Filters · 3 active
Manufacturer:
MITSUBISHI ELECTRIC
YORK
AIRCLASS
(1)
AIRWELL
(18)
ATLANTIC
(10)
AUX
(16)
BOSCH
(42)
BRYANT
(2)
Buderus
(11)
CARRIER
(33)
CIAT
(9)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(8)
DAIKIN
(122)
EQUATION
(1)
FUJI ELECTRIC
(40)
FUJITSU
(93)
Fujitsu Atlantic
(50)
GENERAL
(71)
GREE
(29)
GSS
(1)
HAIER
(117)
HEC
(3)
HEIWA
(2)
HISENSE
(94)
HITACHI
(22)
IVT
(4)
Inventor
(29)
KAYSUN
(10)
LG
(66)
MIDEA
(181)
Mitsubishi Heavy Industries
(23)
NORD
(15)
Nobu
(2)
PANASONIC
(66)
RIELLO
(10)
Rotenso
(0)
SAMSUNG
(45)
THERMOR
(18)
TOSHIBA
(46)
Viessmann
(4)
Vulcano
(4)
WESTPOINT
(6)
Mounting:
Refrigerant:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
MUZ-HJ35VA/MSZ-HJ35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 5 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.10 | 3.80 | 3.62 | -10° | 3.10 | 2.40 | |
|
YHKF12YEEBMJO-X/YHKF12XEEBMJ-RX
Monterosa YHKF
|
YORK | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
YHKF12YEEBMJO-T/YHKF12XEEBMJ-RT
Monterosa YHKF
|
YORK | Wall mounted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 3.50 | -10° | 3.60 | 2.70 | |
|
YHKF12YEEGXFO-Y/YHKF12XEEGXF-RY
Altair YHKF
|
YORK | Wall mounted | 15 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.03 | 3.45 | -10° | 3.50 | 2.70 | |
|
MXZ-2F33VF4/MSZ-AY15VGK/MSZ-LN18VG2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 4.40 | -15° | 3.30 | 2.70 | |
|
MXZ-2F33VF5/MSZ-AY15VGK(P)2/MSZ-LN18VG3
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 17 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.00 | 4.40 | -15° | 3.30 | 2.70 | |
|
MUZ-DM35VA/MSZ-DM35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 18 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.70 | 4.10 | 3.69 | -10° | 3.10 | 2.40 | |
|
SUZ-M35VA/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 2.60 | |
|
SUZ-M35VA/SFZ-M35VA
S series
|
MITSUBISHI ELECTRIC | Floor standing | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/SFZ-M35VA2
S series
|
MITSUBISHI ELECTRIC | Floor standing | 19 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
PUZ-ZM35VKA2/PKA-M35LA2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA2/PKA-M35LAL2
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PKA-M35LA3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/PKA-M35LAL3
P series
|
MITSUBISHI ELECTRIC | Wall mounted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.94 | -11° | 3.60 | 2.40 | |
|
MXZ-2D42VA2/MSZ-SF20VA/MSZ-SF20VA
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 3.80 | 4.04 | -15° | 4.00 | 4.00 | |
|
MXZ-2D33VA/MSZ-SF15VA/MSZ-EF18VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.50 | 4.10 | 4.17 | -15° | 3.30 | 2.70 | |
|
MUZ-HR35VF/MSZ-HR35VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-DW35VF/MSZ-DW35VF
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -10° | 3.40 | 2.40 | |
|
MUZ-HR35VF2/MSZ-HR35VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 29 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.60 | -10° | 3.40 | 2.40 | |
|
SUZ-M35VA2/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.00 | 4.00 | -10° | 3.60 | 3.00 | |
|
PUZ-ZM35VKA2/PCA-M35KA2
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.40 | |
|
MXZ-2F42VF4/MSZ-AY20VGK/MSZ-AY20VGK
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.64 | 3.82 | 3.89 | -15° | 4.00 | 3.20 | |
|
