PUZ-ZM140VDA/PSA-M140KA

MITSUBISHI ELECTRIC - P series

Certificate: 94.01.070
Model Type: AC2/A/S/R
Manufacturer: MITSUBISHI ELECTRIC air conditioning systems europe ltd
Mounting: Floor standing

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
13.40 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
6.34
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
3.37
Pc?Rated cooling capacity at standard test conditions.
13.40 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
0 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
10.60 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.06
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
3.00
Ph?Rated heating capacity at standard test conditions.
16.00 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
0 kWh

Estimated Annual Running Cost

/kWh
Cooling
0 kWh/yr
Heating
0 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
438 kWh/yr
Total
438 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
68 dB — Loud
Indoor 1
66 dB — Loud
Indoor 2

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-20.0°C
Tbiv (Bivalent Point)
-10.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
10.60 kW
COP 2.55
Ph at Tbiv?Heating capacity at the bivalent temperature.
10.60 kW
COP 2.55
TOL -20°
Tbiv -10°
-25°C -10°C (design) +7°C (rated) +20°C
Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)25.0 W
Off mode (Poffc)25.0 W
Thermostat off (Ptoc)55.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)25.0 W
Off mode (Poffh)25.0 W
Thermostat off (Ptoh)80.0 W
Crankcase heat (Pckh)0.0 W

General Specifications

Refrigerant:
R32
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
3.6000
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
1
IU Names:
PSA-M125KA
Pipe Length:
40.0000
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-20.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
250.6%
Seasonal Efficiency (Heating) ηs,h:
159.3%
Pec (Electrical Input Cooling):
3.98 kW
Peh (Electrical Input Heating):
5.33 kW
Refrigerant Line:
5m
CEE Eligible:
false
IU Range Names:
PSA