Filters · 4 active
Manufacturer:
COLIBRI
Fujitsu Atlantic
Inventor
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(2)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
CIAT
(8)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(285)
EQUATION
(0)
FUJI ELECTRIC
(29)
FUJITSU
(79)
GENERAL
(40)
GREE
(0)
GSS
(0)
HAIER
(130)
HEC
(0)
HEIWA
(0)
HISENSE
(27)
HITACHI
(22)
IVT
(0)
KAYSUN
(23)
LG
(59)
MIDEA
(114)
MITSUBISHI ELECTRIC
(132)
Mitsubishi Heavy Industries
(168)
NORD
(4)
Nobu
(0)
PANASONIC
(45)
RIELLO
(9)
Rotenso
(8)
SAMSUNG
(24)
THERMOR
(0)
TOSHIBA
(49)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(8)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AOYG45KBTB/AUXG45KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
AOYG45KRTA/AUXG45KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.33 | 4.20 | 12.10 | 9.20 | ||
|
V5MF0-66/V5MFI-66Β
Floor Standing
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.04 | 3.20 | -10° | 14.74 | 11.63 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
AOYG54KBTB/AUXG54KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
AOYG54KRTA/AUXG54KRLB
AUXG**K
|
Fujitsu Atlantic | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.31 | 3.73 | 13.40 | 9.50 | ||
|
U7RT-60/V7DI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.55 | -10° | 15.30 | 12.50 | |
|
U7iRT-60/V7iDI-60WiFiR
Ducted R32
|
Inventor | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 15.30 | 12.50 | |
|
U7RS-42/V7iDI-42WiFiR
Ducted R32
|
Inventor | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.70 | -10° | 12.10 | 9.50 | |
|
U7RS-42/V7DI-42WiFiR
Ducted R32
|
Inventor | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.90 | -10° | 12.10 | 9.50 | |
|
AOYG45KBTB/ARXH45KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXH45KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.60 | 4.10 | 3.62 | 12.10 | 9.20 | ||
|
U7iRT-50/V7iDI-50WiFiR
Ducted R32
|
Inventor | Ducted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.00 | 3.50 | -10° | 14.00 | 11.50 | |
|
AOYG45KRTA/ABYG45KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.25 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
AOYG45LATT/AUYG45LRLA
AOYG**L
|
Fujitsu Atlantic | Cassette | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 4.17 | 3.91 | 12.50 | 10.10 | ||
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
AOYG54KRTA/ARXH54KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.41 | 4.10 | 3.33 | 13.40 | 9.50 | ||
|
AOYG45KBTB/ABYG45KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.24 | 4.05 | 3.52 | 12.10 | 9.20 | ||
|
V6FO-60/V6FI-60
Floor Standing
|
Inventor | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.11 | 3.70 | 3.75 | -10° | 14.00 | 10.79 | |
|
U7RT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 3.22 | -10° | 15.30 | 11.90 | |
|
U7RT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.00 | -10° | 15.50 | 11.90 | |
|
AOYG45KBTB/ARXG45KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KBTB/ARXG45KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 4.00 | 3.74 | 12.10 | 9.20 | ||
|
U7RT-50/V7DI-50WiFiR
Ducted R32
|
Inventor | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.52 | -10° | 14.00 | 11.50 | |
|
U7RS-42/V7CI-42WiFiR
Cassette R32
|
Inventor | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.60 | -10° | 12.10 | 9.50 | |
|
AOYG54LATT/AUYG54LRLA
AOYG**L
|
Fujitsu Atlantic | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.95 | 4.09 | 3.61 | 14.00 | 10.40 | ||
|
U7RT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.50 | -10° | 14.00 | 11.00 | |
|
AOYG45LATT/ABYG45LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.03 | 3.98 | 3.61 | 12.50 | 10.10 | ||
|
U7iRT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.36 | -10° | 14.00 | 11.20 | |
|
U7iRT-60/V7KI-60WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.05 | -10° | 15.30 | 11.80 | |
|
AOYG45KBTB/ARXG45KHTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
AOYG45KRTA/ARXG45KHTAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.83 | 3.87 | 4.01 | 12.10 | 9.20 | ||
|
U7RT-50/V7KI-50WiFiR
Ceiling&Floor R32
|
Inventor | Ceiling suspended | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 3.07 | -10° | 14.00 | 11.20 | |
|
U7iRT-66/V7iFI-66
Floor Standing
|
Inventor | Floor standing | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.70 | 3.80 | 3.24 | -10° | 15.50 | 12.10 | |
|
U7iRT-50/V7CI-50WiFiR
Cassette R32
|
Inventor | Cassette | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.52 | -10° | 14.00 | 11.20 | |
|
U7iRT-60/V7CI-60WiFiR
Cassette R32
|
Inventor | Cassette | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 4.00 | 3.19 | -10° | 15.30 | 11.80 | |
|
AOYG54KBTB/ARXG54KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ARXG54KHTA
ARX**K
|
Fujitsu Atlantic | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
AOYG54KBTB/ARXG54KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ARXG54KHTB
ARX**K
|
Fujitsu Atlantic | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.10 | 3.96 | 3.71 | 13.40 | 9.50 | ||
|
AOYG54KBTB/ARXG54KHTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.85 | 3.98 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ARXG54KHTAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.81 | 3.85 | 3.98 | 13.40 | 9.50 | ||
|
AOYG54KRTA/ABYG54KRTA
ABY**K
|
Fujitsu Atlantic | Ceiling suspended | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.88 | 3.95 | 3.50 | 13.40 | 9.50 | ||
|
U6RSL(5)-42
ODU + Wall Mounted
|
Inventor | Wall mounted | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.80 | 2.80 | -10° | 12.10 | 8.60 | |
|
AOYG54LATT/ABYG54LRTA
AOYG**L
|
Fujitsu Atlantic | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.72 | 3.93 | 3.43 | 14.00 | 10.40 | ||
|
AOYG45LATT
AOY**L
|
Fujitsu Atlantic | Cassette | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.95 | 3.98 | 3.66 | 12.50 | 10.10 |