Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(0)
AUX
(0)
BOSCH
(2)
BRYANT
(0)
Buderus
(0)
CARRIER
(2)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(3)
EQUATION
(0)
FUJI ELECTRIC
(4)
FUJITSU
(8)
Fujitsu Atlantic
(4)
GENERAL
(4)
GREE
(0)
GSS
(0)
HAIER
(6)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(2)
IVT
(0)
Inventor
(0)
KAYSUN
(1)
LG
(3)
MIDEA
(6)
MITSUBISHI ELECTRIC
(8)
Mitsubishi Heavy Industries
(1)
NORD
(1)
Nobu
(0)
PANASONIC
(4)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(4)
THERMOR
(2)
TOSHIBA
(4)
Viessmann
(2)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
RAC-VJ25NHAE / RAD-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Ducted | 89 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.50 | 4.28 | 4.00 | -15° | 2.50 | 2.57 | |
|
AUW26U4RS8/ADT26UX4RBL8
Turbo Inverter R32
|
HISENSE | Ducted | 85 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.32 | -10° | 2.60 | 3.00 | |
|
AC026BXAPKG/AC026BNNPKG
CAC HEE
|
SAMSUNG | Cassette | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.10 | 4.30 | 4.00 | -25° | 2.60 | 2.10 | |
|
AOYG09KBTB/ARXG09KLLAP
ARY**K
|
FUJITSU | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/ARXG09KLLAP
ARH**K
|
GENERAL | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RDG09KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/ARXG09KLLAP
ARXG**K
|
FUJITSU | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/ARXG09KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.20 | 4.30 | 4.05 | -15° | 2.50 | 2.60 | |
|
AC026RXADKG/AC026RNNDKG
CAC
|
SAMSUNG | Cassette | 80 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.30 | 3.69 | -20° | 2.60 | 2.10 | |
|
AUW26U4RS8/ACT26UR4RCC8
Turbo Inverter R32
|
HISENSE | Cassette | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 4.60 | 4.27 | -10° | 2.60 | 3.00 | |
|
CU-Z25CBEA / CS-Z25CD3EAW
2025
|
PANASONIC | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOHG09KBTB/AUXG09KVLA
AUH**K
|
GENERAL | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
ROG09KBTB/RCG09KVLA
RC**K
|
FUJI ELECTRIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOEG09KBTB/AUXG09KVLA
AUXG**K
|
FUJITSU | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
AOYG09KBTB/AUXG09KVLA
AUY**K
|
Fujitsu Atlantic | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.40 | 4.05 | -15° | 2.50 | 2.60 | |
|
U-25PZ3E5 / S-25PY3E
2022
|
PANASONIC | Cassette | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.60 | 4.44 | -15° | 2.50 | 2.80 | |
|
MOX230-09HFN8-QRD1W(GA)/MTJ-09HWFNX-QRD1W(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MOX230-09HFN8-Q(GA)/MTJ-09HWFNX(GA)
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
MO-09N8-Q/MTJU-09HNX
Duct R32
|
MIDEA | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
KUE-26 DVR14/KPD-26 DR15
Duct R32
|
KAYSUN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
DDMD-025N-09M25/YDAX-025R-09M25**
DDMD
|
AIRWELL | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
42QSV009D8S*/38QUS009D8SX*
Ducted
|
CARRIER | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
Vitoclima100-SIDHAA100MFA027/Vitoclima100-SPROOFAA100MFP027
Ducted
|
Viessmann | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CL5001L 26 E / CL5001iU D 26 E
Climate 5001 L
|
BOSCH | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.85 | -10° | 2.60 | 2.10 | |
|
CU-Z25UBEA / CS-Z25UD3EAW
2017
|
PANASONIC | Ducted | 63 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.90 | 4.20 | 4.00 | -15° | 2.50 | 2.60 | |
|
RAV-GM302ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.13 | 4.57 | 4.47 | -15° | 2.50 | 2.30 | |
|
RAV-GM302ATP-E/RAV-HM301SDTY-E
DI
|
TOSHIBA | Ducted | 60 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 5.73 | 4.21 | 3.95 | -15° | 2.50 | 2.60 | |
|
RXM25R9 / FDXM25F9
RXM
|
DAIKIN | Ducted | 60 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.40 | 2.60 | |
|
CU-Z25UBEA / CS-Z25UB4EAW
2017
|
PANASONIC | Cassette | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 4.05 | -15° | 2.50 | 2.70 | |
|
RXM25R9 / FNA25A9
RXM
|
DAIKIN | Ducted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.68 | 4.24 | 4.00 | -15° | 2.60 | 2.80 | |
|
RAV-GM301ATP-E/RAV-HM301MUTP-E
DI
|
TOSHIBA | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.31 | 4.54 | 4.47 | -15° | 2.50 | 2.30 | |
|
RAC-VJ25NHAE / RAI-VJ25RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.30 | 4.00 | -15° | 2.50 | 2.78 | |
|
SUZ-M25VA/MLZ-KP25VF
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/MLZ-KP25VG
S series
|
MITSUBISHI ELECTRIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.40 | 4.00 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA/SLZ-M25FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
SUZ-M25VA2/SLZ-M25FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.30 | 3.61 | -10° | 2.50 | 2.20 | |
|
AB25S2SC2FA/1U25S2SM1FA-2
R32 Super Match Plus - Cassette
|
HAIER | Cassette | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.47 | 3.71 | -10° | 2.50 | 2.80 | |
|
RXM25R9 / FFA25A9
RXM
|
DAIKIN | Cassette | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.17 | 4.24 | 3.90 | -15° | 2.50 | 2.31 | |
|
UUA1 UL0 / UT09FH NQ0
UU
|
LG | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
AC026RXADKG/AC026RN1DKG
CAC
|
SAMSUNG | Cassette | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.00 | 3.26 | -20° | 2.60 | 2.00 | |
|
UUA1 UL0 / CL09F N50
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 4.30 | -10° | 2.50 | 2.90 | |
|
SRC25ZS-W2/FDTC25VH1
ZS-W
|
Mitsubishi Heavy Industries | Cassette | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.00 | 4.08 | -10° | 2.50 | 2.40 | |
|
AD25S2SS1FA/1U25S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 41 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 2.50 | 2.80 | |
|
AB25S2SA1FA/1U25S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
AB25S2SA1FA(H)/1U25S2SM1FA-2
R32 Super Match Plus-1-way cassette
|
HAIER | Cassette | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.20 | 3.72 | -10° | 2.60 | 2.10 | |
|
AC026RXADKG/AC026BNLDKG
CAC
|
SAMSUNG | Ducted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.79 | -20° | 2.60 | 2.00 | |
|
UUA1 UL0 / CT09F NR0
UU
|
LG | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.00 | 4.30 | -10° | 2.50 | 2.80 | |
|
SUZ-M25VA/SEZ-M25DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.61 | -10° | 2.50 | 2.20 |