Filters · 4 active
Manufacturer:
AIRCLASS
(0)
AIRWELL
(2)
ATLANTIC
(0)
AUX
(2)
BOSCH
(3)
BRYANT
(0)
Buderus
(1)
CARRIER
(3)
CIAT
(2)
COLIBRI
(0)
CONFORT AIR
(0)
Candy
(0)
DAIKIN
(10)
EQUATION
(0)
FUJI ELECTRIC
(6)
FUJITSU
(20)
Fujitsu Atlantic
(10)
GENERAL
(10)
GREE
(2)
GSS
(0)
HAIER
(5)
HEC
(0)
HEIWA
(0)
HISENSE
(4)
HITACHI
(3)
IVT
(0)
Inventor
(2)
KAYSUN
(3)
LG
(4)
MIDEA
(10)
MITSUBISHI ELECTRIC
(17)
Mitsubishi Heavy Industries
(1)
NORD
(2)
Nobu
(0)
PANASONIC
(4)
RIELLO
(2)
Rotenso
(0)
SAMSUNG
(3)
THERMOR
(2)
TOSHIBA
(1)
Viessmann
(1)
Vulcano
(0)
WESTPOINT
(0)
YORK
(1)
Mounting:
Heating capacity:
Cooling capacity:
Heating from:
Cooling from:
Heating up to:
Cooling up to:
SCOP up to:
SEER up to:
Bivalent down to:
| Model | Brand | Type | Score ↑ Composite quality score (0–100) vs class peers — same mounting, Pdesignh ±30%. Weighted blend of SCOP, SEER, ηs,h, ηs,c, TOL and outdoor noise. Default sort. More | SEER | SCOP | COP | TOL | Cooling | Heating | |
|---|---|---|---|---|---|---|---|---|---|---|
|
UUA1 UL0 / CL12F N50
UU
|
LG | Ducted | 10 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.71 | -10° | 3.40 | 2.90 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
ROG14KATA/RDG14KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KATA/ARXG14KLLAP
ARXG**K
|
GENERAL | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOEG14KATA/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXG14KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 16 ▼ bottom tier Score 1–20 — bottom tier among peers. Why? | 5.60 | 3.80 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG12KATA/ARXG12KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
ROG12KATA/RDG12KLLAP
RDG**K
|
FUJI ELECTRIC | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG12KATA/ARXG12KLLAP
ARXG**K
|
GENERAL | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOEG12KATA/ARXG12KLLAP
ARXG**K
|
FUJITSU | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG12KATA/ARXG12KLLAP
ARXG**K
|
Fujitsu Atlantic | Ducted | 20 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.80 | 3.50 | -15° | 3.50 | 2.80 | |
|
RXM35R9 / FDXM35F9
RXM
|
DAIKIN | Ducted | 21 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.26 | 3.88 | 3.48 | -15° | 3.40 | 2.90 | |
|
M2OH-14HFN8-Q/MTIU-07HWFNX-QRD0W(GA)+MTIU-07HWFNX-QRD0W(GA)
M2OH-14HFN8-Q
|
MIDEA | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.80 | |
|
AD35S2SM9FA(H)/1U35S2SM1FA-2
R32 Super Match Plus - Duct
|
HAIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 2.70 | |
|
YDAM-035R-09M25/DDHM-035N-09M22
OASIS
|
AIRWELL | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 3.50 | 2.70 | |
|
38QUS014D8S2-1/42QSS007D8S*
Ducted
|
CARRIER | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 4.24 | -10° | 4.10 | 4.00 | |
|
AIX240HIM8-1/DC220HIM8*
Ducted
|
RIELLO | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 4.24 | -10° | 4.10 | 4.00 | |
|
38HM14VS8C-1/42HY07VS8C*
Ducted
|
CIAT | Ducted | 23 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 4.24 | -10° | 4.10 | 4.00 | |
|
CL5000M 41/2 E / CL5000iM D 21 E + CL5000iM D 21 E
Climate 5000 M
|
BOSCH | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
AC-4,1 MS / AC166i-2,1 MS D + AC166i-2,1 MS D
Logacool
|
Buderus | Ducted | 24 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.80 | 3.71 | -10° | 4.10 | 3.90 | |
