Filters · 4 active
Manufacturer:
COLIBRI
LG
Rotenso
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(2)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
CIAT
(8)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(285)
EQUATION
(0)
FUJI ELECTRIC
(29)
FUJITSU
(79)
Fujitsu Atlantic
(41)
GENERAL
(40)
GREE
(0)
GSS
(0)
HAIER
(130)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(22)
IVT
(0)
Inventor
(25)
KAYSUN
(23)
MIDEA
(114)
MITSUBISHI ELECTRIC
(132)
Mitsubishi Heavy Industries
(168)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
SAMSUNG
(24)
THERMOR
(0)
TOSHIBA
(49)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(8)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AUUW486D2/APNH48GTLA0
UU
|
LG | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.05 | 3.51 | 3.41 | 13.40 | 11.50 | ||
|
UU48W U32 / UP48 NT3
UU
|
LG | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.05 | 3.51 | 3.41 | 13.40 | 11.50 | ||
|
UU49W U32 / UP48 NT3
UU
|
LG | Floor standing | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.05 | 3.51 | 3.41 | 13.40 | 11.50 | ||
|
FM56AH.U34 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
FM57AH.U34/CT18F.NQ0/CT18F.NQ0/CT18F.NQ0 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
A9UW56GFA1 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
FM56AH.U34
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 15.50 | 9.50 | ||
|
FM57AH.U34/CT18F.NQ0/CT18F.NQ0/CT18F.NQ0
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 15.50 | 9.50 | ||
|
A9UW56GFA1
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 15.50 | 9.50 | ||
|
FM40AH.U34
MU
|
LG | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.30 | 12.10 | 8.60 | ||
|
FM41AH.U34
MU
|
LG | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.30 | 12.10 | 8.60 | ||
|
T140Xi R16/UO140Xo R15
Tenji
|
Rotenso | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
UUD1 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N20
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD1 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
UUD3 U30 / UM42F N21
UU
|
LG | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.60 | 3.90 | 3.61 | -10° | 12.00 | 9.50 | |
|
T160Xi R16/UO160Xo R15
Tenji
|
Rotenso | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
T120Xi R16/UO120Xo R14
Tenji
|
Rotenso | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
UUD1 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
UUD3 U30 / UV60F N20
UU
|
LG | Ceiling suspended | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 4.10 | 3.00 | 14.40 | 9.50 | ||
|
UUD1 U30 / UM60F N30
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD3 U30 / UM60F N30
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZBNW60GM3A1
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD1 U30 / UM60F N31
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
UUD3 U30 / UM60F N31
UU
|
LG | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.00 | 3.65 | 14.60 | 9.50 | ||
|
J160Xi R14/UO160Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
J140Xi R14/UO140Xo R15
Jato
|
Rotenso | Ceiling/Floor | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
UUD1 U30 / UV48F N20
UU
|
LG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.25 | 13.40 | 9.50 | ||
|
UUD3 U30 / UV48F N20
UU
|
LG | Ceiling suspended | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.90 | 4.10 | 3.25 | 13.40 | 9.50 | ||
|
UUD1 U30 / UM48F N30
UU
|
LG | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.60 | 13.40 | 9.50 | ||
|
UUD3 U30 / UM48F N30
UU
|
LG | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.60 | 13.40 | 9.50 | ||
|
UUD1 U30 / UM48F N31
UU
|
LG | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.60 | 13.40 | 9.50 | ||
|
UUD3 U30 / UM48F N31
UU
|
LG | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.60 | 13.40 | 9.50 | ||
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
N140Xi R15/UO140Xo R15
Nevo
|
Rotenso | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
UUD1 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD3 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD1 U30TK / ZTNW48GALA1
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD1 U30 / UT48F NY0
UU
|
LG | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.40 | 13.40 | 9.00 | ||
|
UUD3 U30 / UT48F NY0
UU
|
LG | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.40 | 13.40 | 9.00 | ||
|
UUD1 U30TK / ZTNW48GYLA0
UU
|
LG | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.40 | 13.40 | 9.00 | ||
|
N120Xi R15/UO120Xo R14
Nevo
|
Rotenso | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
FM48AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM49AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM48AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM49AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 |