Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(5)
ATLANTIC
(0)
AUX
(4)
BOSCH
(6)
BRYANT
(0)
Buderus
(0)
CARRIER
(6)
CIAT
(3)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(39)
EQUATION
(0)
FUJI ELECTRIC
(9)
FUJITSU
(31)
Fujitsu Atlantic
(15)
GENERAL
(15)
GREE
(3)
GSS
(0)
HAIER
(9)
HEC
(0)
HEIWA
(0)
HISENSE
(8)
HITACHI
(18)
IVT
(0)
Inventor
(4)
KAYSUN
(7)
LG
(8)
MIDEA
(25)
MITSUBISHI ELECTRIC
(40)
Mitsubishi Heavy Industries
(44)
NORD
(2)
Nobu
(0)
PANASONIC
(4)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(5)
THERMOR
(1)
TOSHIBA
(15)
Viessmann
(3)
Vulcano
(0)
WESTPOINT
(0)
YORK
(3)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RZASG100MV1 / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | 3.80 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | 3.80 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FBA50A9 / FBA50A9
RZASG
|
DAIKIN | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.38 | 3.80 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV1 / ADEA100A
AZAS
|
DAIKIN | Ducted | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.13 | 3.81 | 4.63 | -10° | 9.50 | 6.00 | |
|
AZAS100MV1 / FBA100A
AZAS
|
DAIKIN | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 4.77 | -10° | 9.50 | 6.00 | |
|
AZAS100MY1 / FBA100A
AZAS
|
DAIKIN | Ducted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.25 | 3.81 | 4.77 | -10° | 9.50 | 6.00 | |
|
AZAS100MY / ADEA100A
AZAS
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.55 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / ADEA100A
AZAS
|
DAIKIN | Ducted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.55 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MV / FBA100A
AZAS
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
AZAS100MY / FBA100A
AZAS
|
DAIKIN | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.67 | 3.81 | -10° | 9.50 | 6.00 | ||
|
RAV-GV1101ATP-E/RAV-HM1101BTP-E
DIC
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.33 | -15° | 9.50 | 7.60 | |
|
RAV-GV1401ATP-E/RAV-HM1401BTP-E
DIC
|
TOSHIBA | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.05 | -15° | 11.50 | 7.80 | |
|
RAV-GV1101AT8P-E/RAV-HM1101BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.80 | 3.40 | -15° | 9.50 | 7.60 | |
|
RZASG100MV1 / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | 4.77 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | 4.77 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FBA100A
RZASG
|
DAIKIN | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.85 | -10° | 9.50 | 6.00 | ||
|
FDC100VSX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.11 | 3.87 | 3.71 | -20° | 10.00 | 8.20 | |
|
FDC100VSX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.17 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
RAV-GM1101ATP-E/RAV-HM1101FT-E
DI
|
TOSHIBA | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.16 | 3.92 | 3.51 | -15° | 9.50 | 7.60 | |
|
RAV-GM1101AT8P-E/RAV-HM1101FT-E
DI 3ph
|
TOSHIBA | Floor standing | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.16 | 3.92 | 3.51 | -15° | 9.50 | 7.60 | |
|
FDC100VNX/FDF100VD2
VNX/VSX (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.80 | 3.68 | -20° | 10.00 | 13.00 | |
|
FDC100VNX/FDUM50VH/FDUM50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.88 | 3.71 | -20° | 10.00 | 8.20 | |
|
RZASG100MV1 / FVA100A
RZASG
|
DAIKIN | Floor standing | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.83 | 4.45 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FVA100A
RZASG
|
DAIKIN | Floor standing | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.83 | 4.45 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FVA100A
RZASG
|
DAIKIN | Floor standing | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.83 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FVA100A
RZASG
|
DAIKIN | Floor standing | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.72 | 3.83 | -10° | 9.50 | 6.00 | ||
|
NAGANO GAINABLE MP IG95MP-NG / E1U90LV2-NG
NAGANO GAINABLE MOYENNE PRESSION
|
THERMOR | Ducted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.49 | -10° | 9.50 | 7.20 | |
|
PUZ-SM100YKA2/PEAD-SM100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA2/PEAD-SM100JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA2/PEAD-SM100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA2/PEAD-SM100JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PEAD-SM100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100VKA3/PEAD-SM100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PEAD-SM100JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
PUZ-SM100YKA3/PEAD-SM100JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.90 | 3.71 | -15° | 9.50 | 8.00 | |
|
AOYG36KATA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KATA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOHG36KATA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RDG36KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/ARXG36KMLA
ARXG**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/ARXG36KMLA
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.56 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/ARXH36KMTAP
ARXH**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/ARXH36KMTAP
ARXH**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOHG36KATA/ARXH36KMTAP
ARX**K
|
GENERAL | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KATA/ARXH36KMTAP
ARX**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/ARXH36KMTAP
ARXG**K
|
FUJITSU | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.75 | -15° | 9.50 | 8.70 |