Filters · 3 active
Manufacturer:
BOSCH
HITACHI
AIRCLASS
(1)
AIRWELL
(18)
ATLANTIC
(10)
AUX
(16)
BRYANT
(2)
Buderus
(11)
CARRIER
(33)
CIAT
(9)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(8)
DAIKIN
(122)
EQUATION
(1)
FUJI ELECTRIC
(40)
FUJITSU
(93)
Fujitsu Atlantic
(50)
GENERAL
(71)
GREE
(29)
GSS
(1)
HAIER
(117)
HEC
(3)
HEIWA
(2)
HISENSE
(94)
IVT
(4)
Inventor
(29)
KAYSUN
(10)
LG
(66)
MIDEA
(181)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(23)
NORD
(15)
Nobu
(2)
PANASONIC
(66)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(45)
THERMOR
(18)
TOSHIBA
(46)
Viessmann
(4)
Vulcano
(4)
WESTPOINT
(6)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
CL2000 35 E / CL2000U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2001 35 E / CL2001U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CL3000i 35 E / CL3000iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3200iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
RAC-CJ35WHAE / RAK-CJ35PHAE
RAC-CJ-WHAE airHome 200
|
HITACHI | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 3.71 | -15° | 3.20 | 2.80 | |
|
RPIL-1.5UNE1NH / RAS-1.5UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.82 | -15° | 3.52 | 3.52 | |
|
CL5000L 35 E / CL5000iU 4CC 35 E
Climate 5000i L
|
BOSCH | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000i 35 E / CL5000iU W 35 E
Climate 5000i
|
BOSCH | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.30 | 3.93 | -10° | 3.30 | 2.60 | |
|
CL5000L 35 E / CL5000iU D 35 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
RAC-35NPE / RAI-35RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.81 | -15° | 3.50 | 2.84 | |
|
RAC-35NPE / RAD-35RPE
RAC-NPE(D)
|
HITACHI | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 3.81 | -15° | 3.50 | 2.84 | |
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL4000i 35 E / CL4000iU W 35 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
RAM-E40N2HAE / RAK-DJ15QHAE / RAK-DJ25RHAE
RAM-ENHAE
|
HITACHI | Wall mounted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.22 | 4.20 | 3.90 | -15° | 4.00 | 3.67 | |
|
CL6000iP 35 / CL6000iP W 35
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35 F
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
RAC-DJ35WHAE / RAK-DJ35RHAE
RAC-DJ-WHAE airHome 400
|
HITACHI | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.50 | 4.60 | 4.00 | -15° | 3.50 | 2.80 | |
|
CL5100i 35 HE/CL5100i W 35 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
CL6001i 35 E / CL6001iU W 35 E
Climate 6000i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
CL6102i 35 HE / CL6102i W 35 HE
Climate 6102i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
RAC-VJ35NHAE / RAI-VJ35RHAE
RAC-VJ-NHAE airHome Mono Multi Universal
|
HITACHI | Cassette | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.30 | 4.00 | -15° | 3.50 | 2.78 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 | |
|
RAM-G36N2HCE / RAK-XJ18QHBE / RAK-XJ18QHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 3.60 | 3.50 | |
|
RAM-G43N2HCE / RAK-XJ18QHBE / RAK-XJ25RHBE
RAM-GNHCE
|
HITACHI | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -10° | 4.30 | 3.50 | |
|
CL7000i 41 E / CL7000iU W 41 E
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 ES
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 EB
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
RAC-VJ42WHAE / RAK-VJ42RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 68 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.50 | 4.60 | 4.10 | -15° | 4.20 | 4.00 | |
|
RAM-G36N2HAE / RAK-XJ18QHAE / RAK-XJ18QHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 3.60 | 3.50 | |
|
RAM-G36N2HBE / RAK-XJ18QHAE / RAK-XJ18QHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 3.60 | 3.50 | |
|
RAM-G43N2HAE / RAK-XJ18QHAE / RAK-XJ25RHAE
RAM-GNHAE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 4.30 | 3.50 | |
|
RAM-G43N2HBE / RAK-XJ18QHAE / RAK-XJ25RHAE
RAM-GNHBE
|
HITACHI | Wall mounted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.40 | -15° | 4.30 | 3.50 | |
|
CL5001L 35 E / CL5001iU D 35 E
Climate 5001 L
|
BOSCH | Ducted | 71 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.50 | 4.10 | 3.71 | -10° | 3.50 | 2.60 | |
|
RAC-VJ35WHAE / RAK-VJ35RHAE
RAC-VJ-WHAE airHome 600
|
HITACHI | Wall mounted | 74 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.90 | 4.20 | -15° | 3.50 | 2.60 | |
|
CLC8001i 35 E / CLC8001i-W 35 E
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CL7100i 35 HE / CL7100i W 35 HE
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HES
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HEB
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL8100i 65 E / CL8100i-W 65 E
Climate 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.75 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HE
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 | |
|
CLC8101i 65 HE / CLC8101i-W 65 HET
Climate Class 8100i
|
BOSCH | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.50 | 5.10 | 4.62 | -25° | 3.50 | 3.20 |