Filters · 3 active
Manufacturer:
PANASONIC
SAMSUNG
AIRCLASS
(1)
AIRWELL
(18)
ATLANTIC
(10)
AUX
(34)
BOSCH
(45)
BRYANT
(2)
Buderus
(11)
CARRIER
(35)
CIAT
(9)
COLIBRI
(2)
CONFORT AIR
(1)
Candy
(8)
DAIKIN
(122)
DE DIETRICH
(7)
EQUATION
(1)
FUJI ELECTRIC
(40)
FUJITSU
(93)
Fujitsu Atlantic
(50)
GENERAL
(71)
GREE
(33)
GSS
(1)
HAIER
(116)
HEC
(3)
HEIWA
(2)
HISENSE
(108)
HITACHI
(22)
IVT
(4)
Inventor
(29)
KAYSUN
(11)
LG
(68)
MIDEA
(181)
MITSUBISHI ELECTRIC
(100)
Mitsubishi Heavy Industries
(23)
NORD
(15)
Nobu
(2)
PITSOS
(2)
RIELLO
(10)
Rotenso
(0)
THERMOR
(18)
TOSHIBA
(46)
Viessmann
(4)
Vulcano
(4)
WESTPOINT
(6)
XTRON
(1)
YORK
(6)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
AR40H12C1AMN/AR40H12C1AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40H12C1BMN/AR40H12C1BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0AMN/AR40F12C0AMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR40F12C0BMN/AR40F12C0BMX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.60 | 2.70 | |
|
AR12TXHQASIN/AR12TXHQASIX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR12TXHQBWKN/AR12TXHQBWKX
RAC
|
SAMSUNG | Wall mounted | 6 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 6.10 | 3.90 | 3.50 | -10° | 3.78 | 2.70 | |
|
AR50F12C1BHN/AR50F12C1BHX
RAC
|
SAMSUNG | Wall mounted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.00 | 3.61 | -11° | 3.50 | 2.30 | |
|
CU-TZ42WKE / CS-TZ42WKEW
2019
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.00 | 3.73 | -15° | 4.20 | 3.60 | |
|
CU-PZ35WKE / CS-PZ35WKE
2019
|
PANASONIC | Wall mounted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.10 | 3.69 | -15° | 3.40 | 2.40 | |
|
CU-UZ35WKE / CS-UZ35WKE
2019
|
PANASONIC | Wall mounted | 27 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.70 | -15° | 3.30 | 2.40 | |
|
CU-UZ35ZKE / CS-UZ35ZKE
2023
|
PANASONIC | Wall mounted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.10 | 3.72 | -15° | 3.30 | 2.40 | |
|
AC035RXADKG/AC035RNJDKG
CAC
|
SAMSUNG | Floor standing | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.10 | 3.07 | -20° | 3.50 | 2.00 | |
|
CU-UZ35CKE / CS-UZ35CKE
2025
|
PANASONIC | Wall mounted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.72 | -15° | 3.30 | 2.40 | |
|
AR12TXFZBWKN/AR12TXFZBWKX
RAC
|
SAMSUNG | Wall mounted | 32 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.30 | 3.64 | -11° | 3.50 | 2.40 | |
|
CU-FZ35WKE / CS-FZ35WKE
2019
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.66 | -15° | 3.40 | 2.40 | |
|
CU-BZ35XKE / CS-BZ35XKE
2022
|
PANASONIC | Wall mounted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.20 | 3.69 | -15° | 3.40 | 2.40 | |
|
AC035RXADKG/AC035RN1DKG
CAC
|
SAMSUNG | Cassette | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.20 | 4.00 | 3.12 | -20° | 3.50 | 2.00 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
CU-TZ42ZKE / CS-TZ42ZKEW
2023
|
PANASONIC | Wall mounted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.73 | -15° | 4.20 | 3.60 | |
|
CU-BZ35ZKE / CS-BZ35ZKE
2023
|
PANASONIC | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 4.20 | 3.72 | -15° | 3.30 | 2.40 | |
|
AR60F12C1KWN/AR60F12C1KWX
RAC
|
SAMSUNG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
AR70F12C1DBN/AR70F12C1DBX
RAC
|
SAMSUNG | Wall mounted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
CU-TZ42CKE / CS-TZ42CKEW
2025
|
PANASONIC | Wall mounted | 37 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.10 | 3.73 | -15° | 4.20 | 3.60 | |
|
