Annual Running Cost

/kWh
Cooling
145 kWh/yr
Heating
791 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
9 kWh/yr
Total
945 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP A++ Colder A Warmer A+++

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
63 dB — Moderate
Indoor 1
57 dB — Moderate
Indoor 2

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-10.0°C
Tbiv (Bivalent Point)
-7.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
2.08 kW
COP 2.75
Ph at Tbiv?Heating capacity at the bivalent temperature.
2.30 kW
COP 2.90
TOL -10°
Tbiv -7°
-25°C -10°C (design) +7°C (rated) +20°C

Note: This unit declares colder-climate performance at −15°C (COP 2.30) despite a TOL of -10°C. The declared TOL may be conservative — the unit likely operates below it at reduced efficiency.

Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)1.0 W
Off mode (Poffc)1.0 W
Thermostat off (Ptoc)14.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)0.0 W
Off mode (Poffh)0.0 W
Thermostat off (Ptoh)0.0 W
Crankcase heat (Pckh)0.0 W
Extended Climate Zone Data

Average Climate

SCOP?Seasonal heating efficiency for the average European climate (design temp −10°C).4.60 A++
Qhe?Estimated annual electricity consumption for heating (kWh/year).791 kWh
ηs,h?Seasonal space heating energy efficiency (%). Higher is better.0%

Colder Climate

SCOP?Seasonal heating efficiency for the colder European climate (design temp −22°C).3.50 A
Pdesignh?Design heating capacity for the colder climate zone at −22°C outdoor.3.70 kW
Qhe?Estimated annual electricity consumption for heating in the colder climate zone (kWh/year).2220 kWh
ηs,h?Seasonal space heating energy efficiency for the colder climate zone (%).0%
COP @ +7°C?Heating efficiency at +7°C outdoor, 24% part load (colder climate point C).5.70
COP @ +12°C?Heating efficiency at +12°C outdoor, 11% part load (colder climate point D).7.30
Ph @ +12°C?Heating capacity at +12°C outdoor, 11% part load (colder climate).0.78 kW
Ph @ TOL?Heating capacity at the temperature operating limit (colder climate).1.70 kW

Warmer Climate

SCOP?Seasonal heating efficiency for the warmer European climate (design temp +2°C).6.00 A+++
Qhe?Estimated annual electricity consumption for heating in the warmer climate zone (kWh/year).729 kWh
ηs,h?Seasonal space heating energy efficiency for the warmer climate zone (%).0%

General Specifications

Refrigerant:
R32
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
0.5800
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
variable
Indoor Units:
IU Names:
Pipe Length:
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-10.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
1.08 kW
Peh (Electrical Input Heating):
1.02 kW
Refrigerant Line:
5
CEE Eligible:
true