Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(16)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(3)
Fujitsu Atlantic
(1)
GENERAL
(2)
GREE
(1)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(2)
MIDEA
(0)
MITSUBISHI ELECTRIC
(16)
Mitsubishi Heavy Industries
(6)
NORD
(0)
Nobu
(0)
PANASONIC
(4)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(0)
TOSHIBA
(3)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOEH36KMTB/ASEH36KMTB
ASE**K
|
FUJITSU | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOHH36KMTB/ASHH36KMTB
ASY**K
|
GENERAL | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
FUJITSU | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
ROH36KMTB/RSH36KMTB
RS**K
|
FUJI ELECTRIC | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
AOYH36KMTB/ASYH36KMTB
ASY**K
|
Fujitsu Atlantic | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.50 | 3.70 | -15° | 9.40 | 7.10 | |
|
PUZ-SM100VKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA2/PLA-SM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PLA-SM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.61 | -15° | 9.50 | 8.00 | |
|
RZAG100NV1 / FUA100A
RZAG
|
DAIKIN | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.50 | 4.03 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FUA100A
RZAG
|
DAIKIN | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.50 | -10° | 9.50 | 7.80 | ||
|
RZAG100NV1 / FCAG100B
RZAG
|
DAIKIN | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.53 | 3.59 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FCAG100B
RZAG
|
DAIKIN | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.53 | -10° | 9.50 | 7.80 | ||
|
RZAG100NV1 / FHA100A
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.61 | 3.97 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FHA100A
RZAG
|
DAIKIN | Ceiling suspended | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.42 | 4.61 | -10° | 9.50 | 7.80 | ||
|
FDC100VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.53 | 4.29 | -15° | 10.00 | 6.40 | |
|
UUD1 U30 / UT36FH NA0
UU
|
LG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.50 | 4.50 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UT36FH NA0
UU
|
LG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.50 | 4.50 | -10° | 9.50 | 9.50 | |
|
FDC100VNA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.26 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDT100VH
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.78 | 4.52 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC90VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.56 | 4.74 | -15° | 9.00 | 6.00 | |
|
RZAG100NV1 / FCAG50B / FCAG50B
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.64 | 4.64 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FCAG50B / FCAG50B
RZAG
|
DAIKIN | Cassette | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.64 | 4.64 | -10° | 9.50 | 7.80 | |
|
AUW105U4RW8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.90 | -10° | 10.00 | 8.00 | |
|
AUW105U6RW8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.90 | -10° | 10.00 | 8.00 | |
|
PUZ-M100YKA2/PLA-M100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA2/PLA-M100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PLA-M100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PLA-M100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.60 | 3.71 | -15° | 9.50 | 8.00 | |
|
RZAG100NV1 / FHA50A9 / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.75 | 4.54 | 4.54 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FHA50A9 / FHA50A9
RZAG
|
DAIKIN | Ceiling suspended | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.75 | 4.54 | 4.54 | -10° | 9.50 | 7.80 | |
|
FDC100VNA-W/FDT100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.08 | 4.60 | 4.41 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDT100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.08 | 4.60 | 4.41 | -20° | 10.00 | 8.50 | |
|
RZAG100NV1 / FCAHG100H
RZAG
|
DAIKIN | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.75 | 5.01 | -10° | 9.50 | 9.52 | |
|
RZAG100NY1 / FCAHG100H
RZAG
|
DAIKIN | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.70 | 4.75 | 5.01 | -10° | 9.50 | 9.52 | |
|
U-100PZH4E8 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.20 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
U-100PZH4E5 / S-1014PT3E
2023
|
PANASONIC | Ceiling suspended | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.30 | 4.50 | 4.00 | -20° | 9.50 | 7.80 | |
|
RZAG100NV1 / FNA50A9 / FNA50A9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FNA50A9 / FNA50A9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FDXM50F9 / FDXM50F9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
RZAG100NV1 / FDXM50F9 / FDXM50F9
RZAG
|
DAIKIN | Ducted | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.60 | 4.51 | 4.51 | -10° | 9.50 | 7.80 | |
|
AC100BXAPKG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AC100BXAPNG/AC100BN6PKG
CAC HEE
|
SAMSUNG | Cassette | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.60 | 4.07 | -25° | 10.00 | 8.00 | |
|
AOEG36KBTA5/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG/ASEH07KMCG
AOE**K Multi
|
FUJITSU | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
AOHG36KBTA5/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG/ASHH07KMCG
AOH**K Multi
|
GENERAL | Wall mounted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.50 | -15° | 9.50 | 7.00 | |
|
PUZ-ZM100YDA/PLA-ZM50EA2/PLA-ZM50EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PLA-ZM50EA3/PLA-ZM50EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 90 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
GUD85ZD1/A-S/GUD85W1/NhA-S
MONOSPLITS
|
GREE | Ceiling/Floor | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.50 | -10° | 8.50 | 6.00 | ||
|
PUZ-ZM100YDA/PLA-ZM100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.80 | 4.20 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PLA-ZM100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.60 | 4.80 | 4.20 | -20° | 9.50 | 7.80 |