MXZ-2F42VF5/MSZ-AY20VGK(P)2/MSZ-AY20VGK(P)2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 7.64 | 3.82 | 3.89 | -15° | 4.00 | 3.20 | |
|
MUZ-HR42VF/MSZ-HR42VF(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.62 | -10° | 4.20 | 2.90 | |
|
MUZ-HR42VF2/MSZ-HR42VF(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.30 | 3.62 | -10° | 4.20 | 2.90 | |
|
PUZ-ZM35VKA3/PCA-M35KA3
P series
|
MITSUBISHI ELECTRIC | Ceiling suspended | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 4.02 | -11° | 3.60 | 2.70 | |
|
SUZ-SM35VA2/PEAD-SM35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.70 | |
|
MUZ-WN35VA/MSZ-WN35VA
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.30 | 3.69 | -15° | 3.10 | 2.40 | |
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 | |
|
SUZ-SM35VA/PEAD-SM35JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
SUZ-SM35VA/PEAD-SM35JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
MXZ-2D42VA2/MSZ-EF18VE3W(B)(S)/MSZ-EF25VE3W(B)(S)
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.80 | 4.20 | 4.84 | -15° | 4.20 | 3.20 | |
|
YUKF12BYEEBMO-1/YKKF12BXEEBM-R1
Grande Cassette R32
|
YORK | Cassette | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.10 | 3.74 | -10° | 3.50 | 2.70 | |
|
MUZ-SF35VE/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.40 | 3.88 | -15° | 3.50 | 2.90 | |
|
MUZ-SF35VEH/MSZ-SF35VE3
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 47 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.20 | 4.30 | 3.88 | -20° | 3.50 | 2.90 | |
|
MUFZ-KW35VGHZ2/MFZ-KW35VGK
M series
|
MITSUBISHI ELECTRIC | Floor standing | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.00 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
YUKF12BYEEBMO-1/YEKF12BXEEBM-R1
Grande Duct R32
|
YORK | Ducted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.30 | 4.00 | 3.66 | -10° | 3.50 | 2.70 | |
|
SUZ-M35VA/SEZ-M35DA2
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA/SEZ-M35DAL2
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/SEZ-M35DA3
S series
|
MITSUBISHI ELECTRIC | Ducted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.00 | 4.10 | 3.90 | -10° | 3.50 | 2.60 | |
|
MUZ-BT35VG2/MSZ-BT35VG(K)2
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.50 | |
|
MFZ-KW35VG/MUFZ-KW35VGHZ
M series
|
MITSUBISHI ELECTRIC | Floor standing | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.10 | 4.10 | 3.55 | -25° | 3.50 | 3.60 | |
|
MUZ-BT35VG/MSZ-BT35VG(K)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 3.87 | -15° | 3.50 | 2.40 | |
|
MXZ-2HA40VF2/MSZ-HR25VF/MSZ-HR25VF
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.12 | 4.30 | 4.73 | -15° | 4.00 | 3.20 | |
|
MXZ-2HA40VF3/MSZ-HR25VF2/MSZ-HR25VF2
MXZ series
|
MITSUBISHI ELECTRIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.12 | 4.30 | 4.73 | -15° | 4.00 | 3.20 | |
|
YHKF12XEEDMH-RY / YHKF12YEEDMHO-Y
Pyrenees YHKF
|
YORK | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.30 | 4.60 | 3.80 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA/MFZ-KT35VG
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.41 | -10° | 3.50 | 2.60 | |
|
SUZ-M35VA2/MFZ-KT35VGK
S series
|
MITSUBISHI ELECTRIC | Floor standing | 58 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.60 | 4.40 | 3.41 | -10° | 3.50 | 2.60 | |
|
MUZ-EF35VEH/MSZ-EF35VE3W(B)(S)
M series
|
MITSUBISHI ELECTRIC | Wall mounted | 59 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.50 | 4.19 | -20° | 3.50 | 2.90 |