Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(16)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(2)
HEC
(0)
HEIWA
(0)
HISENSE
(1)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(1)
MIDEA
(0)
MITSUBISHI ELECTRIC
(16)
Mitsubishi Heavy Industries
(13)
NORD
(0)
Nobu
(0)
PANASONIC
(16)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(1)
THERMOR
(0)
TOSHIBA
(2)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC250VSA/FDU250VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.82 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
FDC250VSA/FDU250VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.83 | 3.52 | 3.75 | 24.00 | 14.20 | ||
|
ADH250H1ERG/1UH250W1ERK
Smart Power - Duct
|
HAIER | Ducted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.97 | 3.50 | 3.43 | 23.50 | 13.00 | ||
|
FDC200VSA/FDU200VH
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.06 | 3.52 | 3.71 | 19.00 | 12.50 | ||
|
FDC200VSA/FDU200VG
VNA/VSA (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 7 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.07 | 3.52 | 3.71 | 19.00 | 12.50 | ||
|
FDC250VSA-W/FDU250VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 8 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.90 | 3.54 | 3.75 | 25.00 | 14.20 | ||
|
FDC200VSA-W/FDU200VH
VNA-W/VSA-W (AC2 single)
|
Mitsubishi Heavy Industries | Ducted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.55 | 3.95 | 20.00 | 13.70 | ||
|
ADH200H1ERG/1UH200W1ERK
Smart Power - Duct
|
HAIER | Ducted | 14 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.82 | 3.43 | 20.50 | 13.00 | ||
|
PUHZ-SHW230YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.81 | 3.51 | 3.47 | -25° | 19.00 | 23.00 | |
|
AC200KNHPKH / AC200KXAPNH
CAC
|
SAMSUNG | Ducted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.20 | 3.50 | 3.45 | -20° | 20.00 | 17.50 | |
|
PUZ-M200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.48 | 3.61 | 3.40 | -20° | 19.00 | 15.50 | |
|
UU200W U80A0 / UB200 N80
UU
|
LG | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.14 | 3.83 | 4.00 | 20.00 | 17.60 | ||
|
PUZ-M200YDA/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 3.77 | 3.40 | -20° | 19.00 | 15.50 | |
|
U-200PZH4E8 / S-200PE4E
2024
|
PANASONIC | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.02 | 3.85 | 3.55 | 19.00 | 14.50 | ||
|
PUZ-M250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.39 | 3.56 | 3.30 | -20° | 22.00 | 20.20 | |
|
PUZ-M250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.03 | 4.16 | 3.19 | -20° | 22.00 | 20.20 | |
|
PUZ-ZM250YKA2/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
PUZ-ZM250YKA3/PEA-M250LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.42 | 3.57 | 3.40 | -20° | 22.00 | 20.20 | |
|
RAV-GM2243AT8P-E/RAV-RM2241DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 3.80 | 3.24 | -10° | 19.00 | 11.40 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.32 | 3.89 | 3.89 | 19.00 | 11.20 | ||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.64 | 3.85 | 3.85 | 19.00 | 11.20 | ||
|
U-200PZH4E8 / S-5010PK4E(3x)
2024
|
PANASONIC | Wall mounted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.41 | 3.89 | 3.71 | -20° | 17.50 | 15.70 | |
|
RZA200D
RZA
|
DAIKIN | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.91 | 3.85 | 19.00 | 11.20 | |||
|
PUZ-ZM200YKA3/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.61 | 3.50 | -20° | 19.00 | 18.90 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.85 | 3.82 | 19.00 | 11.20 | |||
|
PUZ-ZM200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.62 | 3.50 | -20° | 19.00 | 18.90 | |
|
AUD200UX4RPH8/AUW200U6RZ8
Turbo Inverter R32
|
HISENSE | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -10° | 19.00 | 17.00 | |
|
RZA200D
RZA
|
DAIKIN | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.82 | 3.90 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.95 | 4.10 | 22.00 | 12.10 | |||
|
U-250PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.48 | 3.90 | 3.80 | -20° | 22.00 | 16.70 | |
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.83 | 3.93 | 19.00 | 11.20 | |||
|
U-250PZH4E8 + P‐VTVF250MC5‐PE
2025
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
RZA200D
RZA
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.16 | 4.10 | 19.00 | 11.20 | |||
|
U-200PZH4E8 / S-6071PF3E(3x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PF3E(4x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
PUZ-ZM250YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.12 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.28 | 4.11 | 3.50 | -10° | 20.00 | 11.40 | |
|
PUZ-ZM250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.13 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 22.00 | 12.10 | |||
|
FDC250VSA-W/FDT125VH/FDT125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.35 | 3.80 | 25.00 | 14.20 | ||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.01 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.10 | 19.00 | 11.20 | |||
|
U-200PZH4E8 / S-5010PK4E(4x)
2024
|
PANASONIC | Wall mounted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.10 | 3.94 | 3.80 | -20° | 19.00 | 15.70 | |
|
PUZ-M250YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.07 | 4.34 | 3.50 | -20° | 22.00 | 17.00 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.15 | 19.00 | 11.20 | |||
|
FDC250VSA-W/FDE125VH/FDE125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.25 | 3.53 | 25.00 | 14.20 | ||
|
FDC200VSA-W/FDT100VH/FDT100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.63 | 4.55 | 4.25 | 20.00 | 12.50 |