Filters · 4 active
Manufacturer:
BOSCH
SAMSUNG
Vulcano
AIRCLASS
(1)
AIRWELL
(13)
ATLANTIC
(13)
AUX
(0)
BRYANT
(2)
Buderus
(9)
CARRIER
(23)
CIAT
(3)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(84)
EQUATION
(1)
FUJI ELECTRIC
(36)
FUJITSU
(68)
Fujitsu Atlantic
(40)
GENERAL
(61)
GREE
(29)
GSS
(1)
HAIER
(62)
HEC
(1)
HEIWA
(2)
HISENSE
(80)
HITACHI
(16)
IVT
(2)
Inventor
(25)
KAYSUN
(6)
LG
(54)
MIDEA
(156)
MITSUBISHI ELECTRIC
(50)
Mitsubishi Heavy Industries
(28)
NORD
(8)
Nobu
(2)
PANASONIC
(55)
RIELLO
(4)
Rotenso
(0)
THERMOR
(16)
TOSHIBA
(37)
Viessmann
(3)
WESTPOINT
(6)
YORK
(4)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
UE-EC 26 / UI-ECU M 26
Easy 3 Cool
|
Vulcano | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
AR40H09C1AMN/AR40H09C1AMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40H09C1BMN/AR40H09C1BMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0AMN/AR40F09C0AMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0BMN/AR40F09C0BMX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR09TXHQASIN/AR09TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR09TXHQBWKN/AR09TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR50F09C1BHN/AR50F09C1BHX
RAC
|
SAMSUNG | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.64 | -11° | 2.50 | 2.10 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
AR09TXFZBWKN/AR09TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.95 | -11° | 2.50 | 2.30 | |
|
CL3000i 26 E / CL3000iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
UE-L2C 26 / UI-L2CU M 26
Line cool
|
Vulcano | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 26 E / CL3200iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
AR60F09C1KWN/AR60F09C1KWX
RAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AR70F09C1DBN/AR70F09C1DBX
RAC
|
SAMSUNG | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
AR70H09CACBN/AR70H09CACBX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AC026RXADKG/AC026TNXDKG
CAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.75 | -20° | 2.60 | 2.10 | |
|
AC026RXADKG/AC026RN1DKG
CAC
|
SAMSUNG | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.26 | -20° | 2.60 | 2.00 | |
|
AR50F09C1AHN/AR50F09C1AHX
RAC
|
SAMSUNG | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
AR50F07C1AHN/AR50F07C1AHX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.68 | -11° | 2.00 | 2.10 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
CL5100i 25 HE/CL5100i W 25 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
AR60F09C1AWN/AR60F09C1AWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
AR60F09CAAWN/AR60F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
AR70H09CACWN/AR70H09CACWX
RAC
|
SAMSUNG | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.60 | 4.21 | -11° | 2.50 | 2.20 | |
|
AR09TXFYBWKN/AR09TXFYBWKX
RAC
|
SAMSUNG | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.74 | -11° | 2.50 | 2.30 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
CL6001i 26 E / CL6001iU W 26 E
Climate 6000i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
CL6102i 25 HE / CL6102i W 25 HE
Climate 6102i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
AR50F09C1CHN/AR50F09C1CHX
RAC
|
SAMSUNG | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CL6000iP 26 / CL6000iP W 26 F
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AR80F09CAAWN/AR80F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
AR80H09CAAWN/AR80H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
CLC8001i 25 E / CLC8001i-W 25 E
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
CL7000i 20 E / CL7000iU W 20 E
Climate 7000i
|
BOSCH | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
CL7000i 20 E / CL7000iU W 20 ES
Climate 7000i
|
BOSCH | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 |