Filters · 9 active
Manufacturer:
BOSCH
COLIBRI
Candy
Fujitsu Atlantic
Inventor
Rotenso
SAMSUNG
Vulcano
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(3)
AUX
(12)
BRYANT
(0)
Buderus
(1)
CARRIER
(13)
CIAT
(8)
CONFORT AIR
(0)
DAIKIN
(93)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(23)
FUJITSU
(68)
GENERAL
(27)
GREE
(13)
GSS
(0)
HAIER
(43)
HEC
(0)
HEIWA
(0)
HISENSE
(18)
HITACHI
(50)
IVT
(0)
KAYSUN
(13)
LG
(27)
MIDEA
(66)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(107)
NORD
(4)
Nobu
(0)
PANASONIC
(26)
PITSOS
(0)
RIELLO
(8)
THERMOR
(2)
TOSHIBA
(41)
Viessmann
(8)
WESTPOINT
(0)
XTRON
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AJ100TXJ5KH / AJ050TNAPKH / AJ050TNAPKH
FJM
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.51 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
AJ100TXJ5KG / AR60F18C1AW / AR60F18C1AW
FJM
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.58 | 3.83 | 3.63 | -10° | 8.56 | 7.70 | |
|
AOYG36KATA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ABYG36KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
CL5000M 105/4 / CL3000iU W 53 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
UE-E3CM 105/4 / UI-L2CU M 53 + UI-L2CU M 53
Easy Cool M
|
Vulcano | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
U5MRSL32(4)-36/LN2UVI-18WFI+LN2UVI-18WFI
ODU + Wall Mounted
|
Inventor | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 | |
|
AOYG30KATA/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.50 | -15° | 8.50 | 8.00 | |
|
AC100RXADKG/AC100RNTDKG
CAC
|
SAMSUNG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 2.82 | -20° | 9.50 | 5.60 | |
|
AC100RXADNG/AC100RNTDKG
CAC
|
SAMSUNG | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 2.98 | -20° | 9.50 | 5.60 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
AOYG36KATA/ARXG36KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXG36KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KATA/ARXH36KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXH36KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
U5MRSL32(4)-36/AR5VI-18WiFi+AR5VI-18WiFi
ODU + Wall Mounted
|
Inventor | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.20 | -10° | 10.50 | 8.30 | |
|
CL5000L 105 E-3 / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
AOYG30KATA/AUXG30KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AC100RXADKG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.20 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNMDKG
CAC
|
SAMSUNG | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.00 | 3.27 | -20° | 10.00 | 5.20 | |
|
AOYG30KBTB/ABYG30KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.61 | -15° | 8.50 | 8.00 | |
|
AC100RXADKG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | -20° | 10.00 | 5.20 | |
|
AC100RXADNG/AC100RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -20° | 10.00 | 5.20 | |
|
CL5000L 105 E / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
U7RS-36/V7CI-36WiFiR
Cassette R32
|
Inventor | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
CL5001L 105 E-3 / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U7RS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
U7iRS-30/V7CI-30WiFiR
Cassette R32
|
Inventor | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
U7RS-36/V7DI-36WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
AOYG36KBTB/ARXG36KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/ARXG36KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
AOYG30KBTB/ARXG30KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXG30KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
U7RS-36/V7KI-36WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AC100BXAPKG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AC100BXAPNG/AC100BNTPKG
CAC HEE
|
SAMSUNG | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.10 | 3.13 | -25° | 9.50 | 6.50 | |
|
AOYG36KBTB/AUXG36KRLB
AUY**K
|
Fujitsu Atlantic | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOYG36KRTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.30 | 4.40 | -15° | 9.50 | 8.70 | |
|
AOYG36KBTB/ARXH36KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.10 | 4.00 | -15° | 9.50 | 8.70 |