Filters · 2 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(0)
ATLANTIC
(0)
AUX
(0)
BOSCH
(13)
BRYANT
(0)
Buderus
(0)
CARRIER
(5)
CIAT
(0)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(24)
EQUATION
(0)
FUJI ELECTRIC
(0)
FUJITSU
(4)
Fujitsu Atlantic
(0)
GENERAL
(4)
GREE
(0)
GSS
(0)
HAIER
(3)
HEC
(0)
HEIWA
(0)
HISENSE
(0)
HITACHI
(0)
IVT
(2)
Inventor
(1)
KAYSUN
(0)
LG
(2)
MIDEA
(8)
MITSUBISHI ELECTRIC
(12)
Mitsubishi Heavy Industries
(7)
NORD
(0)
Nobu
(0)
PANASONIC
(7)
RIELLO
(0)
Rotenso
(0)
SAMSUNG
(0)
THERMOR
(0)
TOSHIBA
(10)
Viessmann
(0)
Vulcano
(0)
WESTPOINT
(0)
YORK
(0)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
PUZ-ZM35VKA2/SLZ-M35FA2
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.40 | -11° | 3.60 | 2.40 | |
|
PUZ-ZM35VKA3/SLZ-M35FA3
S series
|
MITSUBISHI ELECTRIC | Cassette | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.50 | 4.00 | 3.71 | -11° | 3.60 | 2.40 | |
|
RZAG35B / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 45 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -10° | 3.50 | 3.10 | |
|
CU-2Z35TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 49 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 5.00 | -15° | 3.50 | 3.20 | |
|
CU-2Z41TBE/CS-Z25ZKEW/CS-TZ25ZKEW
2023
|
PANASONIC | Wall mounted | 53 ▬ near median Score 40–60 — typical for its capacity class. Why? | 8.50 | 4.10 | 4.84 | -15° | 4.10 | 3.50 | |
|
RZAG35A / FHA35A9
RZAG
|
DAIKIN | Ceiling suspended | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.40 | 4.10 | 4.10 | -20° | 3.50 | 3.10 | |
|
RZAG35B / FBA35A9
RZAG
|
DAIKIN | Ducted | 55 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.12 | 4.10 | 4.40 | -10° | 3.50 | 4.20 | |
|
AS25S2SJ1FA-3/AS25S2SJ1FA-3/2U40S2SM1FA
Super Match Multi
|
HAIER | Wall mounted | 61 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.30 | |
|
RZAG35A / FBA35A9
RZAG
|
DAIKIN | Ducted | 65 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 6.12 | 4.10 | 4.40 | -20° | 3.50 | 4.20 | |
|
AS25XCAHRA+AS25XCAHRA/2U40S2SM1FA
Super Match Multi-Tundra
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.70 | |
|
AS25XCAHRA-MB+AS25XCAHRA-MB/2U40S2SM1FA
Super Match Multi-Expert
|
HAIER | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 4.60 | 4.50 | -10° | 4.00 | 3.70 | |
|
SCM30ZS-W/SRK15ZS-WF/SRK15ZS-WF
SCM
|
Mitsubishi Heavy Industries | Wall mounted | 67 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.07 | 4.80 | 5.41 | -10° | 3.00 | 3.30 | |
|
3MXM40A9 / FTXM20R / FTXM20R
3MXM
|
DAIKIN | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.53 | 4.24 | 4.73 | -15° | 4.00 | 4.80 | |
|
3MXM40A9 / FTXM20A / FTXM20A
3MXM
|
DAIKIN | Wall mounted | 70 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.53 | 4.24 | 4.73 | -15° | 4.00 | 4.80 | |
|
3MXM40A9 / CTXM15R / FTXM25R
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
3MXM40A9 / CTXM15A / FTXM25A
3MXM
|
DAIKIN | Wall mounted | 72 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.52 | 4.39 | 5.15 | -15° | 4.00 | 4.20 | |
|
NH12SP U24A / NH12SP NS1
U24A
|
LG | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.70 | 4.60 | 4.82 | -10° | 3.50 | 3.80 | |
|
RAS-2M14G3AVG-E/RAS-B13G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.68 | -20° | 4.00 | 3.10 | |
|
38WH2M040C1A0TEE/40WHHW035D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.68 | -20° | 4.00 | 3.10 | |
|
RAS-2M14G3AVG-E/RAS-B13P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 73 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.20 | 4.70 | 4.68 | -20° | 4.00 | 3.10 | |
