Filters · 4 active
Manufacturer:
AIRCLASS
CIAT
Vulcano
AIRWELL
(12)
ATLANTIC
(3)
AUX
(12)
BOSCH
(13)
BRYANT
(0)
Buderus
(1)
CARRIER
(13)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(93)
EQUATION
(0)
FUJI ELECTRIC
(23)
FUJITSU
(68)
Fujitsu Atlantic
(29)
GENERAL
(27)
GREE
(13)
GSS
(0)
HAIER
(43)
HEC
(0)
HEIWA
(0)
HISENSE
(15)
HITACHI
(50)
IVT
(0)
Inventor
(10)
KAYSUN
(13)
LG
(27)
MIDEA
(66)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(107)
NORD
(4)
Nobu
(0)
PANASONIC
(26)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(22)
THERMOR
(2)
TOSHIBA
(41)
Viessmann
(8)
WESTPOINT
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
COP from:
COP up to:
EER from:
EER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UE-E3CM 105/4 / UI-L2CU M 53 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
42HK36VDS8C/38HU36VDT8C
Cassette
|
CIAT | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
42HU36VDS8C/38HU36VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
42HK36VDS8C/38HU36VDS8C
Cassette
|
CIAT | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
42HY36VDS8C/38HU36VDT8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
42HY36VDS8C/38HU36VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
42HK30VDS8C/38HU30VD8SC
Cassette
|
CIAT | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.20 | 4.00 | -10° | 8.80 | 7.50 | |
|
42HY30VDS8C/38HU30VDS8C
Ducted
|
CIAT | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
42HU36VDS8C/38HU36VDS8C
Ceiling suspended
|
CIAT | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.20 | 3.62 | -10° | 10.50 | 8.60 |