Manufacturer:
BOSCH
SAMSUNG
Vulcano
AIRCLASS
(1)
AIRWELL
(13)
ATLANTIC
(13)
AUX
(0)
BRYANT
(2)
Buderus
(9)
CARRIER
(23)
CIAT
(3)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(5)
DAIKIN
(84)
EQUATION
(1)
FUJI ELECTRIC
(36)
FUJITSU
(68)
Fujitsu Atlantic
(40)
GENERAL
(61)
GREE
(29)
GSS
(1)
HAIER
(62)
HEC
(1)
HEIWA
(2)
HISENSE
(80)
HITACHI
(16)
IVT
(2)
Inventor
(25)
KAYSUN
(6)
LG
(54)
MIDEA
(156)
MITSUBISHI ELECTRIC
(50)
Mitsubishi Heavy Industries
(28)
NORD
(8)
Nobu
(2)
PANASONIC
(55)
RIELLO
(4)
Rotenso
(0)
THERMOR
(16)
TOSHIBA
(37)
Viessmann
(3)
WESTPOINT
(6)
YORK
(4)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR70H09CAAWN/AR70H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR70H09CAABN/AR70H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 87 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.70 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR70F09CAAWN/AR70F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR70F09CABWN/AR70F09CABWX
RAC
|
SAMSUNG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR50H09C1BHN/AR50H09C1BHX
RAC
|
SAMSUNG | Wall mounted | 86 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.50 | 5.10 | 4.74 | -11° | 2.50 | 2.40 | |
|
AR09TXCACWKN/AR09TXCACWKX
RAC
|
SAMSUNG | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.10 | 4.74 | -11° | 2.50 | 2.30 | |
|
AR09BXFYDWKN/AR09BXFYDWKX
RAC
|
SAMSUNG | Wall mounted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 5.10 | 4.74 | -11° | 2.50 | 2.30 | |
|
CL7000i 26 E / CL7000iU W 26 E
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
CL7000i 26 E / CL7000iU W 26 ES
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
CL7000i 26 E / CL7000iU W 26 EB
Climate 7000i
|
BOSCH | Wall mounted | 83 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 10.10 | 5.10 | 4.70 | -10° | 2.50 | 2.20 | |
|
AR70F07C1AWN/AR70F07C1AWX
RAC
|
SAMSUNG | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 4.80 | 4.78 | -11° | 2.00 | 2.20 | |
|
AR70F07C1ABN/AR70F07C1AWX
RAC
|
SAMSUNG | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 4.80 | 4.78 | -11° | 2.00 | 2.20 | |
|
AR70H07C1ABN/AR70H07C1AWX
RAC
|
SAMSUNG | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 4.80 | 4.78 | -11° | 2.00 | 2.20 | |
|
AR70H07C1AWN/AR70H07C1AWX
RAC
|
SAMSUNG | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.00 | 4.80 | 4.78 | -11° | 2.00 | 2.20 | |
|
CL5100i CNO 25 HE / CL5100i CN 25 HE
Climate 5100i
|
BOSCH | Console | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 4.60 | 4.43 | -10° | 2.60 | 2.80 | |
|
AR70F09C1AWN/AR70F09C1AWX
RAC
|
SAMSUNG | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 4.80 | 4.21 | -11° | 2.50 | 2.30 | |
|
AR70F09C1ABN/AR70F09C1AWX
RAC
|
SAMSUNG | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 4.80 | 4.21 | -11° | 2.50 | 2.30 | |
|
AR70H09C1ABN/AR70H09C1AWX
RAC
|
SAMSUNG | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 4.80 | 4.21 | -11° | 2.50 | 2.30 | |
|
AR70H09C1AWN/AR70H09C1AWX
RAC
|
SAMSUNG | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.80 | 4.80 | 4.21 | -11° | 2.50 | 2.30 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
CL7000i 20 E / CL7000iU W 20 E
Climate 7000i
|
BOSCH | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
CL7000i 20 E / CL7000iU W 20 ES
Climate 7000i
|
BOSCH | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
CL7000i 20 E / CL7000iU W 20 EB
Climate 7000i
|
BOSCH | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.40 | 5.10 | 5.00 | -10° | 2.00 | 1.80 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
CLC8001i 25 E / CLC8001i-W 25 E
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
CLC8001i 25 E / CLC8001i-W 25 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 5.25 | -15° | 2.50 | 2.80 | |
|
AR80F09CAAWN/AR80F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
AR80H09CAAWN/AR80H09CAAWX
RAC
|
SAMSUNG | Wall mounted | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
CL6000iP 26 / CL6000iP W 26 F
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
AR50F09C1CHN/AR50F09C1CHX
RAC
|
SAMSUNG | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 3.95 | -11° | 2.50 | 2.30 | |
|
CL6001i 26 E / CL6001iU W 26 E
Climate 6000i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
CL6102i 25 HE / CL6102i W 25 HE
Climate 6102i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.60 | 4.54 | -10° | 2.60 | 2.40 | |
|
CLC6101i 50 HE / CLC6101i-W 50 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.70 | 4.60 | 4.27 | -20° | 2.50 | 2.80 | |
|
AR09TXFYBWKN/AR09TXFYBWKX
RAC
|
SAMSUNG | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.74 | -11° | 2.50 | 2.30 | |
|
AR70H09CACWN/AR70H09CACWX
RAC
|
SAMSUNG | Wall mounted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.30 | 4.60 | 4.21 | -11° | 2.50 | 2.20 | |
|
AR60F09C1AWN/AR60F09C1AWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
AR60F09CAAWN/AR60F09CAAWX
RAC
|
SAMSUNG | Wall mounted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.90 | 4.60 | 4.16 | -11° | 2.50 | 2.20 | |
|
CL5100i 25 HE/CL5100i W 25 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.20 | -10° | 2.80 | 2.60 | |
|
CL6100i 50 E / CL6100i-W 50 E
Climate 6100i
|
BOSCH | Wall mounted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.60 | 4.31 | -20° | 2.50 | 2.80 | |
|
CL4000i 26 E / CL4000iU W 26 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 4.21 | -10° | 2.90 | 2.40 | |
|
AC026BXAPKG/AC026BNAPKG
CAC HEE
|
SAMSUNG | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.79 | -25° | 2.60 | 2.10 | |
|
AC026BXAPKG/AC026BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.33 | -25° | 2.60 | 2.00 | |
|
AR50F07C1AHN/AR50F07C1AHX
RAC
|
SAMSUNG | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.20 | 4.68 | -11° | 2.00 | 2.10 | |
|
AC026RXADKG/AC026RNJDKG
CAC
|
SAMSUNG | Floor standing | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.20 | 3.30 | -20° | 2.60 | 2.00 | |
|
CL5000i 26 E / CL5000iU W 26 E
Climate 5000i
|
BOSCH | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.20 | 4.35 | -10° | 2.60 | 2.60 | |
|
AR50F09C1AHN/AR50F09C1AHX
RAC
|
SAMSUNG | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.40 | 4.20 | 3.76 | -11° | 2.50 | 2.10 |