Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(3)
AUX
(12)
BOSCH
(13)
BRYANT
(0)
Buderus
(1)
CARRIER
(13)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(93)
EQUATION
(0)
FUJI ELECTRIC
(23)
FUJITSU
(68)
Fujitsu Atlantic
(29)
GENERAL
(27)
GREE
(13)
GSS
(0)
HAIER
(43)
HEC
(0)
HEIWA
(0)
HISENSE
(15)
HITACHI
(50)
IVT
(0)
Inventor
(10)
KAYSUN
(13)
LG
(27)
MIDEA
(66)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(107)
NORD
(4)
Nobu
(0)
PANASONIC
(26)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(22)
THERMOR
(2)
TOSHIBA
(41)
Viessmann
(8)
Vulcano
(1)
WESTPOINT
(0)
YORK
(8)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
KUE-105 DTR13/KPC-105 DR14
ZEN Ceiling&Floor
|
KAYSUN | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(GA)/MUE2-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MO-36N8-R/MUE-36NX-CC
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
MOD30U-36HFN8-R(H)/MUE-36HRFNX(GA)
Ceiling&Floor R32
|
MIDEA | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
AOYG30KATA/AUXG30KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
ROG30KATA/RCG30KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/AUXG30KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/AUXG30KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/AUXG30KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.79 | -15° | 8.50 | 8.00 | |
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ROG36KATA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG36KATA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ROG36KQTA/RCG36KRLB
RCG**K
|
FUJI ELECTRIC | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOHG36KQTA/AUXG36KRLB
AUXG**K
|
GENERAL | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOEG36KATA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOEG36KQTA/AUXG36KRLB
AUXG**K
|
FUJITSU | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KATA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
AOYG36KQTA/AUXG36KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 4.19 | -15° | 9.50 | 8.70 | |
|
ABH105H1ERG(H)/1U105S2SS1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 6.00 | |
|
FDC100VNP-W/FDF100VH
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.43 | 3.94 | 3.69 | -15° | 10.00 | 6.40 | |
|
FDC100VNP-W/FDF100VH1
VNP-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.43 | 3.94 | 3.69 | -15° | 10.00 | 6.40 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
ROG30KATA/RDG30KMLA
RDG**K
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/ARXG30KMLA
ARXG**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOEG30KATA/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KATA/ARXH30KMTAP
ARX**K
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXG30KMLA
ARXG**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.61 | -15° | 8.50 | 8.00 | |
|
AOYG30KATA/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.80 | -15° | 8.50 | 8.00 | |
|
AL-H36/4DR3C3(U) / AUCA-H36/4DR3HB2
Q-Cassette
|
AUX | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.08 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDCA105Q-B
Q-Cassette
|
AUX | Cassette | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.08 | -10° | 10.55 | 8.40 | |
|
ABH105H1ERG(H)/1U105S2SS2FA
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.50 | -10° | 9.20 | 7.00 | |
|
FDC100VNA/FDUM50VH/FDUM50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.94 | 3.49 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDUM50VH/FDUM50VH
VNA/VSA (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.94 | 3.49 | -20° | 10.00 | 8.50 | |
|
AC105S2SH1FA/1U105S2SS1FB
R32 Super Match Plus-Convertible
|
HAIER | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 4.00 | 3.50 | -10° | 9.50 | 6.00 | |
|
42QTD036D8S*/38QUS036D8T*
Cassette
|
CARRIER | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
42HK36VDS8C/38HU36VDT8C
Cassette
|
CIAT | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
KC210HIDS8/AIC210HIDT8
Cassette
|
RIELLO | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100TFP105
Cassette
|
Viessmann | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.61 | -10° | 10.50 | 8.00 | |
|
UUC1 U40 / US36F NR0
U4
|
LG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 9.50 | 5.80 | |
|
U-100PZ3E5/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E8/S-5010PK4E/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E5/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZ3E8/S-5010PK4E
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.81 | -15° | 9.00 | 8.80 | |
|
U-100PZH4E8 / S-6010PK3E
2023
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.88 | -20° | 9.50 | 8.00 | |
|
AUW105U4RK7/AUV105UR4RC8
Super Inverter R32
|
HISENSE | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -10° | 9.50 | 8.00 | |
|
RAV-GM1102AT8W-E/RAV-HM1101BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.92 | 3.90 | -15° | 9.50 | 8.40 | |
|
U-100PZ3E5 / S-6010PK3E
2021
|