Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(0)
BRYANT
(0)
Buderus
(0)
CARRIER
(0)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(23)
EQUATION
(0)
FUJI ELECTRIC
(2)
FUJITSU
(2)
Fujitsu Atlantic
(2)
GENERAL
(2)
GREE
(0)
GSS
(0)
HAIER
(2)
HEC
(0)
HEIWA
(0)
HISENSE
(2)
HITACHI
(1)
IVT
(0)
Inventor
(0)
KAYSUN
(0)
LG
(6)
MIDEA
(0)
MITSUBISHI ELECTRIC
(8)
Mitsubishi Heavy Industries
(17)
NORD
(0)
Nobu
(0)
PANASONIC
(9)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(2)
THERMOR
(0)
TOSHIBA
(6)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
COP from:
EER from:
Bivalent down to:
| Model | Brand | Type | Score ↓ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
FDC200VSA/FDUM100VH/FDUM100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 84 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 7.36 | 4.77 | 3.71 | 19.00 | 12.50 | ||
|
FDC200VSA-W/FDUM100VH/FDUM100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 6.57 | 4.64 | 4.01 | 20.00 | 12.50 | ||
|
FDC200VSA/FDE100VH/FDE100VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.49 | 4.70 | 3.67 | 19.00 | 12.50 | ||
|
RZA200D
RZA
|
DAIKIN | Ducted | 78 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.51 | 4.20 | 19.00 | 11.20 | |||
|
U-250PZH4E8 / S-6071PF3E(4x)
2024
|
PANASONIC | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.59 | 4.00 | 3.75 | -20° | 21.50 | 17.20 | |
|
RZA250D
RZA
|
DAIKIN | Ducted | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.69 | 4.33 | 22.00 | 12.10 | |||
|
FDC250VSA-W/FDUM125VH/FDUM125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.40 | 3.54 | 25.00 | 14.20 | ||
|
FDC250VSA/FDUM125VH/FDUM125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 75 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.15 | 4.50 | 3.59 | 24.00 | 14.20 | ||
|
U-250PZH4E8 + P‐VTVF250NC5‐PE
2025
|
PANASONIC | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
U-250PZH4E8 + P‐VTVF250PC5‐PE
2025
|
PANASONIC | Ducted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.33 | 3.95 | 3.74 | -20° | 24.18 | 18.52 | |
|
FDC200VSA-W/FDE100VH/FDE100VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.60 | 4.53 | 3.96 | 20.00 | 12.50 | ||
|
RZA250D
RZA
|
DAIKIN | Ducted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.65 | 4.10 | 22.00 | 12.10 | |||
|
RZA200D
RZA
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.32 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ducted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.32 | 4.10 | 4.10 | 19.00 | 11.20 | ||
|
FDC280VSA-W/FDUM140VH/FDUM140VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.10 | 4.23 | 3.54 | 27.00 | 16.00 | ||
|
FDC250VSA-W/FDE125VH/FDE125VH
VNA-W/VSA-W (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.20 | 4.25 | 3.53 | 25.00 | 14.20 | ||
|
RZA200D
RZA
|
DAIKIN | Ducted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.38 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 66 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.39 | 4.15 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.08 | 4.10 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.01 | 4.10 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.70 | 4.10 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.39 | 4.10 | 22.00 | 12.10 | |||
|
FDC250VSA/FDE125VH/FDE125VH
VNA/VSA (AC2 multi)
|
Mitsubishi Heavy Industries | Ceiling suspended | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 4.45 | 3.58 | 24.00 | 14.20 | ||
|
U-200PZH4E8 / S-6071PF3E(3x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
U-200PZH4E8 / S-3650PF3E(4x)
2024
|
PANASONIC | Ducted | 56 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 3.85 | 3.55 | -20° | 19.00 | 16.00 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.83 | 3.93 | 19.00 | 11.20 | |||
|
U-200PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.35 | 3.83 | 3.55 | -20° | 19.00 | 16.00 | |
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
RZA250D
RZA
|
DAIKIN | Ducted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.42 | 3.90 | 22.00 | 12.10 | |||
|
U-250PZH4E8 / S-1014PF3E(2x)
2024
|
PANASONIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.11 | 3.75 | 3.55 | -20° | 22.00 | 17.20 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.01 | 3.90 | 19.00 | 11.20 | |||
|
RZA200D
RZA
|
DAIKIN | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.01 | 3.90 | 19.00 | 11.20 | |||
|
RZA250D
RZA
|
DAIKIN | Ceiling suspended | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.10 | 22.00 | 12.10 | |||
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
FUJITSU | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOHG90LRLA/ARHG90LHTA
AOHG**L
|
GENERAL | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
ROG90LRLA/RDG90LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
AOYG90LRLA/ARYG90LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.14 | 3.92 | 3.30 | 22.00 | 18.50 | ||
|
RZA250D
RZA
|
DAIKIN | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.08 | 3.86 | 22.00 | 12.10 | |||
|
AUD200UX4RPH8/AUW200U6RZ8
Turbo Inverter R32
|
HISENSE | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 3.90 | 3.75 | -10° | 19.00 | 17.00 | |
|
PUZ-ZM200YKA2/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.62 | 3.50 | -20° | 19.00 | 18.90 | |
|
RZA200D
RZA
|
DAIKIN | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.85 | 3.82 | 19.00 | 11.20 | |||
|
PUZ-ZM200YKA3/PEA-M200LA2
P series
|
MITSUBISHI ELECTRIC | Ducted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.88 | 3.61 | 3.50 | -20° | 19.00 | 18.90 | |
|
AUD250UX4RPH8/AUW250U6RZ8
Turbo Inverter R32
|
HISENSE | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.82 | 3.90 | 3.45 | -10° | 23.00 | 17.00 | |
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.64 | 3.85 | 3.85 | 19.00 | 11.20 | ||
|
RZA200D
RZA
|
DAIKIN | Ceiling suspended | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.32 | 3.89 | 3.89 | 19.00 | 11.20 | ||
|
RAV-GM2243AT8P-E/RAV-RM2241DTP-E2
DI 3ph
|
TOSHIBA | Ducted | 40 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 3.80 | 3.24 | -10° | 19.00 | 11.40 | |
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
FUJITSU | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AOHG72LRLA/ARHG72LHTA
AOHG**L
|
GENERAL | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
ROG72LRLA/RDG72LHTA
ROG**L
|
FUJI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 | ||
|
AOYG72LRLA/ARYG72LHTA
AOYG**L
|
Fujitsu Atlantic | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.22 | 3.94 | 3.40 | 19.00 | 15.30 |