Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(1)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(22)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(3)
Fujitsu Atlantic
(1)
GENERAL
(2)
GREE
(4)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(8)
HITACHI
(8)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(5)
MIDEA
(0)
MITSUBISHI ELECTRIC
(16)
Mitsubishi Heavy Industries
(16)
NORD
(0)
Nobu
(0)
PANASONIC
(6)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(9)
THERMOR
(0)
TOSHIBA
(11)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
Z5UW36GFA3 / ZMNW12GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.11 | 4.01 | 3.10 | -10° | 9.00 | 5.90 | |
|
RZASG100MV1 / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MV1 / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
GWHD(42)NK6QO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
GWHD(42)NK6ZO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
RZAG100NV1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FFA50A9 / FFA50A9
RZAG
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.03 | 4.17 | 4.17 | -10° | 9.50 | 7.80 | |
|
GWHD(36)NK6OO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
GWHD(36)NK6RO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
UUD1 U30 / UT36F NA0
UU
|
LG | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 4.45 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UT36F NA0
UU
|
LG | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 4.45 | -10° | 9.50 | 9.50 | |
|
RAM-Y85N5HAE / RAK-XJ35RHBE / RAK-XJ50RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 3.90 | -10° | 8.50 | 6.80 | |
|
RAM-Y85N5HAE / RAK-XJ35RHBE / RAK-XJ50RHBE
RAM-YNHAE
|
HITACHI | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 3.90 | -10° | 8.50 | 6.80 | |
|
RAV-GM1102AT8W-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.15 | 4.29 | 3.97 | -15° | 9.50 | 8.00 | |
|
AJ100HCJ5KG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG / AJ025HEAPKG
FJM
|
SAMSUNG | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.26 | 4.28 | 3.87 | -10° | 9.80 | 7.91 | |
|
RAS-5M34G3AVG-E1/RAS-B16G3KVSG-E+RAS-B16G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.25 | -20° | 9.20 | 6.23 | |
|
38WH5M100C1A0TEE/40WHHW046D1A0TEE/40WHHW046D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.25 | -20° | 9.20 | 6.23 | |
|
RAS-5M34G3AVG-E1/RAS-B16P2KVSG-E+RAS-B16P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.20 | 4.25 | -20° | 9.20 | 6.23 | |
|
RAM-G85N5HCE / RAK-XJ35RHBE / RAK-XJ50RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.90 | 4.30 | 3.90 | -10° | 8.50 | 6.80 | |
|
PUZ-ZM100YDA/PLA-M100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.30 | 4.17 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100YDA2/PLA-M100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.30 | 4.17 | -20° | 9.50 | 7.80 | |
|
AUW105U6RN8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -10° | 10.00 | 8.00 | |
|
PUZ-ZM100VDA/PLA-M100EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.30 | 4.17 | -20° | 9.50 | 7.80 | |
|
PUZ-ZM100VDA2/PLA-M100EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.30 | 4.17 | -20° | 9.50 | 7.80 | |
|
FDC100VNX-W/FDT50VH/FDT50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.24 | 4.24 | 4.25 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDT50VH/FDT50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.24 | 4.24 | 4.25 | -20° | 10.00 | 11.20 | |
|
RAM-90NYP5E / RAK-35RXE / RAK-50RXE
RAM-NYPE
|
HITACHI | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.31 | 3.90 | -15° | 8.50 | 7.10 | |
|
AC100RXADKG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.61 | -20° | 10.00 | 5.30 | |
|
AC100RXADNG/AC100RN4DKG
CAC
|
SAMSUNG | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.69 | -20° | 10.00 | 5.30 | |
|
RAM-G85N5HAE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RAM-G85N5HBE / RAK-XJ35RHAE / RAK-XJ50RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.95 | 4.30 | 3.90 | -15° | 8.50 | 6.80 | |
|
RZAG100NV1 / FCAG100B
RZAG
|
DAIKIN | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.53 | 3.59 | -10° | 9.50 | 7.80 | |
|
RZAG100NY1 / FCAG100B
RZAG
|
DAIKIN | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.14 | 4.53 | -10° | 9.50 | 7.80 | ||
|
AOYG36KBTA5/ASYG18KMTB/ASYG18KMTB
AOY**K Multi
|
FUJITSU | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOHG36KBTA5/ASHG18KMTB/ASHG18KMTB
AOH**K Multi
|
GENERAL | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
ROG36KBTA5/RSG18KMTB/RSG18KMTB
RO**K Multi
|
FUJI ELECTRIC | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOEG36KBTA5/ASEG18KMTE/ASEG18KMTE
AOE**K Multi
|
FUJITSU | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
AOYG36KBTA5/ASYG18KMTB/ASYG18KMTB
AOY**K Multi
|
Fujitsu Atlantic | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.80 | 4.30 | 4.00 | -15° | 9.50 | 7.00 | |
|
RAV-GP1101AT8-E/RAV-HM1101UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.32 | 4.38 | 4.65 | -20° | 10.00 | 9.50 | |
|
FDC100VNP-W/FDT100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.53 | 4.29 | -15° | 10.00 | 6.40 | |
|
UUD1 U30 / UT36FH NA0
UU
|
LG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.50 | 4.50 | -10° | 9.50 | 9.50 | |
|
UUD3 U30 / UT36FH NA0
UU
|
LG | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.50 | 4.50 | -10° | 9.50 | 9.50 | |
|
RAV-GM1102ATW-E/RAV-HM1101CTP-E
DI
|
TOSHIBA | Ceiling suspended | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.30 | 3.91 | -15° | 9.50 | 8.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.40 | 3.92 | -15° | 9.50 | 8.00 |