RAC-DJ70WHAE / RAK-DJ70RHAE

HITACHI - RAC-DJ-WHAE airHome 400

SEER
A++
SCOP
A+
Certificate: 05.01.199
Model Type: AC1/A/S/R
Manufacturer: JOHNSON CONTROLS-HITACHI AIR CONDITIONING SPAIN S.A.U.
Mounting: Wall mounted

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
7.10 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
6.20
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
2.70
Pc?Rated cooling capacity at standard test conditions.
7.10 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
399 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
5.40 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.00
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
3.10
Ph?Rated heating capacity at standard test conditions.
8.10 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
1889 kWh

Estimated Annual Running Cost

/kWh
Cooling
399 kWh/yr
Heating
1889 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
53 kWh/yr
Total
2341 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP A+ Warmer A+++

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
67 dB — Loud
Indoor 1
62 dB — Moderate
Indoor 2

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-15.0°C
Tbiv (Bivalent Point)
-7.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
5.12 kW
COP 2.18
Ph at Tbiv?Heating capacity at the bivalent temperature.
4.78 kW
COP 2.52
TOL -15°
Tbiv -7°
-25°C -10°C (design) +7°C (rated) +20°C
Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)3.0 W
Off mode (Poffc)3.0 W
Thermostat off (Ptoc)9.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)3.0 W
Off mode (Poffh)3.0 W
Thermostat off (Ptoh)9.0 W
Crankcase heat (Pckh)0.0 W
Extended Climate Zone Data

Average Climate

SCOP?Seasonal heating efficiency for the average European climate (design temp −10°C).4.00 A+
Qhe?Estimated annual electricity consumption for heating (kWh/year).1889 kWh
ηs,h?Seasonal space heating energy efficiency (%). Higher is better.0%

Warmer Climate

SCOP?Seasonal heating efficiency for the warmer European climate (design temp +2°C).5.64 A+++
Qhe?Estimated annual electricity consumption for heating in the warmer climate zone (kWh/year).723 kWh
ηs,h?Seasonal space heating energy efficiency for the warmer climate zone (%).0%

General Specifications

Refrigerant:
R32
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
1.5000
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
1
IU Names:
RAK-DJ70PHAE
Pipe Length:
5.0000
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-15.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
0.0%
Seasonal Efficiency (Heating) ηs,h:
0.0%
Pec (Electrical Input Cooling):
2.63 kW
Peh (Electrical Input Heating):
2.61 kW
Refrigerant Line:
5
CEE Eligible:
true
IU Range Names:
EV