|
RZAG35B / FDXM35F9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
RZAG35B / FNA35A9
RZAG
|
DAIKIN | Ducted | 25 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -10° | 3.50 | 3.50 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOHG14KBTB/ARXG14KLLAP
ARH**K
|
GENERAL | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
ROG14KBTB/RDG14KLLAP
RD**K
|
FUJI ELECTRIC | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KBTB/ARXG14KLLAP
ARXG**K
|
FUJITSU | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOYG14KBTB/ARXG14KLLAP
ARY**K
|
Fujitsu Atlantic | Ducted | 28 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.79 | -15° | 4.30 | 3.80 | |
|
AOEG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOHG14KATA/ARXH14KMTAP
ARX**K
|
GENERAL | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
AOYG14KATA/ARXH14KMTAP
ARX**K
|
FUJITSU | Ducted | 30 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.80 | 3.90 | 3.52 | -15° | 4.30 | 3.20 | |
|
UUA1 UL0 / UM12FH N10
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
UUA1 UL0 / UM12FH NA0
UU
|
LG | Ducted | 31 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 3.90 | 4.10 | -10° | 3.50 | 2.80 | |
|
AOEG12KATA/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOHG12KATA/ARXH12KMTAP
ARX**K
|
GENERAL | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG12KATA/ARXH12KMTAP
ARX**K
|
FUJITSU | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AOYG12KATA/ARXH12KMTAP
ARX**K
|
Fujitsu Atlantic | Ducted | 33 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 3.90 | 3.50 | -15° | 3.50 | 2.80 | |
|
AC035RXADKG/AC035BNLDKG
CAC
|
SAMSUNG | Ducted | 34 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.10 | 4.00 | 3.31 | -20° | 3.50 | 2.00 | |
|
SUZ-SM35VA2/PEAD-SM35JA3
P series
|
MITSUBISHI ELECTRIC | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.70 | |
|
RZAG35A / FDXM35F9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
RZAG35A / FNA35A9
RZAG
|
DAIKIN | Ducted | 35 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.90 | 3.90 | 3.50 | -20° | 3.50 | 3.50 | |
|
SUZ-SM35VA/PEAD-SM35JA
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
SUZ-SM35VA/PEAD-SM35JAL
P series
|
MITSUBISHI ELECTRIC | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 3.71 | -10° | 3.60 | 2.60 | |
|
ARXM35R9 / ADEA35A
ARXM
|
DAIKIN | Ducted | 36 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 5.75 | 4.00 | 3.97 | -15° | 3.40 | 2.90 | |
|
RPIL-1.5UNE1NH / RAS-1.5UNESNH1
Primairy R410 series
|
HITACHI | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.30 | 3.80 | 3.82 | -15° | 3.52 | 3.52 | |
|
U-36PZ3E5 / S-3650PF3E
2021
|
PANASONIC | Ducted | 40 ▼ below avg Score 20–40 — below average for its capacity class. Why? | 6.00 | 4.00 | 4.15 | -15° | 3.40 | 2.40 | |
|
UUA1 UL0 / UL12FH N50
UU
|
LG | Ducted | 42 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.71 | -10° | 3.40 | 2.90 | |
|
RXM35R9 / FNA35A9
RXM
|
DAIKIN | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 5.70 | 4.05 | 3.48 | -15° | 3.40 | 2.90 | |
|
AD35S2SS1FA/1U35S2SM1FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.73 | -10° | 3.50 | 3.00 | |
|
AD35S2SS1FA(H)/1U35S2SM1FA-2
R32 Super Match Unitary - Duct
|
HAIER | Ducted | 43 ▬ near median Score 40–60 — typical for its capacity class. Why? | 6.10 | 4.00 | 3.73 | -10° | 3.50 | 3.00 |