Filters · 3 active
Manufacturer:
BOSCH
HISENSE
AIRCLASS
(0)
AIRWELL
(12)
ATLANTIC
(3)
AUX
(12)
BRYANT
(0)
Buderus
(1)
CARRIER
(13)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(93)
EQUATION
(0)
FUJI ELECTRIC
(23)
FUJITSU
(68)
Fujitsu Atlantic
(29)
GENERAL
(27)
GREE
(13)
GSS
(0)
HAIER
(43)
HEC
(0)
HEIWA
(0)
HITACHI
(50)
IVT
(0)
Inventor
(10)
KAYSUN
(13)
LG
(27)
MIDEA
(66)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(107)
NORD
(4)
Nobu
(0)
PANASONIC
(26)
RIELLO
(8)
Rotenso
(0)
SAMSUNG
(22)
THERMOR
(2)
TOSHIBA
(41)
Viessmann
(8)
Vulcano
(1)
WESTPOINT
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AUW105U4RW8/AUD105UX4REH8
Turbo Inverter R32
|
HISENSE | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 10.00 | 8.00 | |
|
AUW105U6RW8/AUD105UX4REH8
Turbo Inverter R32
|
HISENSE | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 4.00 | -10° | 10.00 | 8.00 | |
|
AUW105U4RW8/AUD105UX4RQM8
Turbo Inverter R32
|
HISENSE | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 4.10 | -10° | 10.00 | 8.00 | |
|
AUW105U6RW8/AUD105UX4RQM8
Turbo Inverter R32
|
HISENSE | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.40 | 4.10 | -10° | 10.00 | 8.00 | |
|
AUW90U4RK8/AUD90UX4RFM8
Turbo Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.80 | 4.40 | 3.73 | -10° | 8.80 | 5.50 | |
|
AUW105U6RN8/AUD105UX4REH8
Turbo Inverter R32
|
HISENSE | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.40 | 4.00 | -10° | 10.00 | 8.00 | |
|
AUW105U4RW8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.90 | -10° | 10.00 | 8.00 | |
|
AUW105U6RW8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.50 | 4.60 | 3.90 | -10° | 10.00 | 8.00 | |
|
AUW105U4RW8/AUV105UR4RC8
Turbo Inverter R32
|
HISENSE | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.73 | -10° | 9.50 | 8.00 | |
|
AUW105U6RW8/AUV105UR4RC8
Turbo Inverter R32
|
HISENSE | Ceiling suspended | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.30 | 3.73 | -10° | 9.50 | 8.00 | |
|
CL5001L 88 E / CL5001iL D 88 E
Climate 5001 L
|
BOSCH | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.20 | 3.90 | -10° | 8.80 | 8.00 | |
|
CL5000L 105 E / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.40 | 4.10 | 3.60 | -10° | 10.50 | 8.60 | |
|
AUW105U6RN8/AUC105UR4RKC8
Turbo Inverter R32
|
HISENSE | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.00 | 4.40 | 3.85 | -10° | 10.00 | 8.00 | |
|
CL5001L 105 E / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.30 | 4.10 | 3.61 | -10° | 10.50 | 8.40 | |
|
AUW105U4RK7/AUF105UR4RMPA8
Super Inverter R32
|
HISENSE | Floor standing | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
CL5000L 105 E / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.71 | -10° | 10.50 | 8.40 | |
|
AUW105U4RK7/AUD105UX4RQM8
Super Inverter R32
|
HISENSE | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
CL5001L 88 E / CL5000iL 4C 88 E
Climate 5001 L
|
BOSCH | Cassette | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 3.83 | -10° | 8.80 | 7.70 | |
|
CL5000L 88 E / CL5000iL 4C 88 E
Climate 5000i L
|
BOSCH | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.20 | 4.00 | -10° | 8.80 | 7.40 | |
|
CL5000L 105 E-3 / CL5000iL D 105 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 10.60 | 8.80 | |
|
CL5001L 105 E-3 / CL5001iL D 105 E
Climate 5001 L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 10.60 | 8.80 | |
|
CL5000L 105 E / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.00 | 3.68 | -10° | 10.50 | 8.50 | |
|
AUW105U4RK7/AUV105UR4RC8
Super Inverter R32
|
HISENSE | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.40 | -10° | 9.50 | 8.00 | |
|
CL5000L 105 E-3 / CL5000iL CF 105 E
Climate 5000i L
|
BOSCH | Ceiling/Floor | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.50 | -10° | 10.50 | 8.60 | |
|
AUW105U4RK7/AUC105UR4RKC8
Super Inverter R32
|
HISENSE | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 8.00 | |
|
CL5000L 105 E-3 / CL5000iL 4C 105 E
Climate 5000i L
|
BOSCH | Cassette | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.90 | 3.68 | -10° | 10.50 | 8.00 | |
|
CL5000M 105/4 / CL3000iU W 53 E + CL3000iU W 53 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.10 | -10° | 10.50 | 8.10 |