Filters · 4 active
Manufacturer:
BOSCH
HEIWA
Inventor
AIRCLASS
(1)
AIRWELL
(18)
ATLANTIC
(10)
AUX
(16)
BRYANT
(2)
Buderus
(11)
CARRIER
(33)
CIAT
(9)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(8)
DAIKIN
(122)
EQUATION
(1)
FUJI ELECTRIC
(40)
FUJITSU
(93)
Fujitsu Atlantic
(50)
GENERAL
(71)
GREE
(29)
GSS
(1)
HAIER
(117)
HEC
(3)
HISENSE
(94)
HITACHI
(22)
IVT
(4)
KAYSUN
(10)
LG
(66)
MIDEA
(181)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(23)
NORD
(15)
Nobu
(2)
PANASONIC
(66)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(45)
THERMOR
(18)
TOSHIBA
(46)
Viessmann
(4)
Vulcano
(4)
WESTPOINT
(6)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
HMIS3-35-EUV1 / HMES2-35P-EUV1
ZEN3
|
HEIWA | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 2.70 | |
|
CL2000 35 E / CL2000U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
O3MVO32-12B/O3MVI32-12WiFiRB
Omnia 3 (ECO)
|
Inventor | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
L6VO32-12/L6VI32-12WF
Life PRO
|
Inventor | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
CL2001 35 E / CL2001U W 35 E
Climate 2000
|
BOSCH | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
Ν2UVO-12/Ν2UVI-12WFI
Neo
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.87 | -10° | 3.51 | 2.50 | |
|
N2VOCP-12/Ν2VICP-12WFI
Neo
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.87 | -10° | 3.51 | 2.50 | |
|
VERO-12/VERI-12WFI
Vero
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.87 | -10° | 3.51 | 2.50 | |
|
N3VO-12/N3VI-12WFI
Neo
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.87 | -10° | 3.51 | 2.50 | |
|
PFZUVO-12/PFZUVI-12WIFI
Professional Z
|
Inventor | Wall mounted | 11 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.20 | 3.00 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
O3MVO32-12F/O3MVI32-12WiFiRF
Omnia 3 (ECO)
|
Inventor | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.10 | 3.20 | -10° | 3.50 | 2.80 | |
|
CL5000M 41/2 E / CL3000iU W 26 E + CL3000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 3.75 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL6001iU W 26 E + CL6001iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.00 | 4.18 | -10° | 4.10 | 3.80 | |
|
CL5000M 41/2 E / CL5000iU W 26 E + CL5000iU W 26 E
Climate 5000 M
|
BOSCH | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.00 | 4.00 | -10° | 4.10 | 3.80 | |
|
FUTO-12/FUTI-12WFI
Futura AI
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.40 | -10° | 3.50 | 2.70 | |
|
IKUO-12/IKUI-12WFI
Ikura
|
Inventor | Wall mounted | 26 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.70 | 4.10 | 3.40 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7LI-12WiFiR
Console R32
|
Inventor | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
CL5000L 35 E / CL5000iU CN 35 E
Climate 5000i L
|
BOSCH | Console | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.30 | 4.00 | 4.00 | -10° | 3.50 | 2.60 | |
|
AR5VO-12/AR5VI-12WFI
Aria (AR5)
|
Inventor | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.10 | 3.50 | -10° | 3.50 | 2.91 | |
|
CL3000i 35 E / CL3000iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
CL3000i 35 E / CL3200iU W 35 E
Climate 3000i
|
BOSCH | Wall mounted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.00 | 4.20 | 3.71 | -10° | 3.60 | 2.50 | |
|
NRO-12/NRI-12WFI
Nura
|
Inventor | Wall mounted | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.50 | 4.20 | 3.65 | -10° | 3.50 | 2.80 | |
|
CL5000L 35 E / CL5000iU 4CC 35 E
Climate 5000i L
|
BOSCH | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7CRI-12WiFiR
Cassette R32
|
Inventor | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5000i 35 E / CL5000iU W 35 E
Climate 5000i
|
BOSCH | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.30 | 3.93 | -10° | 3.30 | 2.60 | |
|
CL5000L 35 E / CL5000iU D 35 E
Climate 5000i L
|
BOSCH | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7DI-12WiFiR
Ducted R32
|
Inventor | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
U7RS-12/V7iCRI-12WiFiR
Cassette R32
|
Inventor | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL5001L 35 E / CL5001iU 4CC 35 E
Climate 5001 L
|
BOSCH | Cassette | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
CL4000i 35 E / CL4000iU W 35 E
Climate 4000i
|
BOSCH | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.60 | 3.81 | -10° | 3.50 | 2.40 | |
|
DR2VO-12/DR2VI-12WFI
Dark
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
MFVO-12/MFVI-12WFI
Comfort
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
EMPVO-12/EMPVI-12WFI
Emperor
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
EMPVO(W)-12/EMPVI(W)-12WFI
Emperor
|
Inventor | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.81 | -10° | 3.50 | 2.80 | |
|
CL6000iP 35 / CL6000iP W 35
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
CL6000iP 35 / CL6000iP W 35 F
Climate 6000iP
|
BOSCH | Wall mounted | 57 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.25 | -10° | 3.50 | 2.50 | |
|
LEUVO-12/LEUVI-12WFI
Leon
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
LHUVO-12/LHUVI-12WFI
Leon
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
LEUVOCP-12/LEUVICP-12WFI
Leon
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
CL5100i 35 HE/CL5100i W 35 HE
Climate 5100i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
INVO-12/INVI-12WFI
Intellia
|
Inventor | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 3.75 | -10° | 3.50 | 2.60 | |
|
CL6001i 35 E / CL6001iU W 35 E
Climate 6000i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
CL6102i 35 HE / CL6102i W 35 HE
Climate 6102i
|
BOSCH | Wall mounted | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.50 | 2.40 | |
|
HMIP2-35W-EUV1 / HMEP2-35-EUV1
HYOKO2
|
HEIWA | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.00 | -10° | 3.51 | 3.20 | |
|
CL6100i 65 E / CL6100i-W 65 E
Climate 6100i
|
BOSCH | Wall mounted | 62 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.40 | 4.60 | 4.28 | -20° | 3.50 | 3.20 | |
|
CLC6101i 65 HE / CLC6101i-W 65 HE
Climate Class 6100i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.60 | 4.60 | 4.20 | -20° | 3.50 | 3.20 | |
|
CL7000i 41 E / CL7000iU W 41 E
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 ES
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 | |
|
CL7000i 41 E / CL7000iU W 41 EB
Climate 7000i
|
BOSCH | Wall mounted | 64 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.30 | -10° | 4.00 | 3.00 |