Filters · 3 active
Manufacturer:
BOSCH
DAIKIN
AIRCLASS
(1)
AIRWELL
(13)
ATLANTIC
(13)
AUX
(0)
BRYANT
(2)
Buderus
(9)
CARRIER
(23)
CIAT
(3)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(5)
EQUATION
(1)
FUJI ELECTRIC
(36)
FUJITSU
(68)
Fujitsu Atlantic
(40)
GENERAL
(61)
GREE
(29)
GSS
(1)
HAIER
(62)
HEC
(1)
HEIWA
(2)
HISENSE
(80)
HITACHI
(16)
IVT
(2)
Inventor
(25)
KAYSUN
(6)
LG
(54)
MIDEA
(156)
MITSUBISHI ELECTRIC
(50)
Mitsubishi Heavy Industries
(28)
NORD
(8)
Nobu
(2)
PANASONIC
(55)
RIELLO
(4)
Rotenso
(0)
SAMSUNG
(43)
THERMOR
(16)
TOSHIBA
(37)
Viessmann
(3)
Vulcano
(2)
WESTPOINT
(6)
YORK
(4)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
ARXQ25A / ATXQ25A
ARXQ
|
DAIKIN | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.16 | 4.15 | 3.71 | -10° | 2.50 | 2.30 | |
|
RXQ25A / FTXQ25A
RXQ
|
DAIKIN | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.22 | 4.22 | 3.71 | -10° | 2.50 | 2.30 | |
|
ARXF25E / ATXF25E
ARXF
|
DAIKIN | Wall mounted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.73 | -15° | 2.50 | 2.40 | |
|
CL3000i 26 E / CL3000iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 26 E / CL3200iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
ARXF20E / ATXF20E
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXF20F / ATXF20F
ARXF
|
DAIKIN | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.16 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXF25F / ATXF25F
ARXF
|
DAIKIN | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RXF25E / FTXF25E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RXF25F / FTXF25F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.73 | -15° | 2.50 | 2.40 | |
|
RXF20E / FTXF20E
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
RXF20F / FTXF20F
RXF
|
DAIKIN | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.75 | -15° | 2.00 | 2.20 | |
|
ARXC20E / ATXC20E
ARXC
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 3.73 | -14° | 2.10 | 1.90 | |
|
ARXC20D / ATXC20D
ARXC
|
DAIKIN | Wall mounted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.81 | 4.39 | 3.73 | -14° | 2.08 | 1.87 | |
|
RXC20E / FTXC20E
RXC
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.40 | 3.73 | -14° | 2.10 | 1.90 | |
|
RXC20D / FTXC20D
RXC
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.89 | 4.40 | 3.73 | -14° | 2.08 | 1.87 | |
|
ARXC25E / ATXC25E
ARXC
|
DAIKIN | Wall mounted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.40 | 3.76 | -14° | 2.60 | 2.20 | |
|
ARXC25D / ATXC25D
ARXC
|
DAIKIN | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.74 | 4.41 | 3.76 | -14° | 2.57 | 2.23 | |
|
RXC25E / FTXC25E
RXC
|
DAIKIN | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.50 | 3.79 | -14° | 2.60 | 2.20 | |
|
RXC25D / FTXC25D
RXC
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.84 | 4.45 | 3.79 | -14° | 2.57 | 2.23 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
ARXP25N / ATXP25N
ARXP
|
DAIKIN | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.60 | 4.36 | -15° | 2.50 | 2.40 | |
|
ARXP25N9 / ATXP25N9
ARXP
|
DAIKIN | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.90 | 4.60 | 4.36 | -15° | 2.50 | 2.40 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
CL5100i 25 HE/CL5100i W 25 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
RXM25R9 / FNA25A9
RXM
|
DAIKIN | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.60 | 2.80 | |
|
RXM25R9 / FDXM25F9
RXM
|
DAIKIN | Ducted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.40 | 2.60 | |
|
ARXP20N / ATXP20N
ARXP
|
DAIKIN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.64 | 4.77 | -15° | 2.00 | 2.20 | |
|
ARXP20N9 / ATXP20N9
ARXP
|
DAIKIN | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.90 | 4.64 | 4.77 | -15° | 2.00 | 2.20 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
CL6001i 26 E / CL6001iU W 26 E
Climate 6000i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
CL6102i 25 HE / CL6102i W 25 HE
Climate 6102i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
RXP25N / FTXP25N
RXP
|
DAIKIN | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.61 | 4.36 | -15° | 2.50 | 2.40 | |
|
RXP25N9 / FTXP25N9
RXP
|
DAIKIN | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.61 | 4.36 | -15° | 2.50 | 2.40 | |
|
RXP20N / FTXP20N
RXP
|
DAIKIN | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.65 | 4.77 | -15° | 2.00 | 2.20 | |
|
RXP20N9 / FTXP20N9
RXP
|
DAIKIN | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.65 | 4.77 | -15° | 2.00 | 2.20 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CL6000iP 26 / CL6000iP W 26 F
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CLC8001i 25 E / CLC8001i-W 25 E
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
ARXD25A / ATXD25A
ARXD
|
DAIKIN | Wall mounted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.60 | -15° | 2.50 | 2.40 | |
|
RXD25A / FTXD25A
RXD
|
DAIKIN | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.59 | -20° | 2.50 | 2.40 |