Manufacturer:
CIAT
Inventor
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(2)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(285)
EQUATION
(0)
FUJI ELECTRIC
(29)
FUJITSU
(79)
Fujitsu Atlantic
(41)
GENERAL
(40)
GREE
(0)
GSS
(0)
HAIER
(130)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(22)
IVT
(0)
KAYSUN
(23)
LG
(59)
MIDEA
(114)
MITSUBISHI ELECTRIC
(132)
Mitsubishi Heavy Industries
(168)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
Rotenso
(8)
SAMSUNG
(24)
THERMOR
(0)
TOSHIBA
(49)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(5)-42
ODU + Wall Mounted
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.70 | 2.83 | -10° | 12.10 | 8.70 | |
|
U6RSL(5)-42
ODU + Cassette
|
Inventor | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.20 | -10° | 12.30 | 9.00 | |
|
U6RSL(5)-42
ODU + Wall Mounted
|
Inventor | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 2.80 | -10° | 12.10 | 8.60 | |
|
U7iRT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
U7iRT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
U7iRT-66/V7iFI-66
Floor Standing
|
Inventor | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
42HK48VDS8C/38HU48VDT8C
Cassette
|
CIAT | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.49 | 14.00 | 10.80 | ||
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U7RT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
42HK42VDS8C*/38HU42VDS8C*
Cassette
|
CIAT | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.59 | 12.10 | 9.50 | ||
|
U7RS-42/V7CI-42WiFiR
Cassette R32
|
Inventor | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
U7RT-50/V7DI-50WiFiR
Ducted R32
|
Inventor | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
42HU60VDS8C/38HU60VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.05 | 15.50 | 12.00 | ||
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
42HK60VDS8C/38HU60VDT8C
Cassette
|
CIAT | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.21 | 15.00 | 11.80 | ||
|
42HU48VDS8C/38HU48VDT8C
Ceiling suspended
|
CIAT | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.06 | 14.00 | 11.20 | ||
|
U7RT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -10° | 15.30 | 11.90 | |
|
V6FO-60/V6FI-60
Floor Standing
|
Inventor | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.70 | 3.75 | -10° | 14.00 | 10.79 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
U7iRT-50/V7iDI-50WiFiR
Ducted R32
|
Inventor | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
U7RS-42/V7DI-42WiFiR
Ducted R32
|
Inventor | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
42HY48VDS8C/38HU48VDT8C
Ducted
|
CIAT | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.44 | 14.10 | 11.70 | ||
|
U7RS-42/V7iDI-42WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
42HY42VDS8C*/38HU42VD8C*
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.00 | 3.91 | 12.10 | 9.30 | ||
|
42HY60VDS8C/38HU60VDT8C
Ducted
|
CIAT | Ducted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.52 | 15.40 | 12.70 | ||
|
U7RT-60/V7DI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7iDI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 |