Filters · 7 active
Manufacturer:
AIRCLASS
CIAT
COLIBRI
HAIER
LG
Vulcano
AIRWELL
(12)
ATLANTIC
(3)
AUX
(12)
BOSCH
(13)
BRYANT
(0)
Buderus
(1)
CARRIER
(13)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(93)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(23)
FUJITSU
(68)
Fujitsu Atlantic
(29)
GENERAL
(27)
GREE
(13)
GSS
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(18)
HITACHI
(50)
IVT
(0)
Inventor
(10)
KAYSUN
(13)
MIDEA
(66)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(107)
NORD
(4)
Nobu
(0)
PANASONIC
(26)
PITSOS
(0)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(22)
THERMOR
(2)
TOSHIBA
(41)
Viessmann
(8)
WESTPOINT
(0)
XTRON
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
5U105S2SS5FA/AS71S2SF1FA-MW3+AS50S2SF1FA-MW3
Flexis-Multisplit
|
HAIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS50S2SJ1FA-3+AS50S2SJ1FA-3
Jade-Multisplit
|
HAIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS50XCAHRA+AS50XCAHRA
Expert-Multisplit
|
HAIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U105S2SS5FA/AS71S2SF2FA-3+AS50S2SF2FA-3
Flair plus-Multisplit
|
HAIER | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.30 | -10° | 8.50 | 7.50 | |
|
5U125S2SN1FA/AS68PDAHRA+AS68PDAHRA
Pearl-Multisplit
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 10.50 | 8.70 | |
|
5U125S2SN1FA/AS71SEPHRA-MW+AS71SEPHRA-MW
Serene-Multisplit
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 10.50 | 8.70 | |
|
5U125S2SN1FA/AS71S2SF2FA-3/AS71S2SF2FA-3
Flair plus-Multisplit
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 11.00 | 8.70 | |
|
5U125S2SN1FA/AS71XCAHRA+AS71XCAHRA
Expert-Multisplit
|
HAIER | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 3.20 | -10° | 11.00 | 8.70 | |
|
ABH105H1ERG/1U105S2SS1FB
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 6.00 | |
|
AB105S2SR1FA(H)/1U105S2SS1FB
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 6.00 | |
|
MU5R40 U42 / MJ18PC NSK / MJ24PC NSK
MU
|
LG | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.05 | -15° | 10.00 | 8.00 | |
|
AC105S2SH1FA(H)/1U105S2SS1FB
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.50 | -10° | 9.50 | 6.00 | |
|
UUD1 U30 / US36F NR0
UU
|
LG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.85 | 3.90 | -10° | 9.50 | 8.70 | |
|
UUD3 U30 / US36F NR0
UU
|
LG | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.85 | 3.90 | -10° | 9.50 | 8.70 | |
|
ABH105H1ERG/1U105S2SS2FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 7.00 | |
|
AB105S2SR1FA(H)/1U105S2SS2FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.50 | -10° | 9.20 | 7.00 | |
|
UE-E3CM 105/4 / UI-L2CU M 53 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
AC105S2SH1FA/1U105S2SS2FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
AC105S2SH2FA(H)/1U105S2SS2FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.80 | 3.32 | -10° | 9.50 | 7.00 | |
|
A5UW40GFA1 / ZMNW18GSKC0 / ZMNW24GSKC0
MU
|
LG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.81 | 3.10 | -15° | 10.00 | 8.00 | |
|
AS105S2SF2FA-2/1U105S2SS1FA
Flair Plus
|
HAIER | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 9.00 | 7.20 | |
|
AS105S2SF2FA-2/1U105S2SQ1FA
Flair
|
HAIER | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.20 | -10° | 9.00 | 7.20 | |
|
AP105S2SK1FA(H)/1U105S2SS1FB
Cabinet-Monosplit
|
HAIER | Cabinet | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.60 | -10° | 9.20 | 7.50 | |
|
AP105S2SK1FA(H)/1U105S2SS2FA
Cabinet-Monosplit
|
HAIER | Cabinet | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.50 | -10° | 9.20 | 7.50 | |
|
AB105S2SR1FA(H)/1U105S2SQ1FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 9.50 | 7.20 | |
|
AC105S2SH2FA(H)/1U105S2SS1FB
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.91 | 3.50 | -10° | 9.50 | 6.00 | |
|
UUD1 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N20
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD1 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UM36F N21
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.90 | -10° | 9.50 | 9.50 | |
|
UUC1 U40 / UM36F N20
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
UUC1 U40 / UM36F N21
U4
|
LG | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.57 | -10° | 9.50 | 5.50 | |
|
4U85S2LR1FA/AS35PBPHRA-PRE+AS50PDPHRA-PRE
Pearl Premium-Multisplit
|
HAIER | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 8.50 | 6.00 | |
|
ABH105H1ERG(H)/1U105S2SS1FB
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 6.00 | |
|
ABH105H1ERG(H)/1U105S2SS2FA
Round Flow Cassette-Monosplit
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
AC105S2SH1FA/1U105S2SS1FB
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 4.00 | 3.50 | -10° | 9.50 | 6.00 | |
|
42HK36VDS8C/38HU36VDT8C
Cassette
|
CIAT | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
UUC1 U40 / US36F NR0
U4
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 9.50 | 5.80 | |
|
AC105S2SH1FA(H)/1U105S2SS2FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 4.00 | 3.32 | -10° | 9.50 | 7.00 | |
|
AD90S2SM3FA(H)/ 1U90S2SS2FA
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.65 | -10° | 8.50 | 7.00 | |
|
AD90S2SM9FA(H)/1U90S2SS2FA
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.00 | 7.00 | |
|
4U105S2LS1FA/AS50PDPHRA-PRE+AS50PDPHRA-PRE
Pearl Premium-Multisplit
|
HAIER | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.70 | -10° | 10.50 | 7.50 | |
|
42HU36VDS8C/38HU36VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.61 | -10° | 10.80 | 8.70 | |
|
42HK36VDS8C/38HU36VDS8C
Cassette
|
CIAT | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
Z5UW36GFA3 / ZMNW12GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.11 | 4.01 | 3.10 | -10° | 9.00 | 5.90 | |
|
AD105S2SM9FA(H)/1U105S2SS2FA
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.50 | 7.20 | |
|
42HY36VDS8C/38HU36VDT8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
AD105S2SM9FA(H)/1U105S2SQ1FA
Duct Medium Pressure- Monosplit
|
HAIER | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -10° | 9.50 | 7.20 | |
|
MU5R36 U36A0 / MJ18PC NSK0 / MJ18PC NSK0
MU
|
LG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.15 | 3.25 | -10° | 9.20 | 6.80 | |
|
AC105S2SH2FA(H)/1U105S2SQ1FA
Ceiling floor- Monosplit
|
HAIER | Ceiling suspended | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.05 | 3.71 | -10° | 9.50 | 7.20 |