Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(16)
CIAT
(6)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(0)
EQUATION
(0)
FUJI ELECTRIC
(1)
FUJITSU
(3)
Fujitsu Atlantic
(3)
GENERAL
(3)
GREE
(0)
GSS
(0)
HAIER
(14)
HEC
(0)
HEIWA
(0)
HISENSE
(4)
HITACHI
(14)
IVT
(0)
Inventor
(19)
KAYSUN
(18)
LG
(21)
MIDEA
(95)
MITSUBISHI ELECTRIC
(0)
Mitsubishi Heavy Industries
(40)
NORD
(0)
Nobu
(0)
PANASONIC
(11)
RIELLO
(6)
Rotenso
(6)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(18)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(6)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG60LATT/ARYG60LHTA
AOYG**L
|
FUJITSU | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
AOHG60LATT/ARHG60LHTA
AOHG**L
|
GENERAL | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
ROG60LATT/RDG60LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
AOYG60LATT/ARYG60LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 4 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.86 | 3.50 | 3.50 | 15.00 | 10.80 | ||
|
RPFC-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Ceiling/Floor | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.30 | 3.78 | 2.64 | -10° | 16.30 | 11.00 | |
|
FDC140VNX/FDF140VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.80 | 3.57 | 3.41 | 14.00 | 13.00 | ||
|
FDC140VSX/FDE140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.56 | 3.62 | 3.41 | 14.00 | 15.50 | ||
|
RCI-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Cassette | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 3.75 | 3.19 | -10° | 14.00 | 13.00 | |
|
FDC140VNX/FDE140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.41 | 3.66 | 3.41 | 14.00 | 13.00 | ||
|
FDC140VSX/FDF140VD
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Floor standing | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.94 | 3.61 | 3.41 | 14.00 | 14.30 | ||
|
RCI-6.5UFE1NH/RAS-6.5UFESMH1
Primairy R32 series
|
HITACHI | Cassette | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.87 | 2.89 | -10° | 16.90 | 13.50 | |
|
RPFC-6.0UFE1NH/RAS-6.0UFESNH1
Primairy R32 series
|
HITACHI | Ceiling suspended | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.45 | 3.68 | 3.06 | -10° | 14.00 | 12.00 | |
|
U-140PZ3E8 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.78 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
RAV-GM1602AT8W-E/RAV-HM1601FT-E
DI 3ph
|
TOSHIBA | Floor standing | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.15 | 3.82 | 2.83 | -15° | 14.00 | 8.30 | |
|
U-140PZ3E5 / S-1014PT3E
2021
|
PANASONIC | Ceiling suspended | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.80 | 3.71 | 3.70 | -15° | 14.00 | 13.60 | |
|
AP160S2SE1FA(H)/1U160S2SP1FB
R32 Super Match Plus - Cabinet
|
HAIER | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 4.00 | 3.10 | 15.00 | 11.00 | ||
|
AOYG54LATT/ABYG54LRTA
AOYG**L
|
FUJITSU | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.72 | 3.93 | 3.43 | 14.00 | 10.40 | ||
|
AOHG54LATT/ABHG54LRTA
AOHG**L
|
GENERAL | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.72 | 3.93 | 3.43 | 14.00 | 10.40 | ||
|
AOYG54LATT/ABYG54LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.72 | 3.93 | 3.43 | 14.00 | 10.40 | ||
|
ADH160H1ERG/1U160S2SP1FB
R32 Super Match Plus - Duct
|
HAIER | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 4.00 | 3.10 | 15.00 | 11.00 | ||
|
AP160S2SK1FA(H)/1U160S2SP1FB
R32 Super Match Plus - Cabinet
|
HAIER | Cassette | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 4.00 | 3.10 | 15.00 | 11.00 | ||
|
ABH160K1ERG/1U160S2SP1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.96 | 3.99 | 3.04 | 15.00 | 11.00 | ||
|
ABH160K1ERG(H)/1U160S2SP1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.96 | 3.99 | 3.04 | 15.00 | 11.00 | ||
|
AB160S2SR1FA(H)/1U160S2SP1FB
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.96 | 3.99 | 3.04 | 15.00 | 11.00 | ||
|
FDC140VNX/FDUM140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
FM56AH.U34 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
FM57AH.U34/CT18F.NQ0/CT18F.NQ0/CT18F.NQ0 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
A9UW56GFA1 [EAU609054**]
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 14.70 | 9.50 | ||
|
FM56AH.U34
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 15.50 | 9.50 | ||
|
FM57AH.U34/CT18F.NQ0/CT18F.NQ0/CT18F.NQ0
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 15.50 | 9.50 | ||
|
A9UW56GFA1
MU
|
LG | Cassette | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.10 | 15.50 | 9.50 | ||
|
RAV-GM1602ATW-E/RAV-HM1601FT-E
DI
|
TOSHIBA | Floor standing | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.20 | 3.90 | 2.83 | -15° | 14.00 | 8.30 | |
|
FDC140VNX/FDU140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.85 | 3.62 | 14.00 | 13.00 | ||
|
U-200PZH4E8 / S-5010PK4E(2x)
2024
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.07 | 3.87 | 3.71 | -20° | 16.00 | 15.70 | |
|
FDC140VSX/FDUM140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.36 | 3.88 | 3.62 | 14.00 | 15.50 | ||
|
U-140PZH4E5 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
U-140PZH4E8 + P‐VTVF140MC5‐PE
2025
|
PANASONIC | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 3.95 | 3.95 | -20° | 15.11 | 10.96 | |
|
AUV175UR4RC8/AUW175U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.30 | -10° | 16.00 | 10.00 | |
|
FDC140VSX/FDT140VH
VNX/VSX (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.99 | 3.81 | 14.00 | 15.50 | ||
|
U7iRT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
MOX630U-48HFN8-RRD0W(GA)/MCD1-48HRFNX-QRD0W(GA)
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(GA)/MCD1-48HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MO-48N8-R-1/MCD-48NX
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-RRD0W/MCD1-48HRFNX
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(GA)/MCD2-48HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
KUE-140 DTR14/KCIS-140 DR14
Zen
|
KAYSUN | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-RRD0W(GA)/MCD1-48HRFNX-QRD0W(GA)-W
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
T140Xi R16/UO140Xo R15
Tenji
|
Rotenso | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
42QTD048D8S/38QUS048D8TX
Cassette
|
CARRIER | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
MOX630U-48HFN8-R(H)/MCD2-48HRFNX(GA)
Cassette R32
|
MIDEA | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 |