Filters · 1 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(3)
AUX
(12)
BOSCH
(13)
BRYANT
(0)
Buderus
(1)
CARRIER
(13)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(93)
EQUATION
(0)
FUJI ELECTRIC
(23)
FUJITSU
(68)
Fujitsu Atlantic
(29)
GENERAL
(27)
GREE
(13)
GSS
(0)
HAIER
(43)
HEC
(0)
HEIWA
(0)
HISENSE
(15)
HITACHI
(50)
IVT
(0)
Inventor
(10)
KAYSUN
(13)
LG
(27)
MIDEA
(66)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(107)
NORD
(4)
Nobu
(0)
PANASONIC
(26)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(22)
THERMOR
(2)
TOSHIBA
(41)
Viessmann
(8)
Vulcano
(1)
WESTPOINT
(0)
YORK
(8)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
KC210HIDS8/AIC210HIDS8
Cassette
|
RIELLO | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
Vitoclima100-SPROIC8AA100MFP105/Vitoclima100-SPROOFAA100MFP105
Cassette
|
Viessmann | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 3.55 | -10° | 10.50 | 8.20 | |
|
RAS-5HVNC2E / RPI-5.0FSR1E
UTOPIA PRIME
|
HITACHI | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 3.93 | 3.42 | -20° | 11.90 | 11.93 | |
|
RAS-4HRC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.70 | 4.12 | 3.47 | -20° | 10.00 | 8.70 | |
|
FDC100VNX/FDT50VH/FDT50VH
VNX/VSX (AC1 multi)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.92 | 4.16 | 3.20 | -20° | 10.00 | 11.20 | |
|
CU-5Z90CBE/CS-Z71CKEW/CS-Z71CKEW
2025
|
PANASONIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 4.43 | -15° | 9.00 | 8.50 | |
|
RZASG100MY1 / FCAG100B
RZASG
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.17 | 3.71 | -10° | 9.50 | 6.00 | |
|
RZASG100MV1 / FCAG100B
RZASG
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.17 | 3.71 | -10° | 9.50 | 6.00 | |
|
RZASG100MY / FCAG100B
RZASG
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.17 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FCAG100B
RZASG
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.55 | 4.17 | -10° | 9.50 | 6.00 | ||
|
AL-H36/4DR3C3(U) / AUCF-H36/4DR3HC2
F-Ceiling suspended
|
AUX | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDCF105F-B
F-Ceiling suspended
|
AUX | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RAV-GV1101AT8P-E/RAV-HM1101KRTP-E
DIC 3ph
|
TOSHIBA | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 3.13 | -15° | 9.50 | 7.60 | |
|
AD105S2SM9FA(H)/1U105S2SS2FA
R32 Super Match Plus - Duct
|
HAIER | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 9.50 | 7.20 | |
|
RPIH-3.5UFE1NH/RAS-3.5UFESNH1
Primairy R32 series
|
HITACHI | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.75 | -15° | 8.50 | 6.50 | |
|
Z5UW36GFA3 / ZMNW12GSJL2 / ZMNW24GSKL2
MU
|
LG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.11 | 4.01 | 3.10 | -10° | 9.00 | 5.90 | |
|
RAS-5HVNC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.86 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
RAV-GM1102AT8W-E/RAV-HM1101FT-E
DI 3ph
|
TOSHIBA | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.92 | 3.64 | -15° | 9.50 | 8.30 | |
|
AOYG36LATT/ARYG36LMLA
ARY**L
|
FUJITSU | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.90 | -15° | 10.00 | 10.00 | |
|
RAS-5HRC2E / RPC-5.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.89 | 4.09 | 3.21 | -20° | 11.90 | 11.93 | |
|
SCM100ZS-W/SRK50ZSX-W/SRK50ZSX-W
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 4.00 | -10° | 10.00 | 6.80 | |
|
RAS-4HVNC2E / RPC-4.0FSR
UTOPIA PRIME
|
HITACHI | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.72 | 4.18 | 3.53 | -20° | 10.00 | 8.70 | |
|
FDC100VNX-W/FDF100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.81 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDF100VH
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.80 | -20° | 10.00 | 11.20 | |
|
FDC100VNX-W/FDF100VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.81 | -20° | 10.00 | 11.20 | |
|
FDC100VSX-W/FDF100VH1
VNX-W/VSX-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.84 | 3.80 | -20° | 10.00 | 11.20 | |
|
PUZ-M100VKA2/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA2/PKA-M50LA2/PKA-M50LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PKA-M50LA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PKA-M50LA3/PKA-M50LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100VKA3/PKA-M50LAL3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
PUZ-M100YKA3/PKA-M50LAL3/PKA-M50LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.10 | 3.41 | -15° | 9.50 | 8.00 | |
|
AL-H36/4DR3C3(U) / AUMD-H36/4DR3HC2
M-Ducted
|
AUX | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RXYL105M-T1B/FDMD105M-B
M-Ducted
|
AUX | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.01 | -10° | 10.55 | 8.40 | |
|
RAV-GM1101ATP-E/RAV-HM1101UTP-E
DI
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
RAV-GM1101AT8P-E/RAV-HM1101UTP-E
DI 3ph
|
TOSHIBA | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 4.28 | 3.82 | -15° | 9.50 | 8.00 | |
|
U-100PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 3.90 | 4.09 | -15° | 9.50 | 7.80 | |
|
FDC100VNX-W/FDUM50VH/FDUM50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.88 | 3.79 | -20° | 10.00 | 10.00 | |
|
FDC100VSX-W/FDUM50VH/FDUM50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.36 | 3.88 | 3.79 | -20° | 10.00 | 10.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101FT-E
DI
|
TOSHIBA | Floor standing | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.22 | 3.92 | 3.61 | -15° | 9.50 | 8.30 | |
|
MOD30U-36HFN8-RRD0W(GA)/MTI-36HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-R(GA)/MTI-36HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
42QSS036D8S*/38QUS036D8T*
Ducted
|
CARRIER | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
42HY36VDS8C/38HU36VDT8C
Ducted
|
CIAT | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
DC210HIDS8/AIC210HIDT8
Ducted
|
RIELLO | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.67 | -10° | 10.60 | 8.80 | |
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-RRD0W(GA)/MTI-36HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MO-36N8-R/MTI-36HNX
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
KUE-105 DTR13/KPD-105 DR14
ZEN Duct
|
KAYSUN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
MOD30U-36HFN8-RRD0W(GA)/MTJ-36HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 |