Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(6)
ATLANTIC
(8)
AUX
(18)
BOSCH
(10)
BRYANT
(2)
Buderus
(4)
CARRIER
(17)
CIAT
(2)
COLIBRI
(1)
CONFORT AIR
(0)
Candy
(5)
DAIKIN
(28)
DE DIETRICH
(4)
EQUATION
(1)
FUJI ELECTRIC
(17)
FUJITSU
(29)
Fujitsu Atlantic
(16)
GENERAL
(24)
GREE
(18)
GSS
(1)
HAIER
(49)
HEC
(1)
HEIWA
(1)
HISENSE
(64)
HITACHI
(4)
IVT
(0)
Inventor
(16)
KAYSUN
(4)
LG
(37)
MIDEA
(92)
MITSUBISHI ELECTRIC
(17)
Mitsubishi Heavy Industries
(2)
NORD
(7)
Nobu
(2)
PANASONIC
(15)
PITSOS
(2)
RIELLO
(3)
Rotenso
(0)
SAMSUNG
(19)
THERMOR
(16)
TOSHIBA
(11)
Viessmann
(3)
Vulcano
(2)
WESTPOINT
(2)
XTRON
(1)
YORK
(3)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
AS25KBAHRA-MB/1U25MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25KBAHRA-MW/1U25MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
AS25KBAHRA-W/1U25MS3FRA
Coral
|
HAIER | Wall mounted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 5.10 | 4.50 | -10° | 2.60 | 2.40 | |
|
ASW-H09B7A4/MAR3DI-D0 / ASW-H09B7A4/MAR3DI-D0
M SERIES
|
AUX | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 2.70 | 2.30 | |
|
MOST 25 (7886447) / UMT 25 (7886443)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 2.70 | 2.30 | |
|
MOST 25 (7886447) / UMT 2 25 (7906262)
CLIM'UP EVO
|
DE DIETRICH | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.70 | 3.55 | -10° | 2.70 | 2.30 | |
|
RAC-DJ18WHAE / RAK-DJ18RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.20 | -15° | 2.00 | 1.81 | |
|
AS25SBBHRA-MW/1U25DEBFRA-S
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MB/1U25DEBFRA-S
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MWV/1U25DEBFRA-SH
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MW/1U25DEBFRA-SH
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-MB/1U25DEBFRA-SH
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
UI 2,6 kW MURAO PREMIUM BLANC & UE MONO 2,6 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
UI 2,6 kW MURAO PREMIUM NOIR & UE MONO 2,6 kW MURAO PREMIUM BLANC
MURAO PREMIUM
|
ATLANTIC | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
MOX331-09HFN7-QRD6GW/MSAGBU-09HRFN7-QRD6GW(A)
Extreme save R290
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
MOX331-09HFN7-QRD6GW/MSAGBU-09HRFN7-QRD6GW(B)
Extreme save R290
|
MIDEA | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AS25PBBHRA-PA/1U25DEBFRA-S
HAIER-PEARL PREMIUM
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25RBBHRA-RBS/1U25DEBFRA-S
HAIER-TIDE PREMIUM
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SAT1-W/US25SAT1
NORD - S
|
NORD | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
AS25SBBHRA-S/1U25DEBFRA-S
Serene
|
HAIER | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.71 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26 F
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC176iP-2,6 / AC176iP-2,6 W
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
CL6000iP 26 / CL6000iP W 26
Climate 6000iP
|
BOSCH | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
AC176iP-2,6 / AC176iP-2,6 W S
AC176iP
|
Buderus | Wall mounted | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.80 | 4.60 | 3.75 | -10° | 2.60 | 2.50 | |
|
RXP20N / FTXP20N
RXP
|
DAIKIN | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.65 | 4.77 | -15° | 2.00 | 2.20 | |
|
RXP20N9 / FTXP20N9
RXP
|
DAIKIN | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.65 | 4.77 | -15° | 2.00 | 2.20 | |
|
MOX230-09HFN8-QRD1W(GA)/MTJ-09HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MOX230-09HFN8-Q(GA)/MTJ-09HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MO-09N8-Q/MTJU-09HNX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
KUE-26 DVR14/KPD-26 DR15
Duct R32
|
KAYSUN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
DDMD-025N-09M25/YDAX-025R-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
42QSV009D8S*/38QUS009D8SX*
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
AF25S2SD1FA/1U25S2SM1FA-2
Console-Monosplit
|
HAIER | Console | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.00 | 4.20 | 3.73 | -10° | 2.50 | 2.40 | |
|
RXP25N / FTXP25N
RXP
|
DAIKIN | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.61 | 4.36 | -15° | 2.50 | 2.40 | |
|
RXP25N9 / FTXP25N9
RXP
|
DAIKIN | Wall mounted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.20 | 4.61 | 4.36 | -15° | 2.50 | 2.40 | |
|
AOEH09KMCG/ASEH09KMCG
ASE**K
|
FUJITSU | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYH09KMCG/ASYH09KMCG
ASY**K
|
FUJITSU | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCG
ASH**K
|
GENERAL | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
ROH09KMCG/RSH09KMCG
RS**K
|
FUJI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYH09KMCG/ASYH09KMCG-B
ASY**K
|
FUJITSU | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCG-B
ASH**K
|
GENERAL | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOEH09KMCG/ASEH09KMCG-B
ASE**K
|
FUJITSU | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
ROH09KMCG/RSH09KMCG-B
RS**K
|
FUJI ELECTRIC | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCH-B
ASH**K
|
GENERAL | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOHH09KMCG/ASHH09KMCH
ASH**K
|
GENERAL | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 | |
|
AOYH09KMCG/ASYH09KMCG
ASY**K
|
Fujitsu Atlantic | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.40 | 4.60 | 4.52 | -15° | 2.50 | 2.40 |