Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(2)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(19)
CIAT
(8)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(139)
EQUATION
(0)
FUJI ELECTRIC
(29)
FUJITSU
(79)
Fujitsu Atlantic
(41)
GENERAL
(40)
GREE
(0)
GSS
(0)
HAIER
(130)
HEC
(0)
HEIWA
(0)
HISENSE
(21)
HITACHI
(17)
IVT
(0)
Inventor
(25)
KAYSUN
(23)
LG
(57)
MIDEA
(114)
MITSUBISHI ELECTRIC
(116)
Mitsubishi Heavy Industries
(115)
NORD
(4)
Nobu
(0)
PANASONIC
(37)
RIELLO
(9)
Rotenso
(8)
SAMSUNG
(18)
THERMOR
(0)
TOSHIBA
(44)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(8)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAV-GP1401AT-E1/RAV-HM1401FT-E
SDI
|
TOSHIBA | Floor standing | 92 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.49 | 4.38 | 3.00 | -27° | 12.30 | 9.60 | |
|
RAS-6HVNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.99 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Ducted | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.90 | 4.70 | 4.40 | -20° | 14.00 | 14.20 | |
|
AUV125UR4RC8/AUW125U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
AUV125UR4RC8/AUW125U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 91 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.40 | 3.71 | -10° | 12.10 | 9.00 | |
|
FDC140VSA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 88 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
FDC140VNA/FDF71VD1/FDF71VD1
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Floor standing | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.87 | 4.99 | 3.56 | 13.60 | 10.50 | ||
|
RAV-GP1401AT-E1/RAV-HM1401BTP-E
SDI
|
TOSHIBA | Ducted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.77 | 4.28 | 3.86 | -27° | 12.50 | 9.60 | |
|
AUV140UR4RC8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
AUV140UR4RC8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ceiling | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.40 | 4.40 | 3.30 | -10° | 13.50 | 9.00 | |
|
RAS-6HNC2E
UTOPIA PRIME
|
HITACHI | Cassette | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.92 | 4.71 | 4.40 | -20° | 14.00 | 14.20 | |
|
PUZ-ZM125VDA/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125VDA2/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.68 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
AUD140UX4REH8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.50 | 3.72 | -10° | 13.50 | 9.00 | |
|
AUD140UX4REH8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.00 | 4.50 | 3.72 | -10° | 13.50 | 9.00 | |
|
PUZ-ZM125YDA/PEAD-M125JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA/PEAD-M125JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PEAD-M125JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
PUZ-ZM125YDA2/PEAD-M125JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.64 | 4.19 | 3.72 | -20° | 12.50 | 9.30 | |
|
AUD140UX4RQM8/AUW140U4RW8
Turbo Inverter R32
|
HISENSE | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.85 | 4.50 | 3.72 | -10° | 13.50 | 9.00 | |
|
AUD140UX4RQM8/AUW140U6RW8
Turbo Inverter R32
|
HISENSE | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.85 | 4.50 | 3.72 | -10° | 13.50 | 9.00 | |
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MV1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY1
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MV
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
RZASG140MY
RZASG
|
DAIKIN | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.74 | 4.57 | 13.40 | 7.80 | |||
|
PUZ-ZM140VDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.34 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
RZAG125NV1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
RZAG125NY1 / FVA125A
RZAG
|
DAIKIN | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.41 | 4.15 | 12.10 | 9.52 | |||
|
PUZ-ZM140YDA/PSA-M140KA
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PSA-M140KA2
P series
|
MITSUBISHI ELECTRIC | Floor standing | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.33 | 4.06 | 3.00 | -20° | 13.40 | 10.60 | |
|
FDC140VNX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC140VSX/FDUM71VH/FDUM71VH
VNX/VSX (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.62 | 4.38 | 3.68 | 14.00 | 13.00 | ||
|
FDC125VNA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
FDC125VSA/FDUM60VH/FDUM60VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.30 | 4.79 | 3.73 | 12.50 | 9.80 | ||
|
PUZ-ZM140VDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.16 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.16 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140VDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.53 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
FDC140VNA/FDE71VH/FDE71VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.80 | 4.80 | 3.68 | 13.60 | 10.50 | ||
|
PUZ-ZM140YDA/PEAD-M140JA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA/PEAD-M140JAL2
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PEAD-M140JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.49 | 4.15 | 3.90 | -20° | 13.40 | 10.60 | |
|
PUZ-ZM140YDA2/PEAD-M140JAL3
P series
|
MITSUBISHI ELECTRIC | Ducted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.49 | 4.15 | 3.90 | -20° | 13.40 | 10.60 |