U-140PZH4E5 / S-5010PK4E(2x)

PANASONIC - 2024

Certificate: 03.01.078
Model Type: AC2/A/M/R
Manufacturer: PANASONIC CORPORATION
Mounting: Wall mounted

Cooling Performance

Pdesignc?Design cooling capacity at 35°C outdoor, 27°C indoor, 100% load. More
13.40 kW
SEER?Seasonal Energy Efficiency Ratio - annual cooling efficiency. Higher is better. A+++ requires ≥8.5. More
6.80
EER?Energy Efficiency Ratio at 35°C outdoor (Condition A, 100% load). More
3.40
Pc?Rated cooling capacity at standard test conditions.
13.40 kW
Qce?Estimated annual electricity consumption for cooling (kWh/year).
0 kWh

Heating Performance

Pdesignh?Design heating capacity at -10°C outdoor (bivalent point). More
10.60 kW
SCOP?Seasonal Coefficient of Performance - annual heating efficiency. A+++ requires ≥5.1. More
4.31
COP?Coefficient of Performance at +7°C outdoor (standard rated conditions). More
3.71
Ph?Rated heating capacity at standard test conditions.
15.20 kW
Qhe?Estimated annual electricity consumption for heating (kWh/year).
0 kWh

Estimated Annual Running Cost

/kWh
Cooling
0 kWh/yr
Heating
0 kWh/yr
Standby?Annual standby consumption: (Psbc + Psbh) × 8760h / 1000
333 kWh/yr
Total
333 kWh/yr

Heating Partial Load

Cooling Partial Load

Efficiency Ratings

Shaded band = 25–75% range across 154 similar units; white line = peer median. Hover a bar for numbers.

Climate Zone SCOP?Average=typical European climate, Colder=Scandinavian, Warmer=Mediterranean.

SCOP

Shaded band = 25–75% range across 154 similar units; white line = peer median. Hover a bar for numbers.

Acoustic Levels (dB)?Sound power levels in dB(A). Lower is quieter. Note: sound power ≠ sound pressure. At 1m distance, sound pressure is typically 10-15 dB lower. More

Outdoor
74 dB — Loud
Indoor 1
63 dB — Moderate
Indoor 2
63 dB — Moderate

peer 25–75% range peer median · across 154 units in same class. Hover bars for numbers.

Operating Limits & Bivalent Point?TOL = manufacturer-declared minimum operating temperature (often conservative — actual capability may be lower). Tbiv = outdoor temperature below which the heat pump alone can no longer cover its rated heating output, meaning supplemental heating may be needed. More

TOL (Operating Limit)
-20.0°C
Tbiv (Bivalent Point)
-10.0°C
Ph at TOL?Heating capacity at the temperature operating limit.
8.00 kW
COP 2.00
Ph at Tbiv?Heating capacity at the bivalent temperature.
10.60 kW
COP 2.40
TOL -20°
Tbiv -10°

Shaded band shows peer p25–p75 TOL (-20.0°C to -10.0°C); thin tick is peer median (-15.0°C) across 154 similar units.

-25°C -10°C (design) +7°C (rated) +20°C
Standby & Off-Mode Power

Cooling Mode

Standby (Psbc)19.0 W
Off mode (Poffc)19.0 W
Thermostat off (Ptoc)20.0 W
Crankcase heat (Pckc)0.0 W

Heating Mode

Standby (Psbh)19.0 W
Off mode (Poffh)19.0 W
Thermostat off (Ptoh)39.0 W
Crankcase heat (Pckh)0.0 W

General Specifications

Refrigerant:
R32
Factory Charge?Pre-filled refrigerant amount. Additional charge may be needed for longer pipe runs.
3.0000
Power Supply:
230-1-50
Capacity Control?Fixed=single speed, Variable=inverter-driven modulation. More
Variable
Indoor Units:
2
IU Names:
S-5010PK4E
Pipe Length:
5.0000
TOL?Temperature Operating Limit — manufacturer-declared minimum operating temperature. Often conservative; the unit may operate below this. More
-20.0°C
Full Specifications
Seasonal Efficiency (Cooling) ηs,c:
269.0%
Seasonal Efficiency (Heating) ηs,h:
169.4%
Pec (Electrical Input Cooling):
3.94 kW
Peh (Electrical Input Heating):
4.10 kW
Refrigerant Line:
5
Cd?Degradation coefficient for cycling losses.
0.25
CEE Eligible:
false
IU Range Names:
PK4E