Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(200)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(8)
Fujitsu Atlantic
(4)
GENERAL
(4)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(22)
HITACHI
(8)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(25)
MIDEA
(0)
MITSUBISHI ELECTRIC
(40)
Mitsubishi Heavy Industries
(86)
NORD
(0)
Nobu
(0)
PANASONIC
(18)
RIELLO
(1)
Rotenso
(0)
SAMSUNG
(9)
THERMOR
(0)
TOSHIBA
(22)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GV1601ATP-E1/RAV-HM1601UTP-E
DIC 1ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 4.20 | 3.46 | -15° | 13.00 | 8.00 | |
|
RAV-GM1401AT8P-E1/RAV-HM1401UTP-E
DI 3ph
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
RAV-GM1401ATP-E1/RAV-HM1401UTP-E
DI
|
TOSHIBA | Cassette | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.71 | 4.28 | 3.76 | -15° | 12.10 | 8.00 | |
|
FDC125VNA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
FDC125VSA/FDTC60VH/FDTC60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.54 | 4.36 | 3.08 | 12.50 | 9.80 | ||
|
AZAS140MY1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
AZAS140MV1 / FCAG140B
AZAS
|
DAIKIN | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.31 | 13.00 | 7.80 | |||
|
FDC140VNA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
FDC140VSA-W/FDE140VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.76 | 4.24 | 3.71 | 13.60 | 10.50 | ||
|
UUD1 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD3 U30 / UT60F NA0
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
UUD1 U30TK / ZTNW60GALA1
UU
|
LG | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.30 | 14.60 | 9.50 | ||
|
FDC140VNA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC140VSA/FDT140VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.16 | 4.28 | 3.50 | 13.60 | 10.50 | ||
|
FDC125VNP-W/FDT125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.37 | 4.27 | 3.78 | 12.10 | 8.00 | ||
|
AZAS140MV / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
AZAS140MY / FCAG140B
AZAS
|
DAIKIN | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.31 | 13.40 | 7.80 | |||
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.29 | 4.39 | 12.10 | 6.00 | |||
|
RAV-GM1402AT8W-E/RAV-HM1401CTP-E
DI 3ph
|
TOSHIBA | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.87 | 4.20 | 3.79 | -15° | 12.10 | 8.00 | |
|
RZASG125MV1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
RZASG125MY
RZASG
|
DAIKIN | Cassette | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.30 | 12.10 | 6.00 | |||
|
FDC125VNP-W/FDE125VH
VNP-W (AC2 single)
|
Mitsubishi Heavy Industries | Ceiling suspended | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.95 | 4.21 | 3.67 | 12.10 | 7.90 | ||
|
UUD1 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD3 U30 / UT48F NA0
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
UUD1 U30TK / ZTNW48GALA1
UU
|
LG | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.55 | 13.40 | 9.50 | ||
|
PUZ-SM140VKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140VKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
PUZ-SM140YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.27 | 3.37 | -15° | 13.40 | 9.40 | |
|
UUD1 U30 / UT48F NY0
UU
|
LG | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.40 | 13.40 | 9.00 | ||
|
UUD3 U30 / UT48F NY0
UU
|
LG | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.40 | 13.40 | 9.00 | ||
|
UUD1 U30TK / ZTNW48GYLA0
UU
|
LG | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.40 | 13.40 | 9.00 | ||
|
RZASG140MV1 / FCAG140B
RZASG
|
DAIKIN | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 13.40 | 7.80 | |||
|
RZASG140MY1 / FCAG140B
RZASG
|
DAIKIN | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 13.40 | 7.80 | |||
|
RZASG140MY / FCAG140B
RZASG
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 13.40 | 7.80 | |||
|
RZASG140MV / FCAG140B
RZASG
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 13.40 | 7.80 | |||
|
FM48AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM49AH.U34 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1 [EAU609054**]
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 13.40 | 9.50 | ||
|
FM48AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
FM49AH.U34
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
A8UW48GFA1 / ZTNW24GBLA1 / ZTNW24GBLA1
MU
|
LG | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.50 | 3.40 | 14.00 | 9.50 | ||
|
RZASG125MV1
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
RZASG125MY1
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 | |||
|
RZASG125MV
RZASG
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.26 | 12.10 | 6.00 |