Filters · 4 active
Manufacturer:
AIRCLASS
Fujitsu Atlantic
MIDEA
AIRWELL
(12)
ATLANTIC
(3)
AUX
(12)
BOSCH
(13)
BRYANT
(0)
Buderus
(1)
CARRIER
(13)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(93)
EQUATION
(0)
FUJI ELECTRIC
(23)
FUJITSU
(68)
GENERAL
(27)
GREE
(13)
GSS
(0)
HAIER
(43)
HEC
(0)
HEIWA
(0)
HISENSE
(15)
HITACHI
(50)
IVT
(0)
Inventor
(10)
KAYSUN
(13)
LG
(27)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(107)
NORD
(4)
Nobu
(0)
PANASONIC
(26)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(22)
THERMOR
(2)
TOSHIBA
(41)
Viessmann
(8)
Vulcano
(1)
WESTPOINT
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG36KATA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
M4OB-36HFN8-Q/MSAFCU-18HRFNX-QRD0GW+MSAFCU-18HRFNX-QRD0GW
M4OB-36HFN8-Q
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
M4OB-36HFN8-Q(H)/ACE-18HRFN8 IN+ACE-18HRFN8 IN
M4OB-36HFN8-Q
|
MIDEA | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.35 | -10° | 10.30 | 8.40 | |
|
M4OB-36HFN8-Q/MSAGCU-18HRFNX-QRD0GW+MSAGCU-18HRFNX-QRD0GW
M4OB-36HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
M4OB-36HFN8-Q-GR/MSAGCU-18HRFNX-QRD0GW-GR+MSAGCU-18HRFNX-QRD0GW-GR
M4OB-36HFN8-Q
|
MIDEA | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
AOYG30KATA/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
MOD30U-36HFN8-RRD0W(GA)/MCD1-36HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
MOD30U-36HFN8-R(GA)/MCD1-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
MO-36N8-R/MCD-36NX
Cassette R32
|
MIDEA | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
MOD30U-36HFN8-RRD0W(GA)/MCD1-36HRFN8-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
MOD30U-36HFN8-RRD0W(GA)-GR/MCD1-36HRFN8-QRD0W(GA)-GR
Cassette R32
|
MIDEA | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
MOD30U-36HFN8-R(GA)/MCD2-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
MOD30U-36HFN8-RRD0W(GA)/MCD1-36HRFNX-QRD0W(GA)-W
Cassette R32
|
MIDEA | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
MOD30U-36HFN8-R(H)/MCD2-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
AOYG36KATA/ARXG36KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXG36KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KATA/ARXH36KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXH36KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
MOD30U-36HFN8-RRD0W(GA)/MUE-36HRFNX-QRD0W(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(GA)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-RRD0W(GA)/MUE-36HRFNX-QRD0W(GA)-X
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MO-36N8-R/MUE-36NX
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(GA)/MUE2-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MO-36N8-R/MUE-36NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(H)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
AOYG30KATA/AUXG30KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
MOD30U-36HFN8-QRD0W(GA)/MCD1-36HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-Q(GA)/MCD1-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MO-36N8-Q/MCD-36NX
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-QRD0W(GA)/MCD1-36HRFN8-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-Q(GA)/MCD2-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-Q(H)/MCD2-36HRFN8(GA)
Cassette R32
|
MIDEA | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
MOD30U-36HFN8-RRD0W(GA)/MTI-36HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-R(GA)/MTI-36HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-RRD0W(GA)/MTI-36HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MO-36N8-R/MTI-36HNX
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-RRD0W(GA)/MTJ-36HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-R(GA)/MTJ-36HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
MO-36N8-R/MTJ-36NX
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-RRD0W(GA)-GR/MTI-36HWFNX-QRD0W(GA)-GR
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-R(H)/MTJ-36HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
MOD30U-30HFN8-QRD0W(GA)/MCD1-30HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
MOD30U-30HFN8-Q(GA)/MCD1-30HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
MO-30N8-Q/MCD-30NX
Cassette R32
|
MIDEA | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 |