Filters · 3 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(17)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(0)
Fujitsu Atlantic
(0)
GENERAL
(0)
GREE
(0)
GSS
(0)
HAIER
(0)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(0)
MIDEA
(0)
MITSUBISHI ELECTRIC
(9)
Mitsubishi Heavy Industries
(10)
NORD
(0)
Nobu
(0)
PANASONIC
(0)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(4)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-M200YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.18 | 4.35 | 3.60 | -20° | 19.00 | 15.50 | |
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
FDC200VSA/FDT100VH/FDT100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.37 | 4.58 | 3.72 | 19.00 | 12.50 | ||
|
PUZ-ZM200YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.46 | 3.79 | -20° | 19.00 | 18.90 | |
|
PUZ-ZM200YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.46 | 3.79 | -20° | 19.00 | 18.90 | |
|
FDC200VSA-W/FDE100VH/FDE100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.53 | 3.96 | 20.00 | 12.50 | ||
|
PUZ-M200YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.94 | 4.20 | 3.30 | -20° | 19.00 | 15.50 | |
|
FDC200VSA-W/FDT100VH/FDT100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 69 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.63 | 4.55 | 4.25 | 20.00 | 12.50 | ||
|
FDC250VSA-W/FDE125VH/FDE125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.25 | 3.53 | 25.00 | 14.20 | ||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.15 | 19.00 | 11.20 | |||
|
PUZ-M250YDA
P series
|
MITSUBISHI ELECTRIC | Cassette | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.07 | 4.34 | 3.50 | -20° | 22.00 | 17.00 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.01 | 4.10 | 19.00 | 11.20 | |||
|
FDC250VSA-W/FDT125VH/FDT125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.35 | 3.80 | 25.00 | 14.20 | ||
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 22.00 | 12.10 | |||
|
PUZ-ZM250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.13 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.39 | 4.10 | 22.00 | 12.10 | |||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.28 | 4.11 | 3.50 | -10° | 20.00 | 11.40 | |
|
FDC250VSA/FDE125VH/FDE125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.45 | 3.58 | 24.00 | 14.20 | ||
|
PUZ-ZM250YKA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.12 | 4.38 | 3.54 | -20° | 22.00 | 20.20 | |
|
RZA200D
RZA
|
DAIKIN | Cassette | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.16 | 4.10 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.95 | 4.10 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 22.00 | 12.10 | |||
|
RZA200D
RZA
|
DAIKIN | Cassette | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.53 | 4.10 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.44 | 4.10 | 22.00 | 12.10 | |||
|
FDC250VSA/FDT125VH/FDT125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.79 | 4.32 | 3.78 | 24.00 | 14.20 | ||
|
RZA200D
RZA
|
DAIKIN | Cassette | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.32 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.64 | 3.85 | 3.85 | 19.00 | 11.20 | ||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.32 | 3.89 | 3.89 | 19.00 | 11.20 | ||
|
RZA200D
RZA
|
DAIKIN | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Cassette | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 22.00 | 12.10 | |||
|
RAV-GM2243AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.32 | 3.86 | 3.24 | -10° | 20.00 | 11.40 | |
|
FDC280VSA-W/FDT140VH/FDT140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Cassette | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.21 | 4.22 | 3.35 | 27.00 | 17.80 | ||
|
RZA200D
RZA
|
DAIKIN | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.79 | 3.90 | 3.90 | 19.00 | 11.20 | ||
|
PUZ-M250YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.03 | 4.16 | 3.19 | -20° | 22.00 | 20.20 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Cassette | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.36 | 3.95 | 3.33 | -10° | 23.50 | 12.30 | |
|
RZA200D
RZA
|
DAIKIN | Cassette | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.77 | 3.84 | 19.00 | 11.20 | |||
|
FDC280VSA-W/FDE140VH/FDE140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.92 | 3.95 | 3.34 | 27.00 | 16.00 | ||
|
PUHZ-SHW230YKA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 4.81 | 3.51 | 3.47 | -25° | 19.00 | 23.00 | |
|
RAV-GM2803AT8P-E
BIG DI 3ph
|
TOSHIBA | Ceiling suspended | 9 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.34 | 3.61 | 3.13 | -10° | 23.50 | 12.30 |