|
PUZ-ZM35VKA3/PLA-M35EA3
P series
|
MITSUBISHI ELECTRIC | Cassette | 76 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.70 | |
|
PUZ-ZM35VKA2/PLA-M35EA2
P series
|
MITSUBISHI ELECTRIC | Cassette | 77 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 7.30 | 4.30 | 4.61 | -11° | 3.60 | 2.50 | |
|
RAS-2M10G3AVG-E/RAS-B10G3KVSG-E+RAS-B07G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10G3KVSG-E+RAS-B10G3KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
38WH2M033C1A0TEE/40WHHW025D1A0TEE/40WHHW020D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
38WH2M033C1A0TEE/40WHHW025D1A0TEE/40WHHW025D1A0TEE
38WH-M
|
CARRIER | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10P2KVSG-E+RAS-B07P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
RAS-2M10G3AVG-E/RAS-B10P2KVSG-E+RAS-B10P2KVSG-E
Multi
|
TOSHIBA | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.60 | 4.70 | 4.71 | -20° | 3.30 | 2.70 | |
|
CLC8001i 35 E / CLC8001i-W 35 E
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ET
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ES
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
CLC8001i 35 E / CLC8001i-W 35 ER
Climate Class 8000i
|
BOSCH | Wall mounted | 79 ▲ above avg Score ≥ 60 — above average for its capacity class. Why? | 8.50 | 5.10 | 4.62 | -15° | 3.50 | 3.20 | |
|
THRVO-12/THRVI-12WFI
Thora
|
Inventor | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
MOX330-12HFN8-QRE1GW/MSOPBU-12HRFN8-QRE1GW
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
MOX330-12HFN8-OPP/MSOPP-12HRFN8
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
MOX330-12HFN8-OPP/MSOPP-12HRFN8
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
OP-12RE1H-O/OP-12RE1-I
Oasis Plus
|
MIDEA | Wall mounted | 80 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.40 | -10° | 3.50 | 2.90 | |
|
MOX330-12HFN8-QRE1GW/MSOPBU-12HRFN8-QRE1GWV
Oasis Plus
|
MIDEA | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HE
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HES
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
CL7100i 35 HE / CL7100i W 35 HEB
Climate 7100i
|
BOSCH | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
Aero 704 O / Aero 704 I
Aero 700
|
IVT | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
Aero 704 O / Aero 704 IB
Aero 700
|
IVT | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.10 | 5.10 | 4.50 | -10° | 3.40 | 3.00 | |
|
MOX330-12HFN8-QRE3GW/MSOPBU-12HRFN8-QRE3GW
Oasis Plus
|
MIDEA | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 9.20 | 5.10 | 4.71 | -10° | 3.50 | 2.10 | |
|
U-36PZH3E5 / S-3650PK3E
2021
|
PANASONIC | Wall mounted | 81 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.40 | 4.90 | 4.82 | -20° | 3.60 | 3.60 | |
|
RXTA30C / FTXTA30CB
RXTA
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.17 | 5.01 | -10° | 3.00 | 3.00 | |
|
RXTA30C / FTXTA30CW
RXTA
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.17 | 5.01 | -10° | 3.00 | 3.00 | |
|
RXTJ30A / FTXTJ30AB
RXTJ
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.17 | 5.01 | -10° | 3.00 | 3.00 | |
|
RXTJ30A / FTXTJ30AW
RXTJ
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.75 | 5.17 | 5.01 | -10° | 3.00 | 3.00 | |
|
RXTP35A / FTXTP35A
RXTP
|
DAIKIN | Wall mounted | 82 ▲ top tier Score ≥ 80 — beats most peers in this capacity class. Why? | 8.55 | 4.85 | 4.55 | -30° | 3.50 | 3.00 |