Filters · 9 active
Manufacturer:
BOSCH
COLIBRI
Candy
Inventor
PANASONIC
SAMSUNG
Vulcano
WESTPOINT
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(2)
AUX
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
CIAT
(8)
CONFORT AIR
(0)
DAIKIN
(285)
DE DIETRICH
(0)
EQUATION
(0)
FUJI ELECTRIC
(29)
FUJITSU
(79)
Fujitsu Atlantic
(41)
GENERAL
(40)
GREE
(0)
GSS
(0)
HAIER
(130)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(22)
IVT
(0)
KAYSUN
(23)
LG
(60)
MIDEA
(114)
MITSUBISHI ELECTRIC
(132)
Mitsubishi Heavy Industries
(168)
NORD
(4)
Nobu
(0)
PITSOS
(0)
RIELLO
(9)
Rotenso
(8)
THERMOR
(0)
TOSHIBA
(49)
Viessmann
(0)
XTRON
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
U6RSL(5)-42
ODU + Wall Mounted
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.70 | 2.83 | -10° | 12.10 | 8.70 | |
|
U6RSL(5)-42
ODU + Cassette
|
Inventor | Cassette | 12 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.90 | 3.20 | -10° | 12.30 | 9.00 | |
|
U-140PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.78 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
U-140PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
U6RSL(5)-42
ODU + Wall Mounted
|
Inventor | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 2.80 | -10° | 12.10 | 8.60 | |
|
U-125PZH4E5 / S-2545PK4E(3x)
2024
|
PANASONIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.79 | 3.71 | -20° | 12.20 | 9.50 | |
|
U-125PZH4E8 / S-2545PK4E(3x)
2024
|
PANASONIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.79 | 3.71 | -20° | 12.20 | 9.50 | |
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
U-140PZH4E5 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-125PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
U7iRT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
U-125PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.12 | 3.76 | 3.89 | -15° | 12.50 | 12.50 | |
|
U7iRT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
U7iRT-66/V7iFI-66
Floor Standing
|
Inventor | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
AC120RXADKG/AC120RN4DKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.18 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RN4DKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC120RXADKG/AC120RN4PKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RN4PKG
CAC
|
SAMSUNG | Cassette | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.26 | -20° | 12.00 | 6.50 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U-140PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
U-140PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.26 | 3.85 | 3.71 | -15° | 13.40 | 12.00 | |
|
U7RT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
U-140PZ3E8 / S-1014PU3E
2021
|
PANASONIC | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.49 | 3.89 | 4.18 | -15° | 14.00 | 14.00 | |
|
U-140PZ3E5 / S-1014PU3E
2021
|
PANASONIC | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.51 | 3.89 | 4.18 | -15° | 14.00 | 14.00 | |
|
U7RS-42/V7CI-42WiFiR
Cassette R32
|
Inventor | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
U7RT-50/V7DI-50WiFiR
Ducted R32
|
Inventor | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
U-140PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.37 | 3.60 | 3.76 | -15° | 13.40 | 9.50 | |
|
U-140PZ3E5 / S-1014PF3E
2021
|
PANASONIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.39 | 3.60 | 3.76 | -15° | 13.40 | 9.50 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
U7RT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -10° | 15.30 | 11.90 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E5 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140NC5‐PE
2025
|
PANASONIC | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
AC120RXADKG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.42 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNMDKG
CAC
|
SAMSUNG | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.48 | -20° | 12.00 | 6.50 | |
|
U-125PZ3E5 / S-1014PF3E
2021
|
PANASONIC | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.52 | 3.68 | 3.56 | -15° | 12.10 | 9.30 | |
|
U-125PZ3E8 / S-1014PF3E
2021
|
PANASONIC | Ducted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.49 | 3.68 | 3.56 | -15° | 12.10 | 9.30 | |
|
U-125PZ3E5 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
U-125PZ3E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.43 | 3.88 | 3.99 | -15° | 12.50 | 11.00 | |
|
V6FO-60/V6FI-60
Floor Standing
|
Inventor | Floor standing | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.70 | 3.75 | -10° | 14.00 | 10.79 | |
|
AC120RXADKG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.45 | -20° | 12.00 | 6.50 | |
|
AC120RXADNG/AC120RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.00 | 3.47 | -20° | 12.00 | 6.50 | |
|
AC140RXADKG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RNCDKG
CAC
|
SAMSUNG | Ceiling suspended | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.41 | -20° | 13.40 | 8.40 | |
|
AC140RXADKG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.35 | -20° | 13.40 | 8.40 | |
|
AC140RXADNG / AC140RN4PKG
CAC
|
SAMSUNG | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 3.41 | -20° | 13.40 | 8.40 |