AR70H12CACBN/AR70H12CACBX
RAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.60 | 4.20 | 3.61 | -11° | 3.50 | 2.40 | |
|
AC035RXADKG/AC035TNXDKG
CAC
|
SAMSUNG | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.90 | 4.10 | 3.31 | -20° | 3.50 | 2.10 | |
|
CU-BZ35CKE / CS-BZ35CKE
2025
|
PANASONIC | Wall mounted | 38 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.20 | 3.72 | -15° | 3.30 | 2.40 | |
|
AC035BXAPKG/AC035BNJPKG
CAC HEE
|
SAMSUNG | Floor standing | 39 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.40 | 4.10 | 3.13 | -25° | 3.50 | 2.00 | |
|
U-36PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 4.15 | -15° | 3.40 | 2.40 | |
|
AR50F12C1AHN/AR50F12C1AHX
RAC
|
SAMSUNG | Wall mounted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.76 | -11° | 3.50 | 2.20 | |
|
CU-CZ35WKE / CS-CZ35WKE
2020
|
PANASONIC | Wall mounted | 44 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.30 | 4.08 | -25° | 3.50 | 3.60 | |
|
U-36PZ3E5/S-2545PK4E
2024
|
PANASONIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.40 | 4.09 | -15° | 3.50 | 2.60 | |
|
CU-RZ35WKE / CS-RZ35WKEW
2019
|
PANASONIC | Wall mounted | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.20 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
CU-Z42XKE / CS-Z42XKEW
2021
|
PANASONIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.00 | 4.20 | 3.68 | -15° | 4.20 | 3.60 | |
|
CU-CZ35ZKE / CS-CZ35ZKE
2023
|
PANASONIC | Wall mounted | 46 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.30 | 4.12 | -25° | 3.50 | 3.60 | |
|
CU-RZ35ZKE / CS-RZ35ZKEW
2023
|
PANASONIC | Wall mounted | 48 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
CU-2TZ41TBE/CS-TZ25ZKEW/CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 4.49 | -15° | 4.10 | 3.50 | |
|
AR50F15C1AHN/AR50F15C1AHX
RAC
|
SAMSUNG | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.50 | 3.47 | -11° | 4.30 | 2.70 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 50 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
CU-RZ35CKE / CS-RZ35CKEW
2025
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.70 | 4.60 | 3.81 | -15° | 3.50 | 2.80 | |
|
CU-Z35UBEA / CS-Z35UD3EAW
2017
|
PANASONIC | Ducted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.80 | 4.10 | 3.82 | -15° | 3.50 | 2.80 | |
|
CU-TZ35WKE / CS-TZ35WKEW
2019
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 4.04 | -15° | 3.50 | 2.80 | |
|
CU-TZ35ZKE / CS-TZ35ZKEW
2023
|
PANASONIC | Wall mounted | 51 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.80 | 4.60 | 4.04 | -15° | 3.50 | 2.80 | |
|
U-36PZ3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 52 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.60 | 4.50 | 4.62 | -15° | 3.60 | 2.80 | |
|
CU-Z42ZKE / CS-Z42ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42ZKE / CS-XZ42ZKEW-H
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42CKE / CS-Z42CKEW-H
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-Z42CKE / CS-XZ42CKEW-H
2025
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 7.10 | 4.30 | 3.73 | -20° | 4.20 | 3.60 | |
|
CU-2Z41TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.84 | -15° | 4.10 | 3.50 | |
|
CU-Z35UBEA / CS-Z35UB4EAW
2017
|
PANASONIC | Cassette | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.50 | 4.20 | 3.31 | -15° | 3.50 | 3.00 | |
|
CU-2TZ41CBE/CS-MTZ16CKE/CS-TZ25CKEW
2025
|
PANASONIC | Wall mounted | 54 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.20 | 4.20 | 4.07 | -15° | 4.10 | 3.50 |