Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(8)
ATLANTIC
(3)
AUX
(8)
BOSCH
(8)
BRYANT
(0)
Buderus
(1)
CARRIER
(7)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(57)
EQUATION
(0)
FUJI ELECTRIC
(14)
FUJITSU
(41)
Fujitsu Atlantic
(18)
GENERAL
(15)
GREE
(4)
GSS
(0)
HAIER
(29)
HEC
(0)
HEIWA
(0)
HISENSE
(4)
HITACHI
(12)
IVT
(0)
Inventor
(4)
KAYSUN
(8)
LG
(10)
MIDEA
(42)
MITSUBISHI ELECTRIC
(22)
Mitsubishi Heavy Industries
(29)
NORD
(0)
Nobu
(0)
PANASONIC
(12)
RIELLO
(6)
Rotenso
(0)
SAMSUNG
(8)
THERMOR
(2)
TOSHIBA
(12)
Viessmann
(4)
Vulcano
(1)
WESTPOINT
(0)
YORK
(6)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC100VNA-W/FDF100VH1
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.76 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH1
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.76 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VNA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA-W/FDF100VH
VNA-W/VSA-W (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.72 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
AUW105U4RK7/AUF105UR4RMPA8
Super Inverter R32
|
HISENSE | Floor standing | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.00 | 3.72 | -10° | 10.00 | 7.40 | |
|
FDC100VNA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
FDC100VSA/FDF100VD2
VNA/VSA (AC1 single)
|
Mitsubishi Heavy Industries | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.70 | 4.00 | 3.81 | -20° | 10.00 | 8.50 | |
|
42QSS030D8S*/38QUS030D8S*
Ducted
|
CARRIER | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
42HY30VDS8C/38HU30VDS8C
Ducted
|
CIAT | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
DC280HIDS8/AIC280HIDS8
Ducted
|
RIELLO | Ducted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.00 | 4.04 | -10° | 8.75 | 8.00 | |
|
RAV-GM1102ATW-E/RAV-HM1101BTP-E
DI
|
TOSHIBA | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.85 | -15° | 9.50 | 8.40 | |
|
AOYG30KBTB/ARXG30KHTAP
ARY**K
|
FUJITSU | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXG30KMLA
ARY**K
|
FUJITSU | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ARXG30KHTAP
ARH**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ARXG30KMLA
ARH**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
ROG30KBTB/RDG30KHTAP
RD**K
|
FUJI ELECTRIC | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
ROG30KBTB/RDG30KMLA
RD**K
|
FUJI ELECTRIC | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOEG30KBTB/ARXG30KHTAP
ARXG**K
|
FUJITSU | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOEG30KBTB/ARXG30KMLA
ARXG**K
|
FUJITSU | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOEG30KBTB/ARXH30KMTAP
ARXH**K
|
FUJITSU | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AOHG30KBTB/ARXH30KMTAP
ARX**K
|
GENERAL | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
FUJITSU | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXG30KHTAP
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXG30KMLA
ARY**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 3.80 | -15° | 8.50 | 8.00 | |
|
AOYG30KBTB/ARXH30KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.23 | 4.00 | 4.00 | -15° | 8.50 | 8.00 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-Q(GA)/MTI-30HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
CL5000L 88 E / CL5000iL D 88 E
Climate 5000i L
|
BOSCH | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MOD30U-30HFN8-QRD0W(GA)/MTI-30HWFNX-QRD0W(GA)-X
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
MO-30N8-Q/MTI-30HNX
Duct R32
|
MIDEA | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
KUE-90 DVR13/KPD-90 DR14
ZEN Duct
|
KAYSUN | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
YUKF30BYEEBMO-1/YEKF30BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 4.25 | -10° | 8.80 | 8.00 | |
|
FDC100VNX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
FDC100VSX-W/FDE50VH/FDE50VH
VNX-W/VSX-W (AC1 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.76 | 4.00 | 3.89 | -20° | 10.00 | 9.80 | |
|
GWHD(36)NK6OO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
GWHD(36)NK6RO GWH18AGD-K6DNA1E/I*2 *2
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.20 | -10° | 10.60 | 10.50 | |
|
42QSS036D8S*/38QUS036D8S*
Ducted
|
CARRIER | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
42HY36VDS8C/38HU36VDS8C
Ducted
|
CIAT | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
DC210HIDS8/AIC210HIDS8
Ducted
|
RIELLO | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.69 | -10° | 10.50 | 8.40 | |
|
GWHD(42)NK6QO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
GWHD(42)NK6ZO GWH18AGD-K6DNA1E/I+GWH24AGE-K6DNA1A/I
MULTISPLITS FREE MATCH
|
GREE | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.00 | 3.55 | -10° | 11.80 | 10.80 | |
|
AL-H30/4DR3HB3(U) / AUMD-H30/4DR3HC2
M-Ducted
|
AUX | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 8.79 | 6.80 | |
|
RXYL90M-T1B/FDMD90M-B
M-Ducted
|
AUX | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.00 | 3.75 | -10° | 8.79 | 6.80 | |
|
RZASG100MV1 / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MV1 / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MY1 / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | 3.93 | -10° | 9.50 | 6.00 | |
|
RZASG100MV / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MV / FDXM50F9 / FDXM50F9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 | ||
|
RZASG100MY / FNA50A9 / FNA50A9
RZASG
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.68 | 3.93 | -10° | 9.50 | 6.00 |