Filters · 4 active
Manufacturer:
AIRCLASS
Candy
TOSHIBA
AIRWELL
(0)
ATLANTIC
(2)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
DAIKIN
(285)
EQUATION
(0)
FUJI ELECTRIC
(29)
FUJITSU
(79)
Fujitsu Atlantic
(41)
GENERAL
(40)
GREE
(0)
GSS
(0)
HAIER
(130)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(22)
IVT
(0)
Inventor
(25)
KAYSUN
(23)
LG
(59)
MIDEA
(114)
MITSUBISHI ELECTRIC
(132)
Mitsubishi Heavy Industries
(168)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
Rotenso
(8)
SAMSUNG
(24)
THERMOR
(0)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GV1401AT8P-E/RAV-HM1401UTP-E
DIC 3ph
|
TOSHIBA | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.90 | 3.00 | -15° | 12.10 | 7.80 | |
|
RAV-GM1602AT8W-E/RAV-HM1601FT-E
DI 3ph
|
TOSHIBA | Floor standing | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.82 | 2.83 | -15° | 14.00 | 8.30 | |
|
RAV-GV1401AT8P-E+RAV-HM1401BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.00 | -15° | 12.10 | 7.80 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401FT-E
DI 3ph
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401FT-E
DI
|
TOSHIBA | Floor standing | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 4.86 | 3.90 | 3.24 | -15° | 12.10 | 7.60 | |
|
RAV-GM1602ATW-E/RAV-HM1601FT-E
DI
|
TOSHIBA | Floor standing | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 2.83 | -15° | 14.00 | 8.30 | |
|
RAV-GM1402AT8W-E/RAV-HM1401FT-E
DI 3ph
|
TOSHIBA | Floor standing | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.35 | 3.90 | 3.34 | -15° | 12.10 | 8.30 | |
|
RAV-GM1601ATP-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.30 | 3.90 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GM1402AT8W-E/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.87 | 3.84 | 3.71 | -15° | 12.10 | 8.40 | |
|
RAV-GV1601AT8P-E1/RAV-HM1601UTP-E
DIC 3ph
|
TOSHIBA | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.17 | 3.46 | -15° | 13.00 | 8.00 | |
|
RAV-GM1402ATW-E/RAV-HM1401FT-E
DI
|
TOSHIBA | Floor standing | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.53 | 3.90 | 3.29 | -15° | 12.10 | 8.30 | |
|
RAV-GV1601ATP-E1/RAV-HM1601UTP-E
DIC 1ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.46 | -15° | 13.00 | 8.00 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401ATP-E1/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 4.19 | 3.74 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 4.19 | 3.74 | -15° | 12.10 | 7.60 | |
|
RAV-GM1602AT8W-E/RAV-HM1601BTP-E
DI 3ph
|
TOSHIBA | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.96 | 3.43 | -15° | 14.00 | 8.40 | |
|
RAV-GP1601AT8-E/RAV-HM1601BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.81 | 3.96 | 3.50 | -20° | 14.00 | 12.00 | |
|
RAV-GM1402ATW-E/RAV-HM1401BTP-E
DI
|
TOSHIBA | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.15 | 3.92 | 3.66 | -15° | 12.10 | 8.40 | |
|
RAV-GV1601ATP-E1/RAV-HM1601BTP-E
DIC 1ph
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 4.90 | 4.15 | 3.38 | -15° | 13.00 | 8.00 | |
|
RAV-GV1601AT8P-E1/RAV-HM1601BTP-E
DIC 3ph
|
TOSHIBA | Ducted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 4.90 | 4.15 | 3.38 | -15° | 13.00 | 8.00 | |
|
RAV-GM1601ATP-E/RAV-HM1601CTP-E
DI
|
TOSHIBA | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.47 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.47 | -15° | 14.00 | 8.00 | |
|
RAV-GP1401AT8-E1/RAV-HM1401BTP-E
SDI 3ph
|
TOSHIBA | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.02 | 3.98 | 3.83 | -20° | 12.50 | 11.80 | |
|
RAV-GM1402AT8W-E/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.20 | 3.79 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401BTP-E
DI 3ph
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.36 | 4.19 | 3.61 | -15° | 12.10 | 7.60 | |
|
RAV-GM1401ATP-E1/RAV-HM1401BTP-E
DI
|
TOSHIBA | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.36 | 4.19 | 3.61 | -15° | 12.10 | 7.60 | |
|
RAV-GM1602ATW-E/RAV-HM1601BTP-E
DI
|
TOSHIBA | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.05 | 3.38 | -15° | 14.00 | 8.40 | |
|
RAV-GM1602AT8W-E/RAV-HM1601CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.22 | 3.41 | -15° | 14.00 | 8.00 | |
|
RAV-GP1601AT8-E/RAV-HM1601FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.98 | 3.31 | -20° | 14.00 | 12.00 | |
|
RAV-GM1601ATP-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
RAV-GM1601AT8P-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.35 | 3.61 | -15° | 14.00 | 8.00 | |
|
RAV-GM1402ATW-E/RAV-HM1401CTP-E
DI
|
TOSHIBA | Ceiling suspended | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.16 | 4.28 | 3.74 | -15° | 12.10 | 8.00 | |
|
RAV-GM1402AT8W-E/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.91 | 4.30 | 3.83 | -15° | 12.10 | 8.00 | |
|
RAV-GM1602AT8W-E/RAV-HM1601UTP-E
DI 3ph
|
TOSHIBA | Cassette | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.53 | 4.38 | 3.44 | -15° | 14.00 | 8.00 | |
|
RAV-GM1602ATW-E/RAV-HM1601CTP-E
DI
|
TOSHIBA | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.25 | 4.30 | 3.37 | -15° | 14.00 | 8.00 | |
|
RAV-GP1601AT8-E/RAV-HM1601CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.23 | 4.21 | 3.72 | -20° | 14.00 | 12.00 | |
|
RAV-GM1602ATW-E/RAV-HM1601UTP-E
DI
|
TOSHIBA | Cassette | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.40 | 3.39 | -15° | 14.00 | 8.00 | |
|
RAV-GP1401AT8-E1/RAV-HM1401FT-E
SDI 3ph
|
TOSHIBA | Floor standing | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.02 | 3.00 | -20° | 12.50 | 11.80 | |
|
RAV-GM1402ATW-E/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.40 | 3.79 | -15° | 12.10 | 8.00 | |
|
RAV-GP1601AT8-E/RAV-HM1601UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.99 | 4.38 | 3.74 | -20° | 14.00 | 9.50 | |
|
RAV-GP1401AT8-E1/RAV-HM1401CTP-E
SDI 3ph
|
TOSHIBA | Ceiling suspended | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.21 | 4.02 | -20° | 12.50 | 11.80 | |
|
RAV-GP1401AT8-E1/RAV-HM1401UTP-E
SDI 3ph
|
TOSHIBA | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.35 | 4.37 | 4.11 | -20° | 12.50 | 9.50 | |
|
RAV-GP1401AT-E1/RAV-HM1401BTP-E
SDI
|
TOSHIBA | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.28 | 3.86 | -27° | 12.50 | 9.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401CTP-E
SDI
|
TOSHIBA | Ceiling suspended | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.99 | 4.73 | 3.90 | -27° | 12.50 | 9.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401FT-E
SDI
|
TOSHIBA | Floor standing | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.49 | 4.38 | 3.00 | -27° | 12.30 | 9.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401UTP-E
SDI
|
TOSHIBA | Cassette | 93 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.59 | 4.74 | 4.36 | -27° | 12.50 | 9.60 | |
|
RAV-GP1401AT-E1/RAV-HM1401UT-E
SDI
|
TOSHIBA | Cassette | 96 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.87 | 5.00 | 4.61 | -27° | 12.50 | 9.60 |