Filters · 8 active
Manufacturer:
ATLANTIC
BOSCH
CIAT
Candy
SAMSUNG
Vulcano
WESTPOINT
AIRCLASS
(1)
AIRWELL
(13)
AUX
(18)
BRYANT
(2)
Buderus
(9)
CARRIER
(27)
COLIBRI
(2)
CONFORT AIR
(1)
DAIKIN
(84)
DE DIETRICH
(4)
EQUATION
(1)
FUJI ELECTRIC
(36)
FUJITSU
(68)
Fujitsu Atlantic
(40)
GENERAL
(61)
GREE
(34)
GSS
(1)
HAIER
(61)
HEC
(1)
HEIWA
(2)
HISENSE
(91)
HITACHI
(16)
IVT
(2)
Inventor
(25)
KAYSUN
(7)
LG
(55)
MIDEA
(156)
MITSUBISHI ELECTRIC
(50)
Mitsubishi Heavy Industries
(28)
NORD
(8)
Nobu
(2)
PANASONIC
(55)
PITSOS
(2)
RIELLO
(4)
Rotenso
(0)
THERMOR
(16)
TOSHIBA
(37)
Viessmann
(3)
XTRON
(1)
YORK
(4)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CY-09RBW-IN/CY-09RBW-OUT
CANDY - R-
|
Candy | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.30 | -10° | 2.40 | 1.90 | |
|
CY-09BRIN/CY-09BROUT
Candy Brezza 2025
|
Candy | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.60 | 1.90 | |
|
CY-09BRIN-N/CY-09BROUT-N
Candy Brezza 2025
|
Candy | Wall mounted | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.30 | -10° | 2.60 | 1.90 | |
|
CL2000 26 E / CL2000U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
UE-EC 26 / UI-ECU M 26
Easy 3 Cool
|
Vulcano | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
CL2001 26 E / CL2001U W 26 E
Climate 2000
|
BOSCH | Wall mounted | 13 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.20 | 4.00 | 4.00 | -10° | 2.80 | 2.60 | |
|
42HF09JS8C/38HF09JS8C
Wall mounted
|
CIAT | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.82 | -10° | 2.80 | 2.60 | |
|
AR40H09C1AMN/AR40H09C1AMX
RAC
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40H09C1BMN/AR40H09C1BMX
RAC
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0AMN/AR40F09C0AMX
RAC
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR40F09C0BMN/AR40F09C0BMX
RAC
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.80 | 2.60 | |
|
AR09TXHQASIN/AR09TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
AR09TXHQBWKN/AR09TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 3.91 | -10° | 2.90 | 2.60 | |
|
CY-09RAIN-A/CY-09RAOUT-A
Candy Pura 2025
|
Candy | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
UI 2,7KW MURAO ACCESS BLANC/UE MONO 2,7KW MURAO ACCESS BLANC
MURAO ACCESS
|
ATLANTIC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.50 | 4.00 | 3.71 | -10° | 2.70 | 2.60 | |
|
AS 007 DBB.UI/ 1U 007 DBR.UE
Dojo
|
ATLANTIC | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.80 | 4.00 | 3.71 | -10° | 2.05 | 1.90 | |
|
AS 009 DBB.UI/ 1U 009 DBRB.UE
Dojo
|
ATLANTIC | Wall mounted | 22 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.71 | -10° | 2.60 | 2.40 | |
|
CL5001L 26 E / CL5001iU 4CC 26 E
Climate 5001 L
|
BOSCH | Cassette | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.09 | -10° | 2.60 | 2.00 | |
|
AR50F09C1BHN/AR50F09C1BHX
RAC
|
SAMSUNG | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 3.64 | -11° | 2.50 | 2.10 | |
|
WIZO-09225.MH / WIZ-09225.MH
WIZ 325
|
WESTPOINT | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.10 | 4.00 | -10° | 2.50 | 2.50 | |
|
WIMO-09225.MH / WIM-09225.MH
WIM 225
|
WESTPOINT | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.33 | -10° | 2.60 | 2.30 | |
|
AR09TXFZBWKN/AR09TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.95 | -11° | 2.50 | 2.30 | |
|
AS 009 NBB.UI/1U 009 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 8.50 | 4.00 | 4.00 | -10° | 2.60 | 2.40 | |
|
42HC09JS8C*/38HC09JS8C*
Wall mounted
|
CIAT | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.85 | -10° | 2.75 | 2.50 | |
|
CL3000i 26 E / CL3000iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
UE-L2C 26 / UI-L2CU M 26
Line cool
|
Vulcano | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
CL3000i 26 E / CL3200iU W 26 E
Climate 3000i
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
ASO09DW31/ASI09DW31
Series 4
|
BOSCH | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.40 | 4.10 | 3.80 | -10° | 2.80 | 2.50 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
AR60F09C1KWN/AR60F09C1KWX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AR70F09C1DBN/AR70F09C1DBX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AR70H09CACBN/AR70H09CACBX
RAC
|
SAMSUNG | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AC026RXADKG/AC026TNXDKG
CAC
|
SAMSUNG | Wall mounted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.75 | -20° | 2.60 | 2.10 | |
|
AC026RXADKG/AC026RN1DKG
CAC
|
SAMSUNG | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.26 | -20° | 2.60 | 2.00 | |
|
AR50F09C1AHN/AR50F09C1AHX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 3.76 | -11° | 2.50 | 2.10 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
AS 007 NBB.UI/1U 007 NBRB.UE
Zenkeo
|
ATLANTIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.00 | -10° | 2.10 | 1.90 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
AR50F07C1AHN/AR50F07C1AHX
RAC
|
SAMSUNG | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.68 | -11° | 2.00 | 2.10 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
UI 2,7 kW MURAO SMART BLANC & UE MONO 2,7 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.47 | 3.71 | -10° | 2.70 | 2.40 | |
|
AS 007 JDB.UI/1U 007 JDB.UE
Kazendo
|
ATLANTIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.75 | 4.20 | 4.80 | -10° | 2.40 | 2.50 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
CL5100i 25 HE/CL5100i W 25 HE
Climate 5100i
|
BOSCH | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
CY-09QBIN-A/CY-09QBOUT-A
Candy Aira 2025
|
Candy | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.71 | -10° | 2.70 | 2.40 | |
|
UI 2,1 kW MURAO SMART BLANC & UE MONO 2,1 kW MURAO SMART BLANC
MURAO SMART
|
ATLANTIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM BLANC & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 | |
|
UI 2,1 kW MURAO PREMIUM NOIR & UE MONO 2,1 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 2.10 | 2